Pattern Electroretinograms in Preperimetric and Perimetric Glaucoma

被引:23
|
作者
Jung, Kyoung In [1 ]
Jeon, Sooji [1 ]
Shin, Da Young [1 ]
Lee, Jiyun [1 ]
Park, Chan Kee [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol, Coll Med, 222 Banpo Daero, Seoul 137701, South Korea
基金
新加坡国家研究基金会;
关键词
NERVE-FIBER LAYER; VISUAL-FIELD LOSS; PHOTOPIC NEGATIVE RESPONSE; GANGLION-CELL FUNCTION; INNER PLEXIFORM LAYER; PREDICTIVE-VALUE; DOMAIN; MATRIX; ONSET; HEAD;
D O I
10.1016/j.ajo.2020.02.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate whether visual function can be graded in detail using pattern electroretinogram (PERG) in preperimetric to perimetric glaucoma. DESIGN: Cross-sectional observational study. METHODS: Twenty-six normal subjects, 113 preperimetric glaucoma patients (which included glaucoma suspect patients), and 52 early perimetric glaucoma patients with a mean deviation (MD) > - 10 dB were included. Structural and functional measurements were performed using spectral-domain optical coherence tomography and a commercial ERG stimulator, respectively. RESULTS: The average retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIPL) thickness were thinnest in the perimetric group, followed by the preperimetric group and the control group (P < .001). PERG N95 amplitude was the largest in the control group, followed by the preperimetric group and the perimetric group (P < .001). Among the preperimetric glaucoma patients, presence of the RNFL defect was associated with lower PERG N95 amplitude (P = .013). The N95 amplitude showed a significant relationship with average RNFL thickness (r = 0.336, P < .001) and GCIPL thickness (r = 0.376, P < .001). In the preperimetric group with the RNFL defect, the N95 amplitude showed larger areas under the receiver operating characteristic curve (0.779) than the MD (0.533, P = .005). CONCLUSIONS: PERG N95 amplitudes decreased from the control to preperimetric glaucoma group and were reduced more in perimetric glaucoma. The functional assessment for detecting early glaucomatous damage could be complemented by PERG N95 amplitude. Usefulness of PERG parameters except N95 amplitude seemed to be limited in a clinical setting because of relatively low diagnostic performance in preperimetric glaucoma. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:118 / 126
页数:9
相关论文
共 50 条
  • [11] Detection of Functional Change in Preperimetric and Perimetric Glaucoma Using 10-2 Matrix Perimetry
    Jung, Kyoung In
    Park, Chan Kee
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 182 : 35 - 44
  • [12] Asymmetry analysis of optical coherence tomography angiography macular perfusion density measurements in preperimetric and perimetric glaucoma
    Pei-Yao Chang
    Jiun-Yi Wang
    Jia-Kang Wang
    Shih-Cheng Yeh
    Shu-Wen Chang
    [J]. Scientific Reports, 10
  • [13] Asymmetry analysis of optical coherence tomography angiography macular perfusion density measurements in preperimetric and perimetric glaucoma
    Chang, Pei-Yao
    Wang, Jiun-Yi
    Wang, Jia-Kang
    Yeh, Shih-Cheng
    Chang, Shu-Wen
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [14] Preperimetric glaucoma study 1: Analysis of visual field defect in preperimetric glaucoma
    Aizawa, Naoko
    Shiga, Yukihiro
    Tsuda, Satoru
    Omodaka, Kazuko
    Yokoyama, Yu
    Yasui, Tomoki
    Kato, Keiichi
    Nakazawa, Toru
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [15] Pattern Electroretinogram association with RNFLT and ONH anatomy in preperimetric glaucoma patients
    Derr, Peter H.
    Tirsi, Andrew
    Soria, Jaime
    Djougarian, Anna
    Lee, Jung Min
    Schwartz, Lukas A.
    Park, Sung Chul
    Garcia, Alberto Gonzalez
    Tello, Celso
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [16] Pattern electroretinogram losses underlying perimetric losses in early glaucoma
    Scullica, L
    Falsini, B
    Salgarello, T
    Colotto, A
    Scullica, MG
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 : 27 - 28
  • [17] PATTERN ELECTRORETINOGRAMS FROM HEMIFIELDS IN NORMAL SUBJECTS AND PATIENTS WITH GLAUCOMA
    GRAHAM, SL
    WONG, VAT
    DRANCE, SM
    MIKELBERG, FS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (09) : 3347 - 3356
  • [18] Ganglion Cell-Inner Plexiform Layer Thickness of High Definition Optical Coherence Tomography in Perimetric and Preperimetric Glaucoma
    Begum, Viquar U.
    Addepalli, Uday K.
    Yadav, Ravi K.
    Shankar, Kalmuri
    Senthil, Sirisha
    Garudadri, Chandra S.
    Rao, Harsha L.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) : 4768 - 4775
  • [19] Pattern Electroretinograms During the Cold Pressor Test in Normals and Glaucoma Patients
    La Mancusa, Antonia
    Horn, Folkert K.
    Kremers, Jan
    Huchzermeyer, Cord
    Rudolph, Michael
    Juenemann, Anselm
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) : 2173 - 2179
  • [20] PATTERN-REVERSAL ELECTRORETINOGRAMS IN GLAUCOMA, AMBLYOPIA AND MULTIPLE-SCLEROSIS
    PERSSON, H
    WANGER, P
    [J]. ACTA OPHTHALMOLOGICA, 1985, 63 (04): : 473 - 473