Simple and rapid determination of trace bromate by flow injection analysis with novel spec trophotometric detection system

被引:3
|
作者
Isawa, Miki [1 ]
Yamane, Takeshi [1 ]
机构
[1] Yamanashi Univ, Fac Educ & Human Sci, Dept Sci Educ, Kofu, Yamanashi 4008510, Japan
关键词
trace bromate; V(V)-nitro-PAPS complex; spectrophotometric detection; FI system; drinking water;
D O I
10.2116/bunsekikagaku.56.745
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection system with a novel detection reaction is presented for determining trace bromate in drinking water. Bromate is used to oxidize V(IV) to V(V), and then Nitro-PAPS 12-(5Nitro-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino] phenol) reacts with V(V) to form a complex that is monitored spectrophotometricaly at 592 nm in a continuous flow system. The variables related to such reactions were studied in detail, and the optimal conditions and manifold configurations were established. A linear calibration using a 2 m sample loop injection was obtained for bromate in the range of 0 similar to 0.05 ppm. The coefficient of variation for 0.01 ppm bromate (n = 3) was 0.6%, and the estimated limit of detection (3 sigma) was 0.0004 ppm. Only 4 min was required for an analytical measurement after sample injection. The present FI system was successfully in-line coupled with anion-exchange separation using 0.05 M NaCl as an eluent for a more sensitive and selective determination of trace bromate. In this case, using a 3 m sample loop, the limit of detection (3 a) was 0.0002 ppm bromate, the rsd for 0.01 ppm bromate was 1.4% and the time required for an analytical measurement was 9 min. Tap water samples supplied from 3 cities and a bottled water were analysed by this FI system; satisfactory recoveries of 96 similar to 104% were found for spiked bromate.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 50 条
  • [31] Simple and rapid pyrolysis condition for determination of fluoride ion in cements by spectrophotometric flow injection analysis
    Noguchi, Yasunari
    Maruta, Toshihisa
    Kiba, Nobutoshi
    Yamane, Takeshi
    [J]. BUNSEKI KAGAKU, 2007, 56 (11) : 939 - 943
  • [32] A sensitive procedure for the rapid determination of arsenic(III) by flow injection analysis and chemiluminescence detection
    Satienperakul, S
    Cardwell, TJ
    Kolev, SD
    Lenehan, CE
    Barnett, NW
    [J]. ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) : 25 - 30
  • [33] A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection
    Alam, Seikh Mafiz
    Jeon, Chi Wan
    Karim, Mohammad Mainul
    Lee, Sang Hak
    Wabaidur, Saikh Mohammad
    Suh, Yeoun Suk
    Chung, Hye Young
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (01): : 102 - 106
  • [34] Simple and clean determination of tetracyclines by flow injection analysis
    Rodriguez, Michael Perez
    Pezza, Helena Redigolo
    Pezza, Leonardo
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 153 : 386 - 392
  • [35] A simple and rapid batch injection analysis method with amperometric detection for determination of azithromycin in pharmaceutical tablets
    Castro, Lizandra N.
    Lopes, Carlos E. C.
    Santos-Neto, Domingos R.
    Silva, Luiz Ricardo G.
    Tanaka, Auro A.
    Dantas, Luiza M. F.
    da Silva, Iranaldo S.
    [J]. IONICS, 2024, : 7575 - 7584
  • [36] FTIR microscopy as novel detection system in micro flow injection analysis
    Technical Univ of Vienna, Vienna, Austria
    [J]. Anal Methods Instrum, 1 (52-54):
  • [37] Rapid determination of biomass activity by flow injection analysis
    Ding, T.
    Bilitewski, U.
    Schmid, R.D.
    [J]. Proceedings of the International Seminar on Biosensors - Fundamentals, Technologies and Applications, 1992,
  • [38] Flow-injection determination of trace amounts of dopamine by chemiluminescence detection
    Zhang, LH
    Teshima, N
    Hasebe, T
    Kurihara, M
    Kawashima, T
    [J]. TALANTA, 1999, 50 (03) : 677 - 683
  • [39] FLOW-INJECTION DETERMINATION OF TRACE VANADIUM WITH CATALYTIC PHOTOMETRIC DETECTION
    YAMANE, T
    FUKASAWA, T
    [J]. ANALYTICA CHIMICA ACTA, 1980, 119 (02) : 389 - 392
  • [40] DETERMINATION OF TRACE AMOUNTS OF COBALT BY FLOW-INJECTION WITH SPECTROPHOTOMETRIC DETECTION
    PYRZYNSKA, K
    JANISZEWSKA, Z
    SZPUNARLOBINSKA, J
    TROJANOWICZ, M
    [J]. ANALYST, 1994, 119 (07) : 1553 - 1556