The Effect of Intrinsic Radiation from a 3 x 3-in. LaBr3(Ce) Scintillation Detector on In Situ Artificial Radiation Measurements

被引:1
|
作者
Li Sangang [1 ,4 ]
Cheng Yi [1 ]
Wang Lei [1 ,2 ]
Yang Li [3 ,4 ]
Liu Huan [1 ]
Liao Jiawei [1 ]
Zeng Liyang [1 ]
Luo Yong [1 ]
Wang Xiaoyu [4 ]
Pei Qiuyan [4 ]
Wang Jie [4 ]
机构
[1] Chengdu Univ Technol, Chengdu 610059, Sichuan, Peoples R China
[2] State Key Lab Geohazard Prevent & Geoenvironm Pro, Chengdu 610059, Sichuan, Peoples R China
[3] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[4] Univ Sci & Technol China, Hefei 230027, Anhui, Peoples R China
关键词
Intrinsic radiation; LaBr3(Ce) detector; in situ radiation measurement; minimum detectable activity; CONTAMINATION; CS-137;
D O I
10.1080/00295450.2018.1474704
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In situ radiation measurements are commonly used to detect radioactive material in luggage; at border control checkpoints; for in-field monitoring; during the illicit transfer of nuclear material; and at radioactive contamination sites, e.g., the Fukushima nuclear accident site. In considering the high brightness, fast decay time, and good energy resolution of cerium-doped lanthanum bromide [LaBr3(Ce)] scintillation detectors, this work conducted an experimental analysis aimed at evaluating the potential for applying LaBr3(Ce) detectors to in situ artificial radiation measurements. The effect of the intrinsic radiation of the LaBr3(Ce) detector was investigated. In addition, the intrinsic radiation contribution to the background radiation of the region of interest (ROI) under full-energy peaks for several artificial point sources and the minimum detectable activity (MDA) values of a 3 x 3-in. LaBr3(Ce) detector for several artificial radioactive point sources under unshielded (in the natural background) and well-shielded (in a low background chamber) conditions were calculated. The results indicate that the intrinsic radiation has a significant effect on the background radiation of the ROI especially when the full-energy peaks of several artificial point sources are located in the low-energy region or near 789 and 1400 keV. In addition, the MDAs (the measured time is 300 s) of the LaBr3(Ce) detector for Eu-152 (121.78 keV), Ba-133 (356 keV), Cs-137 (661.7 keV), and Co-60 (1332.5 keV) were 218.2, 63.6, 61.3, and 59.6 Bq, respectively, under unshielded conditions and 111.4, 39.1, 46.1, and 38.6 Bq, respectively, under well-shielded conditions. The intrinsic radiation also has some effects on the MDA of the LaBr3(Ce) detector, especially in the low-energy region. Thus, the drawback of its intrinsic radiation limits its application to in situ weak artificial radiation measurements, but LaBr3(Ce) detectors have the potential for use in medium-and high-radiation measurements due to the better energy resolution of these detectors than NaI(Tl) detectors.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 50 条
  • [1] Application of a LaBr3(Ce) Scintillation Detector to an Environmental Radiation Monitor
    Ji, Young-Yong
    Choi, Hee-Yeoul
    Lee, Wanno
    Kim, Chang-Jong
    Chang, Hyun-Sock
    Chung, Kun-Ho
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (08) : 2021 - 2028
  • [2] Intrinsic background radiation of LaBr3(Ce) detector via coincidence measurements and simulations
    Cheng, Hao
    Sun, Bao-Hua
    Zhu, Li-Hua
    Li, Tian-Xiao
    Li, Guang-Shuai
    Li, Cong-Bo
    Wu, Xiao-Guang
    Zheng, Yun
    NUCLEAR SCIENCE AND TECHNIQUES, 2020, 31 (10)
  • [3] Intrinsic background radiation of LaBr3(Ce) detector via coincidence measurements and simulations
    Hao Cheng
    Bao-Hua Sun
    Li-Hua Zhu
    Tian-Xiao Li
    Guang-Shuai Li
    Cong-Bo Li
    Xiao-Guang Wu
    Yun Zheng
    Nuclear Science and Techniques, 2020, 31
  • [4] Intrinsic background radiation of LaBr3(Ce) detector via coincidence measurements and simulations
    Hao Cheng
    Bao-Hua Sun
    Li-Hua Zhu
    Tian-Xiao Li
    Guang-Shuai Li
    Cong-Bo Li
    Xiao-Guang Wu
    Yun Zheng
    Nuclear Science and Techniques, 2020, 31 (10) : 35 - 44
  • [5] RADIATION BACKGROUND IN A LABR3(CE) GAMMA-RAY SCINTILLATION DETECTOR
    Rosson, Robert
    Lahr, Jeffrey
    Kahn, Bernd
    HEALTH PHYSICS, 2011, 101 (06): : 703 - 708
  • [6] Properties and Application Studies of LaBr3 (Ce) Scintillation Detector
    Zhang Hai-wei
    Wang Lei
    Leng Feng-qing
    Tuo Xian-guo
    Liu Ming-zhe
    Cheng Yi
    Yao Fu-liang
    Li San-gang
    Zhao Bai-jun
    Lu Wei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (07) : 2298 - 2304
  • [7] LaBr3:: Ce scintillation camera
    Pani, R.
    Cinti, M. N.
    Pellegrini, R.
    De Notaristefani, F.
    Bennati, P.
    Betti, M.
    Trotta, G.
    Mattioli, M.
    Garibaldi, F.
    Orsolini Cencelli, V
    Moschini, G.
    Navarria, F.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2061 - 2065
  • [8] Comparison of a LaBr3(Ce) scintillation detector with a large volume CdZnTe detector
    Syntfeld, Agnieszka
    Arlt, Rolf
    Gostilo, Vladimir
    Loupilov, Alexander
    Moszynski, Marek
    Nassalski, Antoni
    Swoboda, Martha
    Wolski, Dariusz
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (06) : 3938 - 3943
  • [9] Response of LaBr3:Ce scintillation detector itself to fast neutrons
    Liu, C.
    Ma, H.
    Pan, X.
    Zeng, Z.
    Li, J.
    Zhang, H.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [10] 3"x 3" LaBr3:Ce detector response to monochromatic protons
    Giaz, A.
    Brambilla, S.
    Szpak, B.
    Zieblinski, M.
    Blasi, N.
    Boiano, C.
    Camera, F.
    Ceruti, S.
    Million, B.
    Riboldi, S.
    Wieland, O.
    Bednarczyk, P.
    Ciemala, M.
    Fornal, B.
    Jastrzab, M.
    Kmiecik, M.
    Krzysiek, M.
    Maj, A.
    Meczynski, W.
    Napiorkowski, P.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,