Hemodynamic factors at the distal end-to-side anastomosis of a bypass graft with different POS:DOS flow ratios

被引:19
|
作者
Li, XM [1 ]
Rittgers, SE [1 ]
机构
[1] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
关键词
in vitro model; distal end-to-side anastomosis; flow patterns; wall shear stress; intimal hyperplasia;
D O I
10.1115/1.1372323
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A pulsatile flow in vitro model of the distal end-to-side anastomosis of an arterial bypass graft was used to examine the effects that different flow ratios between the proximal outlet segment (POS) and the distal outlet segment (DOS) have on the flow patterns and the distributions of hemodynamic factors in the anastomosis. Amberlite particles were tracked by flow visualization to determine overall flow patterns and velocity measurements were made with Laser Doppler anemometry (LDA) to obtain detailed hemodynamic factors along the artery floor and the graft hood regions. These factors included wall shear stress (WSS), spatial wall shear stress gradient (WSSG), and oscillatory index (OSI). Statistical analysis was used to compare these hemodynamic factors between cases having different POS:DOS flow ratios (Case 1-0:100, Case 2-25:75, Case 3-50:50). The results showed that changes in POS:DOS flow ratios had a great influence on the flow patterns in the anastomosis. With an increase in proximal outlet flow, the range of location of the stagnation point along the artery floor decreased, while the extent of flow separation along the graft hood increased. The statistical results showed that there were significant differences (p<0.05) for the mean WSS between cases along the graft hood, but no significant differences were detected along the artery floor. There were no significant differences for the spatial WSSG along both the artery floor and the graft hood. However, there were significant differences (p<0.05) in the mean OSI between Cases 1 and 2 and between Cases 1 and 3 both along the artery floor and along the graft hood. Comparing these mechanical factors with histological findings of intimal hyperplasia formation obtained by previous canine studies, the results of the statistical analysis suggest that regions exposed to a combination of low mean WSS and high OSI may be most prone to the formation of intimal hyperplasia.
引用
收藏
页码:270 / 276
页数:7
相关论文
共 50 条
  • [21] Advantageous swirling flow in 45° end-to-side anastomosis
    Ha, Hojin
    Choi, Woorak
    Park, Hanwook
    Lee, Sang Joon
    EXPERIMENTS IN FLUIDS, 2014, 55 (12) : 1 - 13
  • [22] The main trunk of RCA may be the best choice of sequential vein graft distal end-to-side anastomosis
    Li, Bo
    Li, Haiming
    Wang, Liangshan
    Liu, Changcheng
    Dai, Longsheng
    Li, Qin
    Gu, Chengxiong
    PERFUSION-UK, 2022, 37 (03): : 266 - 275
  • [23] Particle-hemodynamics modeling of the distal end-to-side femoral bypass: effects of graft caliber and graft-end cut
    Longest, PW
    Kleinstreuer, C
    MEDICAL ENGINEERING & PHYSICS, 2003, 25 (10) : 843 - 858
  • [24] The influence of out-of-plane geometry on pulsatile flow within a distal end-to-side anastomosis
    Papaharilaou, Y
    Doorly, DJ
    Sherwin, SJ
    JOURNAL OF BIOMECHANICS, 2002, 35 (09) : 1225 - 1239
  • [25] Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts
    Frauenfelder, Thomas
    Boutsianis, Evangelos
    Schertler, Thomas
    Husmann, Lars
    Leschka, Sebastian
    Poulikakos, Dimos
    Marincek, Borut
    BIOMEDICAL ENGINEERING ONLINE, 2007, 6 (1)
  • [26] EVALUATION OF END-TO-SIDE V END-TO-END PROXIMAL ANASTOMOSIS IN AORTOBIFEMORAL BYPASS
    PIERCE, GE
    TURRENTINE, M
    STRINGFIELD, S
    ILIOPOULOS, J
    HARDIN, CA
    HERMRECK, AS
    THOMAS, JH
    ARCHIVES OF SURGERY, 1982, 117 (12) : 1580 - 1588
  • [27] Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts
    Thomas Frauenfelder
    Evangelos Boutsianis
    Thomas Schertler
    Lars Husmann
    Sebastian Leschka
    Dimos Poulikakos
    Borut Marincek
    Hatem Alkadhi
    BioMedical Engineering OnLine, 6
  • [28] DOPPLER COLOR-FLOW IMAGES OF ILIOFEMORAL GRAFT END-TO-SIDE DISTAL ANASTOMOTIC MODELS
    RITTGERS, SE
    BHAMBHANI, GH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (04): : 257 - 267
  • [29] Hemodynamic analysis of pulsatile blood flow in a complete bypass graft with different anastomosis angles
    Zohravi, E.
    Shirani, E.
    Sadeghi, M. R.
    SCIENTIA IRANICA, 2015, 22 (02) : 423 - 435
  • [30] That the end-to-end anastomosis is superior to the end-to-side anastomosis for peripheral bypass surgery: Observations from computational studies
    O'Brien, T.
    Walsh, M.
    Grace, P.
    Devereux, P.
    O'Callaghan, S.
    Burke, P.
    McGloughlin, T.
    PROCEEDINGS OF THE 5TH WORLD CONGRESS OF BIOMECHANICS, 2006, : 579 - +