Overcorrection after excimer laser treatment of myopia and myopic astigmatism

被引:17
|
作者
Vajpayee, RB [1 ]
McCarty, CA [1 ]
Aldred, G [1 ]
Taylor, HR [1 ]
机构
[1] UNIV MELBOURNE,ROYAL VICTORIAN EYE & EAR HOSP,DEPT OPHTHALMOL,MELBOURNE,VIC 3002,AUSTRALIA
关键词
D O I
10.1001/archopht.1996.01100130248002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To study the incidence and associations of overcorrection after excimer laser treatment of myopia and myopic astigmatism. Methods: The study cohort consisted of 645 patients who had photorefractive or photoastigmatic refractive keratectomy done by an excimer laser during a 2-year period. Patients were assessed 1, 3, 6, and 12 months postoperatively. The variables evaluated were visual acuity, refraction, keratometry, and corneal clarity. Results: At 1 month, overcorrection of more than + 1 diopter spherical equivalent (SEQ) was seen in 22% of the eyes. This progressively regressed so that only 8.6% of the 140 eyes that were overcorrected at 1 month were overcorrected at 1 year. Overall, 2.2% of eyes were overcorrected at 1 year. The magnitude of attempted correction and use of topical nonsteroidal anti-inflammatory drugs disclosed a notable association with occurrence of overcorrection at 1, 3, and 6 months. The use of bandage contact lenses also was associated with overcorrection at 1 and a months. After controlling fbr myopia and use of contact lenses, the odds of overcorrection for use of topical nonsteroidal anti-inflammatory drugs at 1, 3, and 6 months were 2.21 (95% confidence limits [CL]=1.49, 3.44), 1.69 (95% CL=0.88, 3.24), and 2.01 (95% CL=0.88, 4.56), respectively. The odds of overcorrection with bandage contact lenses were 1.79 (95% CL=1.05, 3.05) at 1 month and 2.42 (95% CL=1.23, 4.75) at the end of 3 months. No associations were seen between overcorrection and age, gender, surgical technique, or simultaneous astigmatic corrections. Conclusions: Overcorrection is common during the early postlaser treatment period and is associated with degree of myopia, use of nonsteroidal anti-inflammatory drugs, and bandage contact lens wear.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
  • [41] Functional Outcome and Patient Satisfaction after Laser In Situ Keratomileusis for Correction of Myopia and Myopic Astigmatism
    Bamashmus, Mahfouth A.
    Hubaish, Khammash
    Alawad, Mohammed
    Alakhlee, Hisham
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2015, 22 (01) : 108 - 114
  • [42] Outcomes of LASIK for Myopia or Myopic Astigmatism Correction with the FS200 Femtosecond Laser and EX500 Excimer Laser Platform
    Niparugs, Muanploy
    Tananuvat, Napaporn
    Chaidaroon, Winai
    Tangmonkongvoragul, Chulaluck
    Ausayakhun, Somsanguan
    OPEN OPHTHALMOLOGY JOURNAL, 2018, 12 : 63 - 71
  • [43] CustomVue laser in situ keratomileusis for myopia and myopic astigmatism using the Visx S4 excimer laser - Efficacy, predictability, and safety
    Partal, AE
    Manche, EE
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 475 - 479
  • [44] ARCUATE ASTIGMATISM KERATOTOMY COMBINED WITH EXCIMER-LASER (PRK) TO TREAT ASTIGMATISM AND MYOPIA
    MURTA, JN
    PROENCA, R
    MOITA, JRB
    TRAVASSOS, A
    VISION RESEARCH, 1995, 35 : 3112 - 3112
  • [45] Excimer laser treatment for compound myopic astigmatism (PARK): Clinical results at two years.
    Febbraro, JL
    BremondGignac, D
    Aron, B
    Gross, M
    Pallucchini, L
    AronRosa, D
    VISION RESEARCH, 1996, 36 : 1117 - 1117
  • [46] Efficacy, Predictability, and Safety of Laser-Assisted Subepithelial Keratectomy for the Treatment of Myopia and Myopic Astigmatism
    Al-Tobaigy, Faisal M.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (03) : 304 - 308
  • [48] MYOPIC ASTIGMATISM AND SIMPLE MYOPIA CORRECTION
    ARCINIEGAS, A
    AMAYA, LE
    ANNALS OF OPHTHALMOLOGY, 1993, 25 (08): : 298 - 304
  • [49] TREATMENT OF MYOPIC ASTIGMATISM WITH THE 193-NM EXCIMER-LASER UTILIZING APERTURE ELEMENTS
    SPIGELMAN, AV
    ALBERT, WC
    COZEAN, CH
    JOHNSON, DG
    MCDONNELL, PJ
    PENDER, PM
    SHIMMICK, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 : 258 - 261
  • [50] Use of large optical zones with the LADARVision laser for myopia and myopic astigmatism
    Nepomuceno, RL
    Wachler, BSB
    Sato, M
    Scruggs, R
    OPHTHALMOLOGY, 2003, 110 (07) : 1384 - 1390