Air-cooled heat exchanger applied to external rotary kiln wall in forced and natural draft

被引:8
|
作者
Huchet, F. [1 ]
Piton, M. [1 ]
Del Barrio, A. [1 ]
Le Corre, O. [2 ]
Cazacliu, B. [1 ]
机构
[1] IFSTTAR, MAST Dept, GPEM Lab, Route Bouaye BP4129, F-44341 Bouguenais, France
[2] IMT Atlantique Bretagne Pays Loire, GEPEA, UMR 6144, 4 Rue A Kastler, F-44307 Nantes 3, France
关键词
Mixed convection; Open-ended cavity; Tangential inlet; ENERGY; RECOVERY; FLOW; TECHNOLOGIES; CONVECTION; INDUSTRIES; CYLINDERS; DESIGN; DRUM;
D O I
10.1016/j.enconman.2017.11.031
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present paper deals with experimental measurements performed within a heat exchanger devoted to the thermal rotating machineries. The device is based on a rotor-stator system scaled from an industrial rotary kiln. The thermal recovery system is able to capture the heat losses while the kiln wall is cooled. The inner moving wall-to-air heat exchanges measured through the insulated external shell are compared to the values established in various flow conditions similar to the present geometry. The thermal convection regimes are distinguished according to the different forces exerted on the fluid air motion: the buoyancy forces being compared to the inertial effects combining the centrifugal and the axial motions. General scaling relationships devoted to the natural, mixed and forced convection regimes are proposed in an extended range of the Richardson numbers.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 50 条
  • [21] An invariant control system of an air-cooled heat exchanger of gas
    Mochalin D.S.
    Titov V.G.
    Russ Electr Eng, 8 (459-463): : 459 - 463
  • [22] PROGRAM PREDICTS AIR-COOLED HEAT-EXCHANGER PERFORMANCE
    MILLER, S
    POWER ENGINEERING, 1990, 94 (12) : 22 - 23
  • [23] Numerical investigation of fan performance in a forced draft air-cooled steam condenser
    Bredell, JR
    Kröger, DG
    Thiart, GD
    APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) : 846 - 852
  • [24] Plume recirculation in mechanical-draft air-cooled heat exchangers
    Duvenhage, K
    Kroger, DG
    HEAT TRANSFER ENGINEERING, 1995, 16 (04) : 42 - 49
  • [25] Air side heat transfer characteristics of wavy-finned-tube in a forced draft direct air-cooled steam condenser
    Zhang, Zhaoying
    Yang, Jianguo
    Zhang, Haizhen
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 3 - 8
  • [26] Thermal-economic optimization of an air-cooled heat exchanger unit
    Kashani, Amir Hesam Alinia
    Maddahi, Alireza
    Hajabdollahi, Hassan
    APPLIED THERMAL ENGINEERING, 2013, 54 (01) : 43 - 55
  • [27] The Effectiveness-NTU Approach for Evaluation of an Air-Cooled Heat Exchanger
    Asvapoositkul, Wanchai
    Kuansathan, Mantheerapol
    HEAT TRANSFER ENGINEERING, 2016, 37 (02) : 140 - 149
  • [28] Design and numerical parametric study of a compact air-cooled heat exchanger
    Huang, Zhiwei
    Ling, Jiazhen
    Hwang, Yunho
    Aute, Vikrant
    Radermacher, Reinhard
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (06) : 970 - 982
  • [29] Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger
    M. A. Habib
    S. A. Said
    A. Khalifa
    M. A. Nemitallah
    T. Ayinde
    Arabian Journal for Science and Engineering, 2014, 39 : 8187 - 8198
  • [30] Thermal Conductivity of External Contaminants of Air-Cooled Heat Exchangers
    Kuntysh V.B.
    Dudarev V.V.
    Filatov S.O.
    Korol’kova A.M.
    Chemical and Petroleum Engineering, 2017, 53 (3-4) : 244 - 247