Nitrate removal from drinking water using direct current or solar powered electrocoagulation

被引:8
|
作者
Apshankar, Kruttika R. [1 ]
Goel, Sudha [1 ]
机构
[1] Indian Inst Technol Kharagpur, Civil Engn Dept, Kharagpur 721302, W Bengal, India
关键词
Regression analysis; Electroflotation; Voltage; pH; Electrolysis; DEFLUORIDATION; GROUNDWATER;
D O I
10.1007/s42452-020-2069-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Nitrate levels are frequently high in ground and surface waters mainly because of anthropogenic activities. Electrocoagulation (EC) is a viable alternative to conventional coagulation in drinking water treatment and has been successfully applied to remove nitrate from drinking water. The objective of this study was to determine optimum operating conditions for maximizing nitrate removal from drinking water using electrocoagulation followed by settling and filtration. Batch experiments were carried out using iron electrodes (mild steel) and four types of water were tested (groundwater, tap water, untreated water from IIT Water Works and double distilled water). Experiments were conducted with direct current (DC) power or solar power. Operating parameters such as initial nitrate concentration, voltage, electrocoagulation time and settling time were varied to determine optimum conditions for achieving maximum removal efficiency. Nitrate removals after electrocoagulation and after settling were determined for all experiments. In 22 DC power experiments with all waters tested, maximum removal efficiencies were 37% (after EC) and 38.21% (after EC and settling). The highest removal efficiency was obtained in double distilled (DD) water at 10 V, initial nitrate concentration of 452 ppm, EC time of 4 h, settling time of 4 h and an initial pH of 9.89. Multiple linear regression analysis of DD water experiments was done. Model 1 based on removal efficiency after EC only was found to be a good fit and was statistically significant. Five solar experiments were carried out and the maximum removal efficiency obtained was 53% with 3 h of electrolysis time. The initial nitrate concentration was 95.53 mg/L, voltage was 14 V and initial pH was 10.8. Electrocoagulation coupled with solar energy can be used in rural areas in decentralized mode.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Nitrate removal from drinking water using direct current or solar powered electrocoagulation
    Kruttika R. Apshankar
    Sudha Goel
    [J]. SN Applied Sciences, 2020, 2
  • [2] Studies on the removal of arsenate from water through electrocoagulation using direct and alternating current
    Vasudevan, Subramanyan
    Lakshmi, Jothinathan
    Sozhan, Ganapathy
    [J]. DESALINATION AND WATER TREATMENT, 2012, 48 (1-3) : 163 - 173
  • [3] Removal of phosphate from landscape water using an electrocoagulation process powered directly by photovoltaic solar modules
    Zhang, Shunxi
    Zhang, Jian
    Wang, Wenqing
    Li, Furong
    Cheng, Xianzhong
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2013, 117 : 73 - 80
  • [4] Removal of nitrate from water by electroreduction and electrocoagulation
    Koparal, AS
    Ögütveren, ÜB
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2002, 89 (01) : 83 - 94
  • [5] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ucar, Ceren
    Baskan, Meltem Bilici
    Pala, Aysegul
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2013, 30 (10) : 1889 - 1895
  • [6] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ceren Ucar
    Meltem Bilici Baskan
    Aysegul Pala
    [J]. Korean Journal of Chemical Engineering, 2013, 30 : 1889 - 1895
  • [7] Electrocoagulation as an efficient technology for nitrate removal from water
    Rabah, Fahid K. J.
    Qrenawi, Luay I.
    Tabash, Tamer M. S.
    [J]. DESALINATION AND WATER TREATMENT, 2022, 270 : 194 - 205
  • [8] Nitrate Removal from Drinking Water by Using Commercial Nanofiltration
    Torabian, A.
    Harandi, M. Shokouhi
    Bidhendi, Gh. R. Nabi
    Ghadimkhani, A.
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (01) : 666 - 672
  • [9] Effect of alternating and direct current in an electrocoagulation process on the removal of cadmium from water
    Vasudevan, S.
    Lakshmi, J.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2012, 65 (02) : 353 - 360
  • [10] Effects of alternating and direct current in electrocoagulation process on the removal of fluoride from water
    Vasudevan, Subramanyan
    Balasingam, Suresh Kannan
    Lakshmi, Jothinathan
    Mohanraj, Subramanian
    Sozhan, Ganapathy
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2011, 86 (03) : 428 - 436