Dimensional analysis of critical heat flux in subcooled water flow under one-side heating conditions for fusion application

被引:53
|
作者
Boscary, J
Araki, M
Schlosser, J
Akiba, M
Escourbiac, F
机构
[1] Japan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 31101, Japan
[2] CEA Cadarache, EURATOM Assoc CEA, Dept Rech Fus Controlee, F-13108 St Paul Les Durance, France
[3] TEMA Energie, F-13009 Marseille, France
关键词
plasma facing component; critical heat flux; subcooled boiling water flow; one-side heating;
D O I
10.1016/S0920-3796(98)00387-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Critical heat flux (CHF) experiments have been carried out to design a high performance cooling device with pressurized subcooled water flow under one-side heating conditions for plasma facing components. Swirl, screw and hypervapotron tubes are the most efficient geometries to remove high incident heat fluxes. A dimensional analysis shows that CHF phenomenon can be featured by dimensionless groups that are the critical Boiling, the Eckert and the Reynolds numbers, the mass enthalpic quality and the ratio between liquid and vapor densities. CHF for uniformly heated smooth tubes, the maximum wall heat flue for smooth and for swirl tubes under one-side heating conditions are predicted with a reasonable accuracy by correlating these five dimensionless groups. An enhancement factor featuring the difference between one-side and uniform heating is also introduced. CHF occurrence under one-side heating is characterized by a normalized temperature, ratio between the maximal wall temperature and the onset of nucleate boiling temperature, which only depends on the pressure. According to finite element calculations performed for smooth and swirl tubes, temperature and heat flux are distributed along the inner wall of the cooling channel under one-side heating conditions. These distributions are characterized by two dimensionless numbers for each geometry: a peaking factor, which is the ratio between the maximal heat flux at the inner wall of the cooling channel and the incident heat flux, and a full width angle at half maximum of wall heat flux at the inner wall of the cooling channel. This study draws the dimensionless groups featuring CHF phenomenon not only under uniform heating, but also under one-side heating, which involve additional normalized parameters. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:147 / 171
页数:25
相关论文
共 50 条
  • [1] Dimensional analysis of critical heat flux in subcooled water flow under one-side heating conditions for fusion application
    Japan Atom. Ener. Research Institute, Naka-Fusion Research Establishment, 801-1 Naka-machi, Naka-gun, Ibaraki-ken 311-01, Japan
    不详
    不详
    Fusion Eng Des, 2 (147-171):
  • [2] Critical heat flux of water subcooled flow in one-side heated swirl tubes
    Boscary, J
    Fabre, J
    Schlosser, J
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (02) : 287 - 301
  • [3] Experimental study of subcooled flow boiling heat transfer of water in a circular channel under one-side heating conditions
    Zhu, Ge
    Bi, Qincheng
    Yan, Jianguo
    Lv, Haicai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 119 : 484 - 495
  • [4] Critical heat flux of subcooled flow boiling in water under uniform heating conditions
    Inasaka, Fujio
    Senpaku Gijutsu Kenkyusho Hokoku/Papers of Ship Research Institute, 1993, 30 (04): : 1 - 69
  • [5] Heat Transfer Characteristics of Subcooled Water in Circular Tubes With Twist Tapes Insert Under One-side Heating Conditions
    Zhu G.
    Bi Q.
    Yan J.
    Pan H.
    2018, Chinese Society for Electrical Engineering (38): : 5142 - 5149
  • [6] Critical heat flux in subcooled water flow in a saw-toothed finned duct under one-sided heating conditions
    Ezato, K
    Suzuki, S
    Sato, K
    Taniguchi, M
    Akiba, M
    FUSION TECHNOLOGY, 2001, 39 (02): : 885 - 889
  • [7] Experimental investigation of critical heat flux under boiling in subcooled swirling flow under conditions of one-sided heating
    Varava, A. N.
    Dedov, A. V.
    Komov, A. T.
    Malakhovskii, S. A.
    HIGH TEMPERATURE, 2009, 47 (06) : 843 - 848
  • [8] Experimental investigation of critical heat flux under boiling in subcooled swirling flow under conditions of one-sided heating
    A. N. Varava
    A. V. Dedov
    A. T. Komov
    S. A. Malakhovskii
    High Temperature, 2009, 47 : 843 - 848
  • [9] Critical heat flux in subcooled water flow of one-side-heated screw tubes
    Boscary, J
    Araki, M
    Suzuki, S
    Ezato, K
    Akiba, M
    FUSION TECHNOLOGY, 1999, 35 (03): : 289 - 296
  • [10] Enhancement of subcooled flow boiling critical heat flux for water in tubes with internal twisted tapes under one-sided-heating conditions
    Inasaka, F