Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes

被引:2
|
作者
Stojkovic, M [1 ]
Seitz, B [1 ]
Küchle, M [1 ]
Langenbucher, A [1 ]
Viestenz, A [1 ]
Viestenz, A [1 ]
Hofmann-Rummelt, C [1 ]
Naumann, GOH [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
D O I
10.1007/s00417-003-0675-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the degree of corneal diameter shrinkage induced by Q-switched mid-infrared laser corneal trephination for penetrating keratoplasty in an experimental model. Methods. Corneal trephination was performed in 80 enucleated porcine eyes fixed in a holder centered on an automated globe rotation device, by Q-switched (2.94 mum) Er:YAG laser along open masks. Four types of masks were used to protect the underlying corneal tissue: metal masks (donor and recipient) and ceramic masks (donor and recipient). Two spot diameters (0.65 mm and 0.96 mm) were combined with two energy settings (40 mJ/pulse and 50 mJ/pulse) for each of the masks used. Repetition rate was fixed at 5 Hz. Diameters of donor buttons/recipient beds (horizontal and vertical) were measured immediately after the trephination and compared to the given mask size. Results. Minimum corneal shrinkage was found in the recipient metal mask group (mean +/- SD=0.3+/-0.4%) with 50 mJ pulse energy and 0.65 mm spot diameter (in the horizontal diameter), while the maximum shrinkage (5.3+/-2.8%) was found in the donor metal mask group with 50 mJ pulse energy and 0.96 mm spot diameter. Corneal shrinkage was less pronounced in recipient beds than in donor buttons (P<0.01). The differences in shrinkage between the use of ceramic and metal masks were insignificant (P>0.05). Mean induced corneal diameter discrepancies between the donor button and the recipient bed (with metal and ceramic masks) were 2.5% and 2.5% in vertical diameter and 3.4% and 2.4% in horizontal diameter. Conclusions. The Q-switched Er:YAG laser experimental corneal trephination for penetrating keratoplasty may induce minor degrees of corneal diameter shrinkage in donor buttons and recipient openings. Oversizing of donor masks by 0.25-0.35 mm (i.e. 3-4% of graft size) may be a valid option to avoid refractive consequences.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 50 条
  • [1] Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes
    Milenko Stojkovic
    Berthold Seitz
    Michael Küchle
    Achim Langenbucher
    Arne Viestenz
    Anja Viestenz
    Carmen Hofmann-Rummelt
    Gottfried O. H. Naumann
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2003, 241 : 667 - 672
  • [2] Q-switched erbium:YAG laser corneal trephination -: Thermal damage in corneal stroma and cut regularity of nonmechanical Q-switched erbium:YAG laser corneal trephination for penetrating keratoplasty
    Stojkovic, M
    Seitz, B
    Langenbucher, A
    Viestenz, A
    Viestenz, A
    Hofmann-Rummelt, C
    Schlötzer-Schrehardt, U
    Küchle, M
    Naumann, GOH
    [J]. CORNEA, 2004, 23 (01) : 50 - 60
  • [3] Nonmechanical Q-switched erbium:: YAG laser trephination for penetrating keratoplasty -: Experimental study on human donor corneas
    Stojkovic, M
    Küchle, M
    Seitz, B
    Labgenbucher, A
    Viestenz, A
    Viestenz, A
    Hofmann-Rummelt, C
    Schlötzer-Schrehardt, U
    Naumann, GOH
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (10) : 1415 - 1422
  • [4] Stromal thermal effects induced by nonmechanical Q-switched Erbium:YAG laser corneal trephination
    Stojkovic, M
    Seitz, B
    Langenbucher, A
    Küchle, M
    Hofmann-Rummelt, C
    Viestenz, A
    Viestenz, A
    Naumann, GOH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S915 - S915
  • [5] Corneal superficial changes in experimental nonmechanical penetrating keratoplasty using the Q-switched Er:YAG laser
    Viestenz, A
    Küchle, M
    Seitz, B
    Langenbucher, A
    Stoikowic, M
    Viestenz, A
    Hofmann-Rummelt, C
    Naumann, GOH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S915 - S915
  • [6] Superficial corneal effects of experimental nonmechanical penetrating keratoplasty using a Q-switched Er:YAG laser
    Viestenz, A
    Küchle, M
    Seitz, B
    Langenbucher, A
    Viestenz, A
    de Souza, RF
    Naumann, GOH
    [J]. CORNEA, 2002, 21 (05) : 501 - 504
  • [7] Orientation teeth in nonmechanical femtosecond laser corneal trephination for penetrating keratoplasty
    Mastropasqua, Leonardo
    Nubile, Mario
    Lanzini, Manuela
    Calienno, Roberta
    Trubiani, Oriana
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (01) : 46 - 49
  • [8] Nonmechanical corneal trephination with the excimer laser improves outcome after penetrating keratoplasty
    Seitz, B
    Langenbucher, A
    Kus, MM
    Küchle, M
    Naumann, GOH
    [J]. OPHTHALMOLOGY, 1999, 106 (06) : 1156 - 1164
  • [9] Free-running erbium:YAG laser for nonmechanical trephination in penetrating keratoplasty:: first results of experimental trephination of human donor corneas
    Küchle, M
    Behrens, A
    Seitz, B
    Langenbucher, A
    Naumann, GOH
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (10) : 875 - 877
  • [10] Free-running erbium:YAG laser for nonmechanical trephination in penetrating keratoplasty: first results of experimental trephination of human donor corneas
    M. Küchle
    Ashley Behrens
    Berthold Seitz
    Achim Langenbucher
    Gottfried O. H. Naumann
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 1999, 237 : 875 - 877