Hemodynamic factors at the distal end-to-side anastomosis of a bypass graft with different POS:DOS flow ratios

被引:19
|
作者
Li, XM [1 ]
Rittgers, SE [1 ]
机构
[1] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
关键词
in vitro model; distal end-to-side anastomosis; flow patterns; wall shear stress; intimal hyperplasia;
D O I
10.1115/1.1372323
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A pulsatile flow in vitro model of the distal end-to-side anastomosis of an arterial bypass graft was used to examine the effects that different flow ratios between the proximal outlet segment (POS) and the distal outlet segment (DOS) have on the flow patterns and the distributions of hemodynamic factors in the anastomosis. Amberlite particles were tracked by flow visualization to determine overall flow patterns and velocity measurements were made with Laser Doppler anemometry (LDA) to obtain detailed hemodynamic factors along the artery floor and the graft hood regions. These factors included wall shear stress (WSS), spatial wall shear stress gradient (WSSG), and oscillatory index (OSI). Statistical analysis was used to compare these hemodynamic factors between cases having different POS:DOS flow ratios (Case 1-0:100, Case 2-25:75, Case 3-50:50). The results showed that changes in POS:DOS flow ratios had a great influence on the flow patterns in the anastomosis. With an increase in proximal outlet flow, the range of location of the stagnation point along the artery floor decreased, while the extent of flow separation along the graft hood increased. The statistical results showed that there were significant differences (p<0.05) for the mean WSS between cases along the graft hood, but no significant differences were detected along the artery floor. There were no significant differences for the spatial WSSG along both the artery floor and the graft hood. However, there were significant differences (p<0.05) in the mean OSI between Cases 1 and 2 and between Cases 1 and 3 both along the artery floor and along the graft hood. Comparing these mechanical factors with histological findings of intimal hyperplasia formation obtained by previous canine studies, the results of the statistical analysis suggest that regions exposed to a combination of low mean WSS and high OSI may be most prone to the formation of intimal hyperplasia.
引用
收藏
页码:270 / 276
页数:7
相关论文
共 50 条
  • [1] Distal Placement of an End-to-Side Bypass Graft Anastomosis: A 3D Computational Study
    Di Cicco, John
    Demuren, Ayodeji
    JOURNAL OF ENGINEERING, 2013, 2013
  • [2] Distal placement of an end-to-side bypass graft anastomosis: A 3-D computational study
    Di Cicco, John R.
    Demuren, Ayodeji O.
    Proceedings of the ASME Fluids Engineering Division Summer Conference - 2005, Vol 1, Pts A and B, 2005, : 289 - 296
  • [3] Why Patencies of Femoropopliteal Bypass Grafts with Distal End-to-End Anastomosis are Comparable with End-to-Side Anastomosis
    Hoedt, Marco
    How, Thien
    Poyck, Paul
    Wittens, Cees
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 21 (02) : 157 - 164
  • [4] Unsteady simulation of distal blood flow in an end-to-side anastomosed coronary bypass graft with stenosis
    Najarian, Siamak
    Dargahi, Javad
    Firouzi, Faramarz
    Afsari, Jamshid
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2006, 16 (05) : 337 - 347
  • [5] Numerical modelling of Newtonian and non-Newtonian representation of blood in a distal end-to-side vascular bypass graft anastomosis
    O'Callaghan, S
    Walsh, M
    McGloughlin, T
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (01) : 70 - 74
  • [6] Effects of geometry and flow division on flow structures in models of the distal end-to-side anastomosis
    Hughes, PE
    How, TV
    JOURNAL OF BIOMECHANICS, 1996, 29 (07) : 855 - 872
  • [7] The Ratio of Diameters Between the Target Artery and the Bypass Modifies Hemodynamic Parameters Related to Intimal Hyperplasia in the Distal End-to-Side Anastomosis
    Grus, T.
    Lambert, L.
    Matecha, J.
    Grusova, G.
    Spacek, M.
    Mlcek, M.
    PHYSIOLOGICAL RESEARCH, 2016, 65 (06) : 901 - 908
  • [8] PROXIMAL ANASTOMOSIS IN AORTOBIFEMORAL BYPASS - END-TO-END OR END-TO-SIDE
    MELLIERE, D
    LABASTIE, J
    BECQUEMIN, JP
    KASSAB, M
    PARIS, E
    JOURNAL OF CARDIOVASCULAR SURGERY, 1990, 31 (01): : 77 - 80
  • [9] FLOW DISTURBANCE AT THE DISTAL END-TO-SIDE ANASTOMOSIS - EFFECT OF PATENCY OF THE PROXIMAL OUTFLOW SEGMENT AND ANGLE OF ANASTOMOSIS
    CRAWSHAW, HM
    QUIST, WC
    SERRALLACH, E
    VALERI, CR
    LOGERFO, FW
    ARCHIVES OF SURGERY, 1980, 115 (11) : 1280 - 1284
  • [10] Correlation between blood flow patterns and intimal hyperplasia at the distal end-to-side anastomosis
    Xu, ZP
    Deng, XY
    Fan, YB
    Liu, LJ
    Bi, YP
    Yang, QH
    Proceedings of the Third IASTED International Conference on BIOMECHANICS, 2005, : 77 - 80