Ex vivo 3D diffusion tensor imaging and quantification of cardiac laminar structure

被引:168
|
作者
Helm, PA
Tseng, HJ
Younes, L
McVeigh, ER
Winslow, RL
机构
[1] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Ctr Cardiovasc Bioinformat & Modeling, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Ctr Imaging Sci, Baltimore, MD 21218 USA
[3] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
关键词
diffusion tensor MRI; myocardial microstructure; anisotropic diffusion; myofiber laminar sheets; cardiac;
D O I
10.1002/mrm.20622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A three-dimensional (3D) diffusion-weighted imaging (DWI) method for measuring cardiac fiber structure at high spatial resolution is presented. The method was applied to the ex vivo reconstruction of the fiber architecture of seven canine hearts. A novel hypothesis-testing method was developed and used to show that distinct populations of secondary and tertiary eigenvalues may be distinguished at reasonable confidence levels (P <= 0.01) within the canine ventricle. Fiber inclination and sheet angles are reported as a function of transmural depth through the anterior, lateral, and posterior left ventricle (LV) free wall. Within anisotropic regions, two consistent and dominant orientations were identified, supporting published results from histological studies and providing strong evidence that the tertiary eigenvector of the diffusion tensor (DT) defines the sheet normal.
引用
收藏
页码:850 / 859
页数:10
相关论文
共 50 条
  • [31] In vivo 3D muscle architecture quantification based on 3D freehand ultrasound and magnetic resonance imaging
    Wang, Zhongzheng
    Destro, Antea
    Petersson, Sven
    Cenni, Francesco
    Wang, Ruoli
    JOURNAL OF BIOMECHANICS, 2023, 152
  • [32] Gastric carcinoma: Evaluation with diffusion-tensor MR imaging and tractography ex vivo
    Yamada, Ichiro
    Hikishima, Keigo
    Miyasaka, Naoyuki
    Kato, Keiji
    Kojima, Kazuyuki
    Kawano, Tatsuyuki
    Ito, Eisaku
    Kobayashi, Daisuke
    Eishi, Yoshinobu
    Okano, Hideyuki
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 144 - 151
  • [33] Quantification using 3D imaging
    Herman, GT
    CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 2001, 42 (01) : 29 - 57
  • [34] 3D quantification of ultrasound images: Application to mouse embryo imaging in vivo
    Vray, D
    Discher, A
    Lefloc'h, J
    Mai, W
    Clarysse, P
    Pham, QC
    Montagnat, J
    Janier, M
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1597 - 1600
  • [35] In vivo isotropic 3D diffusion tensor mapping of the rat brain using diffusion-weighted 3D MP-RAGE MRI
    Numano, T
    Homma, K
    Iwasaki, N
    Hyodo, K
    Nitta, N
    Hirose, T
    MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 287 - 293
  • [36] High-resolution isotropic 3D diffusion tensor Imaging of the human brain
    Golay, X
    Jiang, H
    van Zijl, PCM
    Mori, S
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) : 837 - 843
  • [37] Study of White Matter Anatomy and 3D Tract Reconstruction by Diffusion Tensor Imaging
    Faria, Andreia V.
    Oishi, Kenichi
    Mori, Susumu
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2010, 20 (01) : 51 - 56
  • [38] 3D space-varying coefficient models with application to diffusion tensor imaging
    Heim, S.
    Fahrmeir, L.
    Eilers, P. H. C.
    Marx, B. D.
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2007, 51 (12) : 6212 - 6228
  • [39] Quantification of mechanical vibration during diffusion tensor imaging at 3 T
    Hiltunen, Jaana
    Hari, Riitta
    Jousmaki, Veikko
    Muller, Kiti
    Sepponen, Raimo
    Joensuu, Raimo
    NEUROIMAGE, 2006, 32 (01) : 93 - 103
  • [40] 3D live-imaging reconstruction of the human embryo implantation ex vivo
    Ojosnegros, S.
    Godeau, A.
    Aroca, E.
    Sole, M.
    Parriego, M.
    Boada, M.
    Veiga, A.
    Lesman, A.
    Tchaicheeyan, O.
    Goren, S.
    Seriola, A.
    HUMAN REPRODUCTION, 2022, 37 : I386 - I386