Study on AC loss measurements of HTS power cable for standardizing

被引:3
|
作者
Mukoyama, Shinichi [1 ]
Amemiya, Naoyuki [2 ]
Watanabe, Kazuo [3 ]
Iijima, Yasuhiro [3 ]
Mido, Nobuhiro [4 ]
Masuda, Takao [5 ]
Morimura, Toshiya [5 ]
Oya, Masayoshi [5 ]
Nakano, Tetsutaro [6 ]
Yamamoto, Kiyoshi [7 ]
机构
[1] Furukawa Elect Corp Ltd, Telecomun & Energy Labs, 6 Yawatakaigan Dori, Ichihara, Chiba 2908555, Japan
[2] Kyoto Univ, Dept Elect Engn, Nishikyo Ku, Kyoto 6158510, Japan
[3] Fujikura, Energy Technol Res Dept, Adv Technol Lab, 1440 Mutsuzaki, Sakura, Chiba 2858550, Japan
[4] Showa Cable Syst Co Ltd, Superconductor Technol Ctr, Chuo Ku, 1-1 Minami Hashimoto 4 Chome, Sagamihara, Kanagawa 2520253, Japan
[5] Sumitomo Elect, Superconduct Technol Div, Konohana Ku, 1-1-3 Shimaya, Osaka 5540024, Japan
[6] Tokyo Elect Power Co Holdings, TEPCO Res Inst, Tsurumi Ku, 4-1 Egasaki Cho, Yokohama, Kanagawa 2308510, Japan
[7] Japanese Elect Wire & Cable Makers Assoc, Japan Natl Comm IEC TC90 Superconduct, Chuo Ku, Konwa Bldg,1-12-22 Tsukiji, Tokyo 1040045, Japan
关键词
D O I
10.1088/1742-6596/897/1/012021
中图分类号
O414.1 [热力学];
学科分类号
摘要
High-temperature superconducting power cables (HTS cables) have been developed for more than 20 years. In addition of the cable developments, the test methods of the HTS cables have been discussed and proposed in many laboratories and companies. Recently the test methods of the HTS cables is required to standardize and to common in the world. CIGRE made the working group (B1-31) for the discussion of the test methods of the HTS cables as a power cable, and published the recommendation of the test method. Additionally, IEC TC20 submitted the New Work Item Proposal (NP) based on the recommendation of CIGRE this year, IEC TC20 and IEC TC90 started the standardization work on Testing of HTS AC cables. However, the individual test method that used to measure a performance of HTS cables hasn't been established as world's common methods. The AC loss is one of the most important properties to disseminate low loss and economical efficient HTS cables in the world. We regard to establish the method of the AC loss measurements in rational and in high accuracy. Japan is at a leading position in the AC loss study, because Japanese researchers have studied on the AC loss technically and scientifically, and also developed the effective technologies for the AC loss reduction. The JP domestic commission of TC90 made a working team to discussion the methods of the AC loss measurements for aiming an international standard finally. This paper reports about the AC loss measurement of two type of the HTS conductors, such as a HTS conductor without a HTS shield and a HTS conductor with a HTS shield. The AC loss measurement method is suggested by the electrical method.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Analysis of AC loss and current distribution characteristics of multi-layer triaxial HTS cable for 3-phase AC power transmission
    Fukui, Satoshi
    Noguchi, Takeshi
    Ogawa, Jun
    Yamaguchi, Mitsugi
    Sato, Takao
    Tsukamoto, Osami
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 135 - 138
  • [23] Economic analysis of a 22.9 kV HTS power cable and conventional AC power cable for an offshore wind farm connections
    Jung, Ga-Eun
    Dinh, Minh-Chau
    Sung, Hae-Jin
    Park, Minwon
    Yu, In-Keun
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2018, 20 (04): : 60 - 64
  • [24] AC Loss in HTS Fusion Cables: Measurements, Modeling, and Scaling Laws
    Bykovsky, Nikolay
    Uglietti, Davide
    Wesche, Rainer
    Bruzzone, Pierluigi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)
  • [25] AC loss measurements in HTS coil assemblies with hybrid coil structures
    Jiang, Zhenan
    Long, Nicholas J.
    Staines, Mike
    Badcock, Rodney A.
    Bumby, Chris W.
    Buckley, Robert G.
    Amemiya, Naoyuki
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2016, 29 (09):
  • [26] Electric Measurement of the Critical Current, AC Loss, and Current Distribution of a Prototype HTS Cable
    Zhu, Jiahui
    Zhang, Zhenyu
    Zhang, Huiming
    Zhang, Min
    Qiu, Ming
    Yuan, Weijia
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)
  • [27] A study on the application effects of HTS power cable in Seoul
    Seong, KC
    Choi, SB
    Cho, JW
    Kim, HJ
    Kwon, YK
    Ryu, KS
    Kim, BT
    Yu, IK
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2367 - 2370
  • [29] Numerical modelling of a HTS cable in AC regime
    Grilli, F
    Stavrev, S
    Dutoit, B
    Spreafico, S
    Tebano, R
    Gömöry, F
    Frolek, L
    Souc, J
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2004, 401 (1-4): : 176 - 181
  • [30] AC loss of a model 5m 2G HTS power cable using wires with NiW substrates
    Vysotsky, V. S.
    Shutov, K. A.
    Nosov, A. A.
    Polyakova, N. V.
    Fetisov, S. S.
    Zubko, V. V.
    Sytnikov, V. E.
    Carter, W. L.
    Fleshler, S.
    Malozemoff, A. P.
    Snitchler, G.
    9TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS 09), 2010, 234