Dimensional analysis of critical heat flux in subcooled water flow under one-side heating conditions for fusion application

被引:53
|
作者
Boscary, J
Araki, M
Schlosser, J
Akiba, M
Escourbiac, F
机构
[1] Japan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 31101, Japan
[2] CEA Cadarache, EURATOM Assoc CEA, Dept Rech Fus Controlee, F-13108 St Paul Les Durance, France
[3] TEMA Energie, F-13009 Marseille, France
关键词
plasma facing component; critical heat flux; subcooled boiling water flow; one-side heating;
D O I
10.1016/S0920-3796(98)00387-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Critical heat flux (CHF) experiments have been carried out to design a high performance cooling device with pressurized subcooled water flow under one-side heating conditions for plasma facing components. Swirl, screw and hypervapotron tubes are the most efficient geometries to remove high incident heat fluxes. A dimensional analysis shows that CHF phenomenon can be featured by dimensionless groups that are the critical Boiling, the Eckert and the Reynolds numbers, the mass enthalpic quality and the ratio between liquid and vapor densities. CHF for uniformly heated smooth tubes, the maximum wall heat flue for smooth and for swirl tubes under one-side heating conditions are predicted with a reasonable accuracy by correlating these five dimensionless groups. An enhancement factor featuring the difference between one-side and uniform heating is also introduced. CHF occurrence under one-side heating is characterized by a normalized temperature, ratio between the maximal wall temperature and the onset of nucleate boiling temperature, which only depends on the pressure. According to finite element calculations performed for smooth and swirl tubes, temperature and heat flux are distributed along the inner wall of the cooling channel under one-side heating conditions. These distributions are characterized by two dimensionless numbers for each geometry: a peaking factor, which is the ratio between the maximal heat flux at the inner wall of the cooling channel and the incident heat flux, and a full width angle at half maximum of wall heat flux at the inner wall of the cooling channel. This study draws the dimensionless groups featuring CHF phenomenon not only under uniform heating, but also under one-side heating, which involve additional normalized parameters. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:147 / 171
页数:25
相关论文
共 50 条
  • [41] Critical Heat Flux(CHF) Correlations for Subcooled Water Flow Boiling at High Pressure and High Heat Flux
    LIU Ping
    GUO Yusheng
    DING Wenlong
    TANG Mingyun
    SONG Yuntao
    PENG Xuebing
    JI Jiadong
    CHEN Qinghua
    MAO Xin
    JournalofThermalScience, 2021, 30 (01) : 279 - 293
  • [42] Forced convective and sub-cooled flow boiling heat transfer in a hypervapotron heat sink under one-side heating condition
    Lim, Ji Hwan
    Park, Minkyu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 186
  • [43] Heat transfer and critical heat flux of subcooled water flow boiling in a HORIZONTAL circular tube
    Hata, K.
    Shirai, Y.
    Masuzaki, S.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 : 844 - 857
  • [44] Influence of heating rate on subcooled flow boiling critical heat flux in a short vertical tube
    Hata, K
    Shiotsu, M
    Noda, N
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2006, 49 (02) : 309 - 317
  • [45] Numerical simulation on the flow and heat transfer characteristics in the one-side heating helically coiled tubes
    Niu, Xiaojuan
    Luo, Shuaishuai
    Fan, Liang-Liang
    Zhao, Liang
    APPLIED THERMAL ENGINEERING, 2016, 106 : 579 - 587
  • [46] Investigation of Heat Transfer in Microchannel with One-Side Heating Condition Using Numerical Analysis
    Choi, Chi-woong
    Huh, Cheol
    Kim, Dongeok
    Kim, Moo Hwan
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2007, 31 (12) : 986 - 993
  • [47] A PHENOMENOLOGICAL MODEL FOR PREDICTION OF CRITICAL HEAT-FLUX UNDER HIGHLY SUBCOOLED CONDITIONS
    WEISMAN, J
    ILESLAMLOU, S
    FUSION TECHNOLOGY, 1988, 13 (04): : 654 - 659
  • [48] Measurements of three-dimensional, local subcooled flow boiling heat flux and related critical heat flux for PFCs
    Boyd, RD
    Cofie, P
    Ekhlassi, A
    FUSION TECHNOLOGY, 2001, 39 (02): : 856 - 862
  • [49] SUBCOOLED WATER-FLOW BOILING EXPERIMENTS UNDER UNIFORM HIGH HEAT-FLUX CONDITIONS - COMMENT
    WEISMAN, J
    FUSION TECHNOLOGY, 1988, 14 (03): : 1418 - 1418
  • [50] SUBCOOLED WATER-FLOW BOILING AT 1.66 MPA UNDER UNIFORM HIGH HEAT-FLUX CONDITIONS
    BOYD, RD