Evaluation of an Automated System for Reading and Interpreting Disk Diffusion Antimicrobial Susceptibility Testing of Fastidious Bacteria

被引:8
|
作者
Idelevich, Evgeny A. [1 ]
Becker, Karsten [1 ]
Schmitz, Janne [2 ]
Knaack, Dennis [1 ]
Peters, Georg [1 ]
Koeck, Robin [1 ]
机构
[1] Univ Hosp Munster, Inst Med Microbiol, Munster, Germany
[2] Univ Hosp Munster, Inst Hyg, Munster, Germany
来源
PLOS ONE | 2016年 / 11卷 / 07期
关键词
VIDEO READER SYSTEM; ZONE READER; OSIRIS;
D O I
10.1371/journal.pone.0159183
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Results of disk diffusion antimicrobial susceptibility testing depend on individual visual reading of inhibition zone diameters. Therefore, automated reading using camera systems might represent a useful tool for standardization. In this study, the ADAGIO automated system (Bio-Rad) was evaluated for reading disk diffusion tests of fastidious bacteria. 144 clinical isolates (68 beta-haemolytic streptococci, 28 Streptococcus pneumoniae, 18 viridans group streptococci, 13 Haemophilus influenzae, 7 Moraxella catarrhalis, and 10 Campylobacter jejuni) were tested on Mueller-Hinton agar supplemented with 5% defibrinated horse blood and 20 mg/L beta-NAD (MH-F, Oxoid) according to EUCAST. Plates were read manually with a ruler and automatically using the ADAGIO system. Inhibition zone diameters, indicated by the automated system, were visually controlled and adjusted, if necessary. Among 1548 isolate-antibiotic combinations, comparison of automated vs. manual reading yielded categorical agreement (CA) without visual adjustment of the automatically determined zone diameters in 81.4%. In 20% (309 of 1548) of tests it was deemed necessary to adjust the automatically determined zone diameter after visual control. After adjustment, CA was 94.8%; very major errors (false susceptible interpretation), major errors (false resistant interpretation) and minor errors (false categorization involving intermediate result), calculated according to the ISO 20776-2 guideline, accounted to 13.7% (13 of 95 resistant results), 3.3% (47 of 1424 susceptible results) and 1.4% (21 of 1548 total results), respectively, compared to manual reading. The ADAGIO system allowed for automated reading of disk diffusion testing in fastidious bacteria and, after visual validation of the automated results, yielded good categorical agreement with manual reading.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation of Automated Disk Diffusion Antimicrobial Susceptibility Testing Using Radian® In-Line Carousel
    Callebaut, Kim
    Stoefs, Anke
    Emmerechts, Kristof
    Vandoorslaer, Kristof
    Wybo, Ingrid
    De Geyter, Deborah
    Demuyser, Thomas
    Pierard, Denis
    Muyldermans, Astrid
    [J]. CURRENT MICROBIOLOGY, 2024, 81 (07)
  • [3] Evaluation of MIDITECH automated colorimetric MIC reading for antimicrobial susceptibility testing
    Gattringer, R
    Niks, M
    Ostertág, R
    Schwarz, K
    Medvedovic, H
    Graninger, W
    Georgopoulos, A
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2002, 49 (04) : 651 - 659
  • [4] Evaluation of an automated system for the identification and antimicrobial susceptibility testing of enterococci
    d'Azevedo, PA
    Dias, CAG
    Gonçalves, ALS
    Rowe, F
    Teixeira, LM
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2001, 40 (04) : 157 - 161
  • [5] Multilaboratory evaluation of disk diffusion antimicrobial susceptibility testing of Neisseria meningitidis isolates
    Jorgensen, James H.
    Crawford, Sharon A.
    Fulcher, Letitia C.
    Glennen, Anita
    Harrington, Susan M.
    Swenson, Jana
    Lynfield, Ruth
    Murray, Patrick R.
    Tenover, Fred C.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (05) : 1744 - 1754
  • [6] Validation of the automated reading and incubation system with sensititre plates for antimicrobial susceptibility testing
    Chapin, KC
    Musgnug, MC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) : 1951 - 1956
  • [7] PalAST: A Cross-Platform Mobile Application for Automated Disk Diffusion Antimicrobial Susceptibility Testing
    AlAgha I.
    Elshawa A.
    Alhayek G.
    Ghabayen M.
    Alkhattib R.
    [J]. International Journal of Interactive Mobile Technologies, 2023, 17 (22): : 85 - 99
  • [8] EVALUATION OF A PROPRIETARY BROTH MEDIUM FOR MICRODILUTION SUSCEPTIBILITY TESTING OF NUTRITIONALLY FASTIDIOUS BACTERIA
    BARRY, AL
    COTTON, JL
    JONES, RN
    PACKER, RR
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 24 (05) : 701 - 704
  • [9] EVALUATION OF THE COBAS-BACT AUTOMATED ANTIMICROBIAL SUSCEPTIBILITY TESTING SYSTEM
    DUPUIS, G
    [J]. EXPERIENTIA, 1986, 42 (01): : 103 - 103
  • [10] Evaluation of a novel automated chemiluminescent assay system for antimicrobial susceptibility testing
    Manome, I
    Ikedo, M
    Saito, Y
    Ishii, KK
    Kaku, M
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 279 - 284