Clinical recurrence and electrical pulmonary vein reconnections after second-generation cryoballoon ablation

被引:37
|
作者
Miyazaki, Shinsuke [1 ]
Taniguchi, Hiroshi [1 ]
Hachiya, Hitoshi [1 ]
Nakamura, Hiroaki [1 ]
Takagi, Takamitsu [1 ]
Hirao, Kenzo [2 ]
Iesaka, Yoshito [1 ]
机构
[1] Tsuchiura Kyodo Gen Hosp, Cardiovasc Ctr, Tsuchiura, Ibaraki, Japan
[2] Tokyo Med & Dent Univ, Heart Rhythm Ctr, Tokyo, Japan
关键词
Pulmonary vein reconnection; Cryoballoon; Pulmonary vein isolation; Durability; PAROXYSMAL ATRIAL-FIBRILLATION; PHRENIC-NERVE INJURY; CATHETER ABLATION; RADIOFREQUENCY ABLATION; EFFICACY; SAFETY; VALIDATION; CONDUCTION; IMPACT; TIME;
D O I
10.1016/j.hrthm.2016.05.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Electrical reconnections after pulmonary vein isolation (PVI) are less common after second -generation cryoballoon than radiofrequency ablation. OBJECTIVE The purpose of this study was to investigate the incidence and characteristics of pulmonary vein (PV) reconnections after second -generation cryoballoon ablation in patients with and those without clinical recurrences. METHODS Forty patients with paroxysmal atrial fibrillation undergoing second procedures after cryoballoon ablation were enrolled. Twenty-five patients experienced clinical recurrences, and the remaining 15 did not. RESULTS All 158 PVs were reevaluated a median [25th, 75th percentiles] of 6.0 [4.0-9.0] months after the initial procedure. In total, reconnections were detected in 39 PVs (24.7%) among 25 patients (62.5%). Reconnected PVs included 6 left superior (LS) (15.8%), 7 left inferior (LI) (18.4%), 5 right superior (RS) (12.5%), 20 right inferior (RI) (50.0%), and 1 left common (LC) (50.0%) PV. Reconnected PV potential conduction delays were a median of 112 [76-130], 103 [82-133], 84 [66-96], 68 [49-73], and 204 ms in the LS, LI, RS, RI, and LC PV, respectively. There was no significant difference between those with and those without clinical recurrences with regard to clinical characteristics, procedural results, incidence of reconnections (25/98 vs 14/60, P = .758), and PV conduction delays in each PV. The most common gap location was the RI PV bottom in both groups. Among 5 patients with reconnections of arrhythmogenic PVs (with atrial fibrillation initiation), 2 experienced clinical recurrences, whereas 3 did not. Non-PV foci (with atrial fibrillation initiation) were identified in a second procedures in 10 of 25 patients with clinical recurrences. CONCLUSION The incidence and characteristics of PV reconnections after second-generation cryoballoon ablation were similar between patients with and those without clinical recurrences. The results should be considered when discussing the optimal dose of cryoballoon applications. (C) 2016 Heart Rhythm Society. All rights reserved.
引用
收藏
页码:1852 / 1857
页数:6
相关论文
共 50 条
  • [11] Incidence of early pulmonary vein reconnections using different energy sources for pulmonary vein isolation: Multielectrode phased radiofrequency vs second-generation cryoballoon
    Wieczorek, Marcus
    Tajtaraghi, Sharam
    Sassani, Kiarash
    Hoeltgen, Reinhard
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1428 - 1435
  • [12] Atrioventricular conduction disturbance during pulmonary vein isolation using the second-generation cryoballoon - Vagal impact of cryoballoon ablation
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Watanabe, Tomonori
    Hada, Masahiro
    Yamao, Kazuya
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Tada, Hiroshi
    Hirao, Kenzo
    Iesaka, Yoshito
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 265 : 113 - 117
  • [13] Early Recurrence After Pulmonary Vein Isolation of Paroxysmal Atrial Fibrillation With Different Ablation Technologies - Prospective Comparison of Radiofrequency vs. Second-Generation Cryoballoon Ablation
    Miyazaki, Shinsuke
    Kuroi, Akio
    Hachiya, Hitoshi
    Nakamura, Hiroaki
    Taniguchi, Hiroshi
    Ichihara, Noboru
    Takagi, Takamitsu
    Iwasawa, Jin
    Iesaka, Yoshito
    CIRCULATION JOURNAL, 2016, 80 (02) : 346 - +
  • [14] Outcome in patients with left common pulmonary vein after cryoablation with second-generation cryoballoon
    Beiert, Thomas
    Lodde, Pia C.
    Linneborn, Lutz P. T.
    Werner, Jessica
    Prinz, Lisa
    Stoeckigt, Florian
    Linhart, Markus
    Lickfett, Lars
    Nickenig, Georg
    Schrickel, Jan W.
    Andrie, Rene P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (01): : 22 - 27
  • [15] Impact of electrical connections between ipsilateral pulmonary veins on the second-generation cryoballoon ablation procedure
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Watanabe, Tomonori
    Hada, Masahiro
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Tada, Hiroshi
    Hirao, Kenzo
    Iesaka, Yoshito
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (01) : 27 - 31
  • [16] Autonomic nervous system modulation and clinical outcome after pulmonary vein isolation using the second-generation cryoballoon
    Miyazaki, Shinsuke
    Nakamura, Hiroaki
    Taniguchi, Hiroshi
    Hachiya, Hitoshi
    Kajiyama, Takatsugu
    Watanabe, Tomonori
    Igarashi, Miyako
    Ichijo, Sadamitsu
    Hirao, Kenzo
    Iesaka, Yoshito
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (09) : 1015 - 1020
  • [17] Improved In Vivo Performance of Second-Generation Cryoballoon for Pulmonary Vein Isolation
    Coulombe, Nicolas
    Paulin, Jaime
    Su, Wilber
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (08) : 919 - 925
  • [18] Anatomic predictors of late right inferior pulmonary vein reconnection in the setting of second-generation cryoballoon ablation
    Terasawa, Muryo
    Chierchia, Gian-Battista
    Takarada, Ken
    Rizzo, Alessandro
    Maj, Riccardo
    Borio, Gianluca
    Osorio, Thiago Guimaraes
    Scala, Oriana
    Galli, Alessio
    Al Housari, Maysam
    Tanaka, Kaoru
    Sieira, Juan
    Brugada, Pedro
    de Asmundis, Carlo
    Stroker, Erwin
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2294 - 2301
  • [19] Ablation index-guided ablation versus second-generation cryoballoon for first pulmonary vein isolation in atrial fibrillation
    Felix-Oliveira, A.
    Carmo, J.
    Carmo, P.
    Cavaco, D.
    Fontes, A.
    Rodrigues, G.
    Matos, D.
    Moscoso Costa, F.
    Bello Morgado, F.
    Adragao, P.
    Carvalho, S.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1212 - 1212
  • [20] Phrenic nerve injury during right inferior pulmonary vein ablation with the second-generation cryoballoon: clinical, procedural, and anatomical characteristics
    Abugattas, Juan-Pablo
    de Asmundis, Carlo
    Iacopino, Saverio
    Salghetti, Francesca
    Takarada, Ken
    Coutino, Hugo-Enrique
    Stroker, Erwin
    De Regibus, Valentina
    de Greef, Yves
    Brugada, Pedro
    Sieira, Juan
    Chierchia, Gian-Battista
    EUROPACE, 2018, 20 (10): : E156 - E163