Low flow, long-term air sampling under normal domestic activity to measure house dust mite and cockroach allergens

被引:0
|
作者
Park, JW [1 ]
Kim, CW [1 ]
Kang, DB [1 ]
Lee, IY [1 ]
Choi, SY [1 ]
Yong, TS [1 ]
Shin, DC [1 ]
Kim, KE [1 ]
Hong, CS [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Internal Med, Inst Allergy, Seoul, South Korea
关键词
house dust mite; cockroach; air sampler; indoor allergens;
D O I
暂无
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Successful applications of air sampling for the quantification of exposure to indoor allergens have been reported, but its efficiency is still controversial. We evaluated whether the low-flow long-term air sampling in normal domestic activity conditions can quantify the exposure of house dust mites (HDM) and cockroaches (CR) allergens or not. Airborne Der f 1 and Bla g 1 were captured with a personal air sampler in 25 bedrooms during normal domestic activity. Quantification of the major allergens in the reservoir dust and the extraction of the air sampler filters were done with two-site ELISA kits. Airborne Der f 1 was measured above the threshold level of detection in 15 houses (60%). Detection rate of airborne Der f 1 was significantly higher in those houses where D farinae was microscopically found in the reservoir dusts (76.5% vs. 25% chi(2) = 6.0, p = 0.014). Airborne Der f 1 was more <LF>frequently detected in the houses with higher Der f 1 (greater than or equal to 10 mug/g dust) in bedding reservoir dust than the other group (91% vs. 35.7% chi(2) = 7.819, p = 0.005), and the median <LF>value of airborne Der f 1 was also significantly higher in that group (14.0 pg/m(3) vs. below detection limit, p = 0.002). <LF>Airborne Der f 1 was significantly correlated with Der f 1 in bedding reservoir dust (r = 0.591, p < 0.01). Airborne Bla g 1 was measured with ELISA in 16 houses (64%) and it was more frequently detected in the houses where the CRs were captured by adhesive traps (91% vs. 57% χ(2) = 3.484, p = <LF>0.06). The median concentration of Bla g 1 in the filter was also higher in the houses with captured CRs (0.12 vs. 0.05 mU/m(3), p = 0.06), but the level of Bla g 1 did not correlate with that of the bedding dusts or the floor dusts of kitchen. These results suggested that airborne HDM or CR allergens could be measured by low-flow, long-term air sampling, and that it might be one of appropriate modalities for evaluating personal exposure to HDM and CR allergens.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [41] Flow cytometry of murine bone marrow: long-term repopulating activity should be attributed to lineage low, not to lineage negative subset
    Savvulidi, F.
    Sefc, L.
    Necas, E.
    BONE MARROW TRANSPLANTATION, 2011, 46 : S306 - S307
  • [42] Long-term risk stratification with low-dose dobutamine testing in asymptomatic low-flow patients with severe aortic stenosis and normal ejection fraction
    Banovic, M.
    Brkovic, V.
    Vujisic-Tesic, B.
    Jaukovic, M.
    Nedeljkovic, I.
    Popovic, D.
    Trifunovic, D.
    Ristic, A.
    EUROPEAN HEART JOURNAL, 2016, 37 : 557 - 557
  • [43] Long-term risk stratification with low-dose dobutamine testing in asymptomatic low-flow patients with severe aortic stenosis and normal ejection fraction
    Marko, Banovic
    Voin, Brkovic
    Bosiljka, Vujisic-Tesic
    Ivana, Nedeljkovic
    Danijela, Trifunovic
    Ana, Mladenovic
    Dejana, Popovic
    Serjan, Nikolic
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (03) : 1275 - 1277
  • [44] HfB2-SiC (45 vol %) ceramic material: Manufacture and behavior under long-term exposure to dissociated air jet flow
    Sevastyanov, V. G.
    Simonenko, E. P.
    Gordeev, A. N.
    Simonenko, N. P.
    Kolesnikov, A. F.
    Papynov, E. K.
    Shichalin, O. O.
    Avramenko, V. A.
    Kuznetsov, N. T.
    RUSSIAN JOURNAL OF INORGANIC CHEMISTRY, 2014, 59 (11) : 1298 - 1311
  • [45] HfB2-SiC (45 vol %) ceramic material: Manufacture and behavior under long-term exposure to dissociated air jet flow
    V. G. Sevastyanov
    E. P. Simonenko
    A. N. Gordeev
    N. P. Simonenko
    A. F. Kolesnikov
    E. K. Papynov
    O. O. Shichalin
    V. A. Avramenko
    N. T. Kuznetsov
    Russian Journal of Inorganic Chemistry, 2014, 59 : 1298 - 1311
  • [46] Long-term mortality in patients with paradoxical low-flow low-gradient versus normal-flow high-gradient aortic stenosis undergoing transcatheter aortic valve implantation
    Fusini, L.
    Muratori, M.
    Tamborini, G.
    Ali, S. Ghulam
    Gripari, P.
    Salvi, L.
    Roberto, M.
    Trabattoni, P.
    Agrifoglio, M.
    Bartorelli, A. L.
    Alamanni, F.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2019, 40 : 524 - 524
  • [47] Ablation Mechanism and Process of Low-Density Needled Quartz Felt/Phenolic Resin Thermal Protection Materials Under Long-Term Low-Medium Heat Flow
    Huang, Xiaoyu
    Zhao, Yuwen
    Wang, Kaining
    Wang, Yifan
    Ding, Chen
    Wang, Yichun
    Liu, Xianlong
    Duan, Xiuhui
    AEROSPACE, 2025, 12 (02)
  • [48] CHRONIC GROWTH-RETARDATION WITH NORMAL GROWTH-HORMONE RESPONSE TO PROVOCATIVE STIMULI AND LOW SOMATOMEDIN ACTIVITY - LONG-TERM THERAPY WITH HUMAN GROWTH-HORMONE
    CARRASCOSA, A
    VICENSCALVET, E
    AUDI, L
    GUSINYE, M
    ALBISU, M
    POTAU, N
    ACTA PAEDIATRICA SCANDINAVICA, 1987, 76 (03): : 489 - 494
  • [49] Early Improvement in Disease Activity Indices Predicts Achievement of Long-term Clinical Remissions, ASDAS Inactive Disease and Low BASDAI with Normal CRP, During TNF-α-inhibitor Therapy in Patients with Ankylosing Spondylitis
    Lee, Sang Jin
    Kim, Na Ri
    Nam, Eon
    ARTHRITIS & RHEUMATOLOGY, 2021, 73 : 1942 - 1944
  • [50] LONG-TERM HIGH-VOLUME AND LOW-VOLUME AIR SAMPLING OF POLYCHLORINATED DIBENZO-PARA-DIOXINS AND DIBENZOFURANS AND POLYCYCLIC AROMATIC-HYDROCARBONS ALONG A TRANSECT FROM URBAN TO REMOTE AREAS ON THE SWEDISH BALTIC COAST
    BROMAN, D
    NAF, C
    ZEBUHR, Y
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (11) : 1841 - 1850