Lumbar Artery Pseudoaneurysm Caused by a Gunther Tulip Inferior Vena Cava Filter

被引:12
|
作者
Skeik, Nedaa [1 ]
McEachen, James C.
Stockland, Andrew H.
Wennberg, Paul W. [1 ]
Shepherd, Roger F. J. [1 ]
Shields, Raymond C. [1 ]
Andrews, James C.
机构
[1] Mayo Clin, Cardiovasc Dept, Rochester, MN 55905 USA
关键词
IVC filters; lumbar artery pseudoaneurysm; CT scan; endovascular embolization; HEMORRHAGE; SECONDARY;
D O I
10.1177/1538574411419373
中图分类号
R61 [外科手术学];
学科分类号
摘要
Inferior vena cava (IVC) filters are widely used to decrease the risk of pulmonary embolism in patients with contraindications to anticoagulation. Complications include local hematoma, access site deep venous thrombosis (DVT), filter migration and embolization, leg penetration through the IVC wall, IVC occlusion, and filter fracture with embolization. Other rare complications include leg penetration into adjacent organs including duodenum and ureter. Lumbar artery pseudoaneurysms are rare and may be spontaneous, iatrogenic, or traumatic. To date, there have been 3 case reports of lumbar artery pseudoaneurysms caused by IVC filters. We present an additional case of a lumbar artery pseudoaneurysm caused by a Gunther Tulip IVC filter treated successfully with selective embolization.
引用
收藏
页码:756 / 760
页数:5
相关论文
共 50 条
  • [11] Repeated Gunther Tulip inferior vena cava filter repositioning to prolong implantation time
    Tay, KH
    Martin, ML
    Fry, PD
    Webb, JG
    Machan, LS
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (05) : 509 - 512
  • [12] Evaluation of Retrievability of the Gunther Tulip Vena Cava Filter
    Takuji Yamagami
    Takeharu Kato
    Tatsuya Hirota
    Rika Yoshimatsu
    Tomohiro Matsumoto
    Tsunehiko Nishimura
    CardioVascular and Interventional Radiology, 2007, 30 : 226 - 231
  • [13] Evaluation of retrievability of the Gunther tulip vena cava filter
    Yamagami, Takuji
    Kato, Takeharu
    Hirota, Tatsuya
    Yoshimatsu, Rika
    Matsumoto, Tomohiro
    Nishimura, Tsunehiko
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 226 - 231
  • [14] Right atrial migration and percutaneous retrieval of a Gunther Tulip inferior vena cava filter
    Bochenek, KM
    Aruny, JE
    Tal, MG
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (09) : 1207 - 1209
  • [15] Serial repositioning of a Gunther tulip retrievable inferior vena cava filter in a pediatric patient
    Haider, EA
    Rosen, JC
    Torres, C
    Valenti, DA
    PEDIATRIC RADIOLOGY, 2005, 35 (11) : 1135 - 1138
  • [16] Lumbar artery pseudoaneurysm in a patient with inferior vena cava filter and history of strenuous physical exercise
    Tsekouras, Nikolaos
    Whalen, Ralph C.
    Comerota, Anthony J.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (03) : 796 - 799
  • [17] Introducer Curving Technique for the Prevention of Tilting of Transfemoral Gunther Tulip Inferior Vena Cava Filter
    Xiao, Liang
    Huang, De-sheng
    Shen, Jing
    Tong, Jia-jie
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (04) : 483 - 491
  • [18] Use of rigid bronchoscopic forceps in the difficult retrieval of the Gunther Tulip inferior vena cava filter
    Burke, Charles T.
    Dixon, Robert G.
    Stavas, Joseph M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (10) : 1319 - 1323
  • [19] The Gunther Tulip retrievable filter:: Prolonged temporary filtration by repositioning within the inferior vena cava
    de Gregorio, MA
    Gamboa, P
    Gimeno, MJ
    Madariaga, B
    Tobío, R
    Herrera, M
    Medrano, J
    Mainar, A
    Alfonso, R
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (10) : 1259 - 1265
  • [20] Gunther Tulip inferior vena cava filter retrieval using a bidirectional loop-snare technique
    Ross, Jordan
    Allison, Stephen
    Vaidya, Sandeep
    Monroe, Eric
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2016, 22 (05) : 460 - 462