Prevention of Catheter-Related Blood Stream Infection: Back to Basics?

被引:14
|
作者
Cherry-Bukowiec, Jill R. [1 ]
Denchev, Krassimir [2 ]
Dickinson, Sharon [3 ]
Chenoweth, Carol E. [4 ]
Zalewski, Christy [5 ]
Meldrum, Craig [6 ]
Sihler, Kristen C. [1 ]
Brunsvold, Melissa E. [1 ]
Papadimos, Thomas J. [7 ]
Park, Pauline K. [1 ]
Napolitano, Lena M. [1 ]
机构
[1] Univ Michigan, Dept Acute Care Surg, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Anesthesiol, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Surg Intens Care Unit, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Internal Med, Ann Arbor, MI 48109 USA
[5] Univ Michigan, Dept Infect Control, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Dept Clin Affairs, Ann Arbor, MI 48109 USA
[7] Ohio State Univ, Dept Anesthesiol, Columbus, OH 43210 USA
关键词
CENTRAL VENOUS CATHETERS; CLINICAL EFFECTIVENESS; ANTIINFECTIVE AGENTS; EDUCATION-PROGRAM; COATED CATHETERS; ACUTE PHYSIOLOGY; COST;
D O I
10.1089/sur.2009.082
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Central venous catheter (CVC)-related infections are a substantial problem in the intensive care unit (ICU). Our infection control team initiated the routine use of antiseptic-coated (chlorhexidine-silver sulfadiazine; Chx-SS) CVCs in our adult ICUs to reduce catheter-associated (CA) and catheter-related (CR) blood stream infection (BSI) as we implemented other educational and best practice standardization strategies. Prior randomized studies documented that the use of Chx-SS catheters reduces microbial colonization of the catheter compared with an uncoated standard (Std) CVC but does not reduce CR-BSI. We therefore implemented the routine use of uncoated Std CVCs in our surgical ICU (SICU) and examined the impact of this change. Hypothesis: The use of uncoated Std CVCs does not increase CR-BSI rate in an SICU. Methods: Prospective evaluation of universal use of uncoated Std CVCs, implemented November 2007 in the SICU. The incidences of CA-BSI and CR-BSI were compared during November 2006-October 2007 (universal use of Chx-SS CVCs) and November 2007-October 2008 (universal use of Std CVCs) by t-test. The definitions of the U. S. Centers for Disease Control and Prevention were used for CA-BSI and CR-BSI. Patient data were collected via a dedicated Acute Physiology and Chronic Health Evaluation (APACHE) III coordinator for the SICU. Results: Annual use of CVCs increased significantly in the last six years, from 3,543 (2001) to 5,799 (2006) total days. The APACHE III scores on day 1 increased from a mean of 54.4 in 2004 to 55.6 in 2008 (p = 0.0010; 95% confidence interval [CI] 1.29-5.13). The mean age of the patients was unchanged over this period, ranging from 58.2 to 59.6 years. The Chx-SS catheters were implemented in the SICU in 2002. Data regarding the specific incidence of CR-BSI were collected beginning at the end of 2005, with mandatory catheter tip cultures when CVCs were removed. Little difference was identified in the incidence of BSI between the interval with universal Chx-SS use and that with Std CVC use. (Total BSI 0.7 vs. 0.8 per 1,000 catheter days; CA-BSI 0.5 vs. 0.8 per 1,000 catheter days; CR-BSI 0.2 vs. 0 per 1,000 catheter days.) No difference was seen in the causative pathogens of CA-BSI or CR-BSI. Conclusion: Eliminating the universal use of Chx-SS-coated CVCs in an SICU with a low background incidence of CR-BSIs did not result in an increase in the rate of CR-BSIs. This study documents the greater importance of adherence to standardization of the processes of care related to CVC placement than of coated CVC use in the reduction of CR-BSI.
引用
收藏
页码:27 / 32
页数:6
相关论文
共 50 条
  • [31] Catheter-related blood stream infections (CRBSI): a European view
    Vanholder, Raymond
    Canaud, Bernard
    Fluck, Richard
    Jadoul, Michel
    Labriola, Laura
    Marti-Monros, Anna
    Tordoir, Jan
    Van Biesen, Wim
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2010, 25 (06) : 1753 - 1756
  • [32] Improving catheter-related blood stream infection in haemodialysis patients using a practice development framework
    Chu, Ginger
    Adams, Kelly
    Crawford, Sarah
    RENAL SOCIETY OF AUSTRALASIA JOURNAL, 2013, 9 (01) : 16 - 21
  • [33] AN ANALYSIS OF THE INCREMENTAL DAILY RISK OF CATHETER-RELATED BLOOD STREAM INFECTION IN A PARENTERAL NUTRITION POPULATION
    Conrick-Martin, I.
    McGovern, M. E.
    Boner, K. S.
    Bourke, J.
    Fitzgerald, E.
    Hone, R.
    Lynch, M.
    Phelan, D.
    Walshe, C. M.
    INTENSIVE CARE MEDICINE, 2013, 39 : S335 - S335
  • [34] Catheter-related blood stream infection caused by Dermacoccus barathri, representing the first case of Dermacoccus infection in humans
    Takahashi, Nobuhiro
    Shinjoh, Masayoshi
    Tomita, Hirofumi
    Fujino, Akihiro
    Sugita, Kayoko
    Katohno, Yasuhiro
    Kuroda, Tatsuo
    Kikuchi, Ken
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2015, 21 (08) : 613 - 616
  • [35] Role of antibiotic prophylaxis for the prevention of intravascular catheter-related infection
    Carratalà, J
    CLINICAL MICROBIOLOGY AND INFECTION, 2001, 7 : 83 - 90
  • [36] Prevention of catheter-related infections
    Schwaiger, K.
    Christ, M.
    Battegay, M.
    Widmer, A.
    ANAESTHESIST, 2012, 61 (10): : 915 - 922
  • [37] Prevention of catheter-related infection: Evidence-based medicine
    Donald P. Levine
    Current Infectious Disease Reports, 2009, 11 (4) : 255 - 256
  • [38] Prevention of catheter-related infections
    Schwaiger, K.
    Christ, M.
    Battegay, M.
    Widmer, A.
    INTERNIST, 2012, 53 (06): : 705 - 713
  • [39] ORGANIZATIONAL COMMUNICATION EFFORTS FOR THE PREVENTION OF CATHETER RELATED BLOOD STREAM INFECTION FROM HEMODIALYSIS
    Rattan, J. S.
    Rangachari, P.
    Nahman, N. S.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (01) : 414 - 414
  • [40] Does good hygiene compliance reduce catheter-related blood stream infection? A single centre experience
    Chu, Ginger
    Adams, Kelly
    Fogarty, Gemma
    Holliday, Liz
    RENAL SOCIETY OF AUSTRALASIA JOURNAL, 2018, 14 (02) : 65 - 69