Parafoveal Retinal Vessel Density Assessment by Optical Coherence Tomography Angiography in Healthy Eyes

被引:21
|
作者
Arya, Malvika [1 ]
Rebhun, Carl B. [1 ]
Alibhai, A. Yasin [1 ]
Chen, Xuejing [1 ]
Moreira-Neto, Carlos [2 ]
Baumal, Caroline R. [1 ]
Reichel, Elias [1 ]
Witkin, Andre J. [1 ]
Duker, Jay S. [1 ]
Sadda, SriniVas R. [3 ]
Waheed, Nadia K. [1 ]
机构
[1] Tufts Med Ctr, New England Eye Ctr, 260 Tremont St,Biewend Bldg,9-11th Floor, Boston, MA 02116 USA
[2] Hosp Olhos Parana, Curitiba, Parana, Brazil
[3] Univ Calif Los Angeles, David Geffen Sch Med, Doheny Eye Inst, Los Angeles, CA 90095 USA
来源
关键词
FOVEAL AVASCULAR ZONE; SWEPT-SOURCE; CHOROIDAL NEOVASCULARIZATION; QUANTITATIVE-ANALYSIS; CAPILLARY DENSITY; RETINOPATHY; REPRODUCIBILITY; OCCLUSION; IMPACT;
D O I
10.3928/23258160-20180814-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To assess variability in vessel density (VD) measurements across three optical coherence tomography angiography (OCTA) devices to identify a methodology that offers the least amount of variation in VD, and to assess the effect of averaging of multiple scans on VD variability. PATIENTS AND METHODS: Fifteen eyes of eight healthy individuals were imaged consecutively on three OCTA devices. Segmentations at the superficial, deep, and full retinal layers were generated. Repeat scans for each retinal layer were registered and averaged to generate one OCTA image. Two different automated thresholding techniques were used to calculate vessel area density (VAD) from binarized images and vessel skeleton density (VSD) from skeletonized images. Vessel length, a linear measure of the combined lengths of vessels, was calculated. Foveal avascular zone (FAZ) area was measured. RESULTS: All three OCTA devices were significantly different (P < .0001). This finding remained after averaging images (P < .0001). VSD was more repeatable within a device but less reproducible across devices. Conversely, VAD demonstrated less repeatability but greater reproducibility. Differences in VSD between devices were systematic and attributable to differences in resolution. Vessel length, unaffected by resolution, demonstrated no significant differences between the devices (P > .107). There was no significant difference in FAZ area across devices (P = .51). After averaging images, VD was significantly different from the single images for each device and plexus (P < .05) but remained within 1% of the value of a single scan. CONCLUSIONS: OCTA devices show variability in VD for healthy individuals. With greater repeatability, VSD appeared useful for following a patient on one device. VAD and vessel length seemed ideal for comparing vessel parameters between OCTA devices. After averaging multiple scans, VSD remained within 1% of a single scan, for which clinical significance remains to be determined. Caution is advised when comparing quantitative analyses across OCTA devices.
引用
收藏
页码:S5 / S17
页数:13
相关论文
共 50 条
  • [21] In Vivo Assessment of Macular Vascular Density in Healthy Human Eyes Using Optical Coherence Tomography Angiography
    Shahlaee, Abtin
    Samara, Wasim A.
    Hsu, Jason
    Say, Emil Anthony T.
    Khan, M. Ali
    Sridhar, Jayanth
    Hong, Bryan K.
    Shields, Carol L.
    Ho, Allen C.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 165 : 39 - 46
  • [22] Impact of Pupil Dilation on Optical Coherence Tomography Angiography Retinal Microvasculature in Healthy Eyes
    Villatoro, George
    Bowd, Christopher
    Proudfoot, James A.
    Manalastas, Patricia I. C.
    Nguyen, Khoa D.
    Hou, Huiyuan
    Penteado, Rafaella C.
    Li, Andrew J.
    Moghimi, Sasan
    Ghahari, Elham
    Weinreb, Robert N.
    Zangwill, Linda M.
    JOURNAL OF GLAUCOMA, 2020, 29 (11) : 1025 - 1029
  • [23] Repeatability of vessel density measurements of optical coherence tomography angiography in normal and glaucoma eyes
    Venugopal, Jayasree P.
    Rao, Harsha L.
    Weinreb, Robert N.
    Pradhan, Zia S.
    Dasari, Srilakshmi
    Riyazuddin, Mohammed
    Puttiah, Narenda K.
    Rao, Dhanraj A. S.
    Devi, Sathi
    Mansouri, Kaweh
    Webers, Carroll A. B.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (03) : 352 - 357
  • [24] REPRODUCIBILITY OF VESSEL DENSITY MEASUREMENT WITH OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN EYES WITH AND WITHOUT RETINOPATHY
    You, Qisheng
    Freeman, William R.
    Weinreb, Robert N.
    Zangwill, Linda
    Manalastas, Patricia I. C.
    Saunders, Luke J.
    Nudleman, Eric
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (08): : 1475 - 1482
  • [25] The repeatability of superficial retinal vessel density measurements in eyes with long axial length using optical coherence tomography angiography
    Li, Mengyang
    Jin, Enzhong
    Dong, Chongya
    Zhang, Chuan
    Zhao, Mingwei
    Qu, Jinfeng
    BMC OPHTHALMOLOGY, 2018, 18
  • [26] The repeatability of superficial retinal vessel density measurements in eyes with long axial length using optical coherence tomography angiography
    Mengyang Li
    Enzhong Jin
    Chongya Dong
    Chuan Zhang
    Mingwei Zhao
    Jinfeng Qu
    BMC Ophthalmology, 18
  • [27] Investigation of retinal capillary plexuses in normal eyes using optical coherence tomography angiography axial vessel density analysis
    Hirano, Takao
    Chanwimol, Karntida
    Weichsel, Julian
    Tepelus, Tudor Cosmin
    Sadda, Srinivas R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [28] The Repeatability of Superficial Retinal Vessel Density Measurements in Eyes with Long Axial Length Using Optical Coherence Tomography Angiography
    Li, Mengyang
    Zhang, Chuan
    Zhao, Mingwei
    Qu, Jinfeng
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [30] Evaluation of retinal vessel and perfusion density in migraine patients by optical coherence tomography angiography
    He, Na
    Shao, Huijun
    He, Jialing
    Zhang, Xiangxiang
    Ye, Danni
    Lv, Zhigang
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2022, 40