摘要
Objective: Two types of material are used to manufacture double-lumen endobronchial tubes (DLTs): Polyvinylchloride (PVC) and silicon. PVC DLTs (Broncho-Cath) and silicon DLTs (Silbroncho) not only differ in material, but also subtly differ in structure. The goal of this study was to determine whether the incidences of postoperative sore throat and hoarseness differed between PVC DLTs and silicon DLTs. Design: Prospective, single-blind, balanced (1:1), randomized, controlled trial. Setting: Single university hospital. Participants: Sixty ASA I-II patients, aged 20 to 65 years, scheduled for thoracoscopic pulmonary lobectomy. Interventions: Patients were randomized into the Broncho-cath group (group B, n = 30) and the Silbroncho group (group S. n = 30). Intubation was performed with DLT according to the allocated group by an anesthesiologist. Measurements and Main Results: The incidence of sore throat and hoarseness was evaluated at 1 hour and 24 hours after DLT extubation. The intensity of sore throat was assessed by visual analog scale (VAS < 0-10) at 1, 2, 4, 12, and 24 hours after DLT extubation. The incidence of sore throat was significantly lower in group S compared with that in group B at 1 h (30% v 66.7%, p = 0.018) and 24 hours (10% v 43.3%, p = 0.014). No significant difference was observed in the incidence of hoarseness between the 2 groups. The VAS scores for sore throat in group B were significantly higher than those in group S throughout the study (p < 0.05). Conclusions: The use of silicon DLTs resulted in a lower incidence of postoperative sore throat than did the use of PVC DLTs. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [21] Effect of postoperative ultrasound-guided internal superior laryngeal nerve block on sore throat after intubation of double-lumen bronchial tube: a randomized controlled double-blind trial
    Wang, Jingxian
    Chai, Bin
    Zhang, Yujie
    Zheng, Lidong
    Geng, Pengcheng
    Zhan, Li
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [22] Airway injuries after one-lung ventilation: A comparison between double-lumen tube and endobronchial blocker - A randomized, prospective, controlled trial
    Knoll, Heike
    Ziegeler, Stephan
    Schreiber, Jan-Uwe
    Buchinger, Heiko
    Bialas, Patric
    Semyonov, Kirill
    Graeter, Thomas
    Mencke, Thomas
    ANESTHESIOLOGY, 2006, 105 (03) : 471 - 477
  • [23] Oral flurbiprofen spray for postoperative sore throat and hoarseness: a prospective, randomized, double-blind, placebo-controlled study
    Muderris, Togay
    Tezcan, Gunay
    Sancak, Mecit
    Gul, Fatih
    Ugur, Gokcer
    MINERVA ANESTESIOLOGICA, 2019, 85 (01) : 21 - 27
  • [24] A method for addressing right upper lobe obstruction with right-sided double-lumen endobronchial tubes during surgery: a randomized controlled trial
    Yu, Wei
    Wang, Zijian
    Gao, Dapeng
    Zhang, Wei
    Jin, Wen
    Ma, Xuesong
    Qi, Sihua
    BMC ANESTHESIOLOGY, 2018, 18
  • [25] A method for addressing right upper lobe obstruction with right-sided double-lumen endobronchial tubes during surgery: a randomized controlled trial
    Wei Yu
    Zijian Wang
    Dapeng Gao
    Wei Zhang
    Wen Jin
    Xuesong Ma
    Sihua Qi
    BMC Anesthesiology, 18
  • [26] PLACEMENT OF DOUBLE-LUMEN ENDOBRONCHIAL TUBES - CORRELATION BETWEEN CLINICAL IMPRESSIONS AND BRONCHOSCOPIC FINDINGS
    SMITH, GB
    HIRSCH, NP
    EHRENWERTH, J
    BRITISH JOURNAL OF ANAESTHESIA, 1986, 58 (11) : 1317 - 1320
  • [27] Comparison of three videolaryngoscopes for double-lumen tubes intubation in simulated easy and difficult airways: a randomized trial
    El-Tatahan, Mohamed R.
    AL'Ghamdi, Abdulmohsen A.
    Khidr, Alaa M.
    Gaarour, Ihab S.
    MINERVA ANESTESIOLOGICA, 2016, 82 (10) : 1050 - 1058
  • [28] A randomised controlled trial comparing the GlideScope® and the Macintosh laryngoscope for double-lumen endobronchial intubation
    Russell, T.
    Slinger, P.
    Roscoe, A.
    McRae, K.
    Van Rensburg, A.
    ANAESTHESIA, 2013, 68 (12) : 1253 - 1258
  • [29] Effects of Dexmedetomidine as an Adjuvant in Preoperative Ultrasound-Guided Internal Branch of Superior Laryngeal Nerve Block on Postoperative Sore Throat and Hemodynamics in Patients With Double-Lumen Endotracheal Intubation: A Randomized Controlled Trial
    Chen, Zheping
    Zhang, Le
    Lu, Guodong
    Zhang, Yizheng
    Zhao, Dexu
    Zhao, Shanshan
    Zhang, He
    Jin, Yuelong
    Zhao, Xin
    Jin, Yanwu
    JOURNAL OF PAIN RESEARCH, 2025, 18 : 229 - 241
  • [30] ONE-LUMEN VERSUS DOUBLE-LUMEN ENDOBRONCHIAL TUBES IN THORACIC ANESTHESIA - COMPARISON OF BLOOD-GAS TENSIONS
    AALTOSETALA, M
    HEINONEN, J
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1974, 63 (04) : 276 - 283