The Effect of Intrinsic Radiation from a 3 x 3-in. LaBr3(Ce) Scintillation Detector on In Situ Artificial Radiation Measurements

被引:1
|
作者
Li Sangang [1 ,4 ]
Cheng Yi [1 ]
Wang Lei [1 ,2 ]
Yang Li [3 ,4 ]
Liu Huan [1 ]
Liao Jiawei [1 ]
Zeng Liyang [1 ]
Luo Yong [1 ]
Wang Xiaoyu [4 ]
Pei Qiuyan [4 ]
Wang Jie [4 ]
机构
[1] Chengdu Univ Technol, Chengdu 610059, Sichuan, Peoples R China
[2] State Key Lab Geohazard Prevent & Geoenvironm Pro, Chengdu 610059, Sichuan, Peoples R China
[3] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[4] Univ Sci & Technol China, Hefei 230027, Anhui, Peoples R China
关键词
Intrinsic radiation; LaBr3(Ce) detector; in situ radiation measurement; minimum detectable activity; CONTAMINATION; CS-137;
D O I
10.1080/00295450.2018.1474704
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In situ radiation measurements are commonly used to detect radioactive material in luggage; at border control checkpoints; for in-field monitoring; during the illicit transfer of nuclear material; and at radioactive contamination sites, e.g., the Fukushima nuclear accident site. In considering the high brightness, fast decay time, and good energy resolution of cerium-doped lanthanum bromide [LaBr3(Ce)] scintillation detectors, this work conducted an experimental analysis aimed at evaluating the potential for applying LaBr3(Ce) detectors to in situ artificial radiation measurements. The effect of the intrinsic radiation of the LaBr3(Ce) detector was investigated. In addition, the intrinsic radiation contribution to the background radiation of the region of interest (ROI) under full-energy peaks for several artificial point sources and the minimum detectable activity (MDA) values of a 3 x 3-in. LaBr3(Ce) detector for several artificial radioactive point sources under unshielded (in the natural background) and well-shielded (in a low background chamber) conditions were calculated. The results indicate that the intrinsic radiation has a significant effect on the background radiation of the ROI especially when the full-energy peaks of several artificial point sources are located in the low-energy region or near 789 and 1400 keV. In addition, the MDAs (the measured time is 300 s) of the LaBr3(Ce) detector for Eu-152 (121.78 keV), Ba-133 (356 keV), Cs-137 (661.7 keV), and Co-60 (1332.5 keV) were 218.2, 63.6, 61.3, and 59.6 Bq, respectively, under unshielded conditions and 111.4, 39.1, 46.1, and 38.6 Bq, respectively, under well-shielded conditions. The intrinsic radiation also has some effects on the MDA of the LaBr3(Ce) detector, especially in the low-energy region. Thus, the drawback of its intrinsic radiation limits its application to in situ weak artificial radiation measurements, but LaBr3(Ce) detectors have the potential for use in medium-and high-radiation measurements due to the better energy resolution of these detectors than NaI(Tl) detectors.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 50 条
  • [31] X-ray and gamma-ray response of a 2" x 2" LaBr3:Ce scintillation detector
    Quarati, F.
    Bos, A. J. J.
    Brandenburg, S.
    Dathy, C.
    Dorenbos, P.
    Kraft, S.
    Ostendorf, R. W.
    Ouspenski, V.
    Owens, Alan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (01): : 115 - 120
  • [32] LaBr3:Ce scintillation gamma camera prototype for X and gamma ray imaging
    Pani, R.
    Cinti, M. N.
    Pellegrini, R.
    Bennati, P.
    Betti, M.
    Vittorini, F.
    Mattioli, M.
    Trotta, G.
    Cencelli, V. Orsolini
    Scafe, R.
    Navarria, F.
    Bollini, D.
    Baldazzi, G.
    Moschini, G.
    De Notaristefani, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 15 - 18
  • [33] Calibration of the angular energy efficiency of an in situ spectrometer based on a LaBr3(Ce) detector
    Jednorog, Slawomir
    Ciupek, Krzysztof
    Krajewski, Pawel
    Laszynska, Ewa
    Ziolkowski, Adam
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 305 (02) : 567 - 571
  • [34] Calibration of the angular energy efficiency of an in situ spectrometer based on a LaBr3(Ce) detector
    Slawomir Jednorog
    Krzysztof Ciupek
    Pawel Krajewski
    Ewa Laszynska
    Adam Ziolkowski
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 305 : 567 - 571
  • [35] Properties of a very large volume LaBr3:Ce detector
    Giaz, A.
    Pellegri, L.
    Riboldi, S.
    Camera, F.
    Blasi, N.
    Boiano, C.
    Brambilla, S.
    Ceruti, S.
    Crespi, F. C. L.
    Csatlos, M.
    Gulyas, J.
    Krasznahorkay, A.
    Lodetti, S.
    Million, B.
    Stuhl, L.
    Wieland, O.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 331 - 334
  • [36] A gated LaBr3(Ce) detector for border protection applications
    Etile, A.
    Denis-Petit, D.
    Gaudefroy, L.
    Meot, V.
    Roig, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 877 : 323 - 327
  • [37] The 2024 LaBr3(Ce) detector setup for the FAMU experiment
    Rossini, Riccardo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1069
  • [38] Assessment of the radiation tolerance of LaBr3:Ce scintillators to solar proton events
    Owens, Alan
    Bos, A. J. J.
    Brandenburg, S.
    Buis, E. -J.
    Dathy, C.
    Dorenbos, P.
    van Eijk, C. W. E.
    Kraft, S.
    Ostendorf, R. W.
    Ouspenski, V.
    Quarati, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02): : 785 - 793
  • [39] Studying the spectrometric characteristics of an ionizing-radiation detector based on a LaBr3(Ce) scintillator and a silicon photomultiplier
    Berdnikova, A. K.
    Dubinin, F. A.
    Dmitrenko, V. V.
    Zhukov, K. I.
    Kantserov, V. A.
    Klassen, N. V.
    Orlov, A. D.
    Pereima, D. Yu.
    Shmurak, S. Z.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2017, 60 (02) : 182 - 187
  • [40] Measurement of 235U enrichment with a LaBr3 scintillation detector
    Mortreau, P.
    Berndt, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3): : 324 - 331