A Ratiometric Readout Circuit for Thermal-Conductivity-Based Resistive CO2 Sensors

被引:18
|
作者
Cai, Zeyu [1 ]
van Veldhoven, Robert H. M. [2 ]
Falepin, Annelies [3 ,4 ]
Suy, Hilco [2 ,6 ]
Sterckx, Eric [3 ,5 ]
Bitterlich, Christian [7 ]
Makinwa, Kofi A. A. [1 ]
Pertijs, Michiel A. P. [1 ]
机构
[1] Delft Univ Technol, Elect Instrumentat Lab, NL-2628 CD Delft, Netherlands
[2] NXP Semicond, NL-5656 AE Eindhoven, Netherlands
[3] NXP Semicond, B-3001 Leuven, Belgium
[4] Materialise, B-3001 Leuven, Belgium
[5] Telit Automot, B-3001 Leuven, Belgium
[6] BL Environm Sensors, Ams, NL-5656 AE Eindhoven, Netherlands
[7] BL Environm Sensors, Ams, D-72770 Reutlingen, Germany
关键词
CO2; sensor; gas sensor; thermal conductivity; thermal resistance; resistive sensor; RDC; ratiometric; delta sigma modulator; GAS; INTERFACE;
D O I
10.1109/JSSC.2016.2587861
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports a readout circuit for a resistive CO2 sensor, which operates by measuring the CO2-dependent thermal conductivity of air. A suspended hot-wire transducer, which acts both as a resistive heater and temperature sensor, exhibits a CO2-dependent heat loss to the surrounding air, allowing CO2 concentration to be derived from its temperature rise and power dissipation. The circuit employs a dual-mode incremental delta-sigma ADC to digitize these parameters relative to those of an identical, but isolated, reference transducer. This ratiometric approach results in a measurement that does not require precision voltage or power references. The readout circuit uses dynamically-swapped transducer pairs to cancel their baseline-resistance, so as to relax the required dynamic range of the ADC. In addition, dynamic element matching (DEM) is used to bias the transducer pairs at an accurate current ratio, making the measurement insensitive to the precise value of the bias current. The readout circuit has been implemented in a standard 0.16 mu m CMOS technology. With commercial resistive micro-heaters, a CO2 sensing resolution of about 200 ppm (1s) was achieved in a measurement time of 30 s. Similar results were obtained with CMOS-compatible tungsten-wire transducers, paving the way for fully-integrated CO2 sensors for air-quality monitoring.
引用
收藏
页码:2463 / 2474
页数:12
相关论文
共 50 条
  • [21] A fast-readout interface circuit for high-value and wide-range resistive chemical sensors
    Depari, A.
    Flammini, A.
    Marioli, D.
    Sisinni, E.
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [22] Thermal Recovery Characteristics of a CO2 Mixture Gas Circuit Breaker
    Oh, Yeon-Ho
    Song, Ki-Dong
    Lee, Hae-June
    Hahn, Sung-Chin
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2016, 11 (04) : 969 - 973
  • [23] MEASUREMENTS OF THERMAL-CONDUCTIVITY DIVERGENCE IN SUPERCRITICAL REGION OF CO2
    MURTHY, MLR
    SIMON, HA
    PHYSICAL REVIEW A, 1970, 2 (04): : 1458 - &
  • [24] Are there "CO2 sensors" in the lung?
    Lee, LY
    Lin, RL
    Ho, CY
    Gu, Q
    Hong, JL
    ARTERIAL CHEMORECEPTORS, 2006, 580 : 281 - 292
  • [25] Highly Selective Multiple Gases Detection Using a Thermal-Conductivity-Based MEMS Resonator and Machine Learning
    Yaqoob, Usman
    Lenz, Wagner B.
    Alcheikh, Nouha
    Jaber, Nizar
    Younis, Mohammad, I
    IEEE SENSORS JOURNAL, 2022, 22 (20) : 19858 - 19866
  • [26] Correction experimental values of the thermal conductivity of N2O and CO2 for thermal accommodation
    Zimina, NK
    Smygalina, LP
    ZHURNAL FIZICHESKOI KHIMII, 1996, 70 (11): : 1941 - 1944
  • [27] CO2 operation of an active target detector readout based on THGEM.
    Ayyad, Y.
    Cortesi, M.
    Mittig, W.
    Bazin, D.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [28] QCM Sensors Based on PEI Films for CO2 Detection
    Guang-Zhong Xie
    Ting Kang
    Yong Zhou
    Tao Xie
    Hui-Ling Tai
    Ya-Dong Jiang
    Journal of Electronic Science and Technology, 2015, (02) : 181 - 187
  • [29] QCM sensors based on PEI films for CO2 detection
    Xie, Guang-Zhong
    Kang, Ting
    Zhou, Yong
    Xie, Tao
    Tai, Hui-Ling
    Jiang, Ya-Dong
    Journal of Electronic Science and Technology, 2015, 13 (02) : 181 - 187
  • [30] RARE-EARTH BASED CHEMORESISTIVE CO2 SENSORS
    Suzuki, Takuya
    Sackmann, Andre
    Oprea, Alexandru
    Weimar, Udo
    Barsan, Nicolae
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 1309 - 1312