Q-switched 2.94-μm Er:YAG laser trephination with convergent and divergent cut angles for penetrating keratoplasty

被引:3
|
作者
de Souza, RF [1 ]
Seitz, B [1 ]
Langenbucher, A [1 ]
Hofmann-Rummelt, C [1 ]
Schlötzer-Schrehardt, U [1 ]
Viestenz, A [1 ]
Küchle, M [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
penetrating keratoplasty; Er : YAG laser trephination; convergent cut angles; divergent cut angles; thermal damage;
D O I
10.1097/00003226-200308000-00015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study the morphologic properties of perpendicular (P), convergent (C), and divergent (D) cut angles using different speeds of rotations during donor and recipient nonmechanical trephination for experimental penetrating keratoplasty. Methods. With a Q-switched 2.94-mum Er:YAG laser corneal trephination was performed in 150 enucleated porcine eyes using ceramic open masks with 8 "orientation teeth/notches" and an automated globe rotation device allowing different cut angles [0 degree (P), 10 and 20 degrees (C and D)] toward the optical axis and variation of the rotation speed [3, 7, and 11 rotations per minute (rpm)]. The regularity of the cut (I, regular; II, slightly irregular; III, irregular) was assessed by light microscopy. The area of thermal damage and the number and size of "spikes" in the stroma at the superficial, intermediate and deep level of the excision were analyzed using digital images and the Optimas image processing software. Results. The regularity of the cut was classified as 1 in 42%/22% of donor/recipient and as II in 41%/56%, respectively. The thermal damage was least expressed with D20 degree cut angle and donor mask (P < 0.01). With all cut angles and speeds of rotation, thermal damage at the deep level of excision was significantly smaller (P < 0.01). With different speeds of donor rotations, the thermal damage showed no significant difference. With recipient trephination, the thermal damage at the deep level was greatest with 7 rpm (P < 0.01). The number and size of spikes of thermal damage with donor and recipient masks were significantly smaller in the deep stroma (P < 0.01). Conclusions. Q-switched Er:YAG laser trephination with appropriate settings results in low thermal damage zones at the cut margin. Different cut angles and speeds of trephination may affect the cut performance and quality of the excision. In our study, low rotation speed and divergent donor cut angles showed the best results. The cut quality and the small thermal damage with the Q-switched 2.94-mum Er:YAG laser seem to be tolerable for corneal trephination. Therefore, this modality may be a low-cost, easy-to-handle alternative for nonmechanical corneal transplantation in humans.
引用
收藏
页码:562 / 568
页数:7
相关论文
共 50 条
  • [1] Q-switched 2.94 μm Er:YAG laser trephination with convergent and divergent cut angles for penetrating keratoplasty.
    de Souza, RF
    Seitz, B
    Langenbucher, A
    Viestenz, A
    Hofmann-Rummelt, C
    Küchle, M
    Naumann, GOH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S26 - S26
  • [2] Q-switched erbium:YAG laser corneal trephination -: Thermal damage in corneal stroma and cut regularity of nonmechanical Q-switched erbium:YAG laser corneal trephination for penetrating keratoplasty
    Stojkovic, M
    Seitz, B
    Langenbucher, A
    Viestenz, A
    Viestenz, A
    Hofmann-Rummelt, C
    Schlötzer-Schrehardt, U
    Küchle, M
    Naumann, GOH
    [J]. CORNEA, 2004, 23 (01) : 50 - 60
  • [3] Impact of intracameral pressure on donor cut angles in nonmechanical Er:YAG laser trephination for penetrating keratoplasty
    Sauer, R
    Seitz, B
    Mardin, C
    Langenbucher, A
    Hofmann-Rummelt, C
    Viestenz, A
    Küchle, M
    Naumann, GOH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U205 - U205
  • [4] Impact of intracameral pressure on donor cut angles in nonmechanical Er:YAG laser trephination for penetrating keratoplasty
    Sauer, R
    Seitz, B
    Mardin, C
    Lagenbucher, A
    Hofmann-Rummelt, C
    Viestenz, A
    Küchle, M
    Naumann, GOH
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (06) : 396 - 403
  • [5] EXCIMER LASER-193 NM TREPHINATION WITH DIVERGENT CUT ANGLES IN PENETRATING KERATOPLASTY
    SEITZ, B
    LANGENBUCHER, A
    KUS, M
    NAUMANN, GOH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1085 - 1085
  • [6] Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes
    Stojkovic, M
    Seitz, B
    Küchle, M
    Langenbucher, A
    Viestenz, A
    Viestenz, A
    Hofmann-Rummelt, C
    Naumann, GOH
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 241 (08) : 667 - 672
  • [7] Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes
    Milenko Stojkovic
    Berthold Seitz
    Michael Küchle
    Achim Langenbucher
    Arne Viestenz
    Anja Viestenz
    Carmen Hofmann-Rummelt
    Gottfried O. H. Naumann
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2003, 241 : 667 - 672
  • [8] Nonmechanical Q-switched erbium:: YAG laser trephination for penetrating keratoplasty -: Experimental study on human donor corneas
    Stojkovic, M
    Küchle, M
    Seitz, B
    Labgenbucher, A
    Viestenz, A
    Viestenz, A
    Hofmann-Rummelt, C
    Schlötzer-Schrehardt, U
    Naumann, GOH
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (10) : 1415 - 1422
  • [9] High energy (0.8 J) mechanically Q-switched 2.94 μm Er:YAG laser
    Karki, Krishna
    Fedorov, Vladimir
    Martyshkin, Dmitry
    Mirov, Sergey
    [J]. OPTICS EXPRESS, 2021, 29 (03) : 4287 - 4295
  • [10] Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty
    Seitz, B
    Behrens, A
    Langenbucher, A
    Kus, MM
    Naumann, GOH
    [J]. CORNEA, 1998, 17 (04) : 410 - 416