Evaluation of MIDITECH automated colorimetric MIC reading for antimicrobial susceptibility testing

被引:39
|
作者
Gattringer, R
Niks, M
Ostertág, R
Schwarz, K
Medvedovic, H
Graninger, W
Georgopoulos, A
机构
[1] Univ Vienna, Dept Internal Med 1, Div Infect Dis & Chemotherapy, A-1010 Vienna, Austria
[2] Comenius Univ, Sch Med, Inst Microbiol, Bratislava, Slovakia
[3] Comenius Univ, Fac Math Phys & Informat, Dept Comp Sci, Bratislava, Slovakia
关键词
D O I
10.1093/jac/49.4.651
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The MIDITECH colorimetric susceptibility test with automated reading is a modification of the standard broth microdilution method that uses a 3-(4,5-dimetylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) dye for detecting viable bacteria. The method can be applied to non-fastidious aerobic Gram-negative bacteria, staphylococci and Enterococcus faecalis. To assess the reliability of this method, we compared susceptibility data obtained by this test with standard NCCLS microdilution assay results. For this purpose, 15 antibiotics and a well characterized set of 527 Gram-negative and Gram-positive bacterial isolates collected and stored at the Division of Infectious Diseases and Chemotherapy (Vienna General Hospital, Austria), yielding 5751 organism-antibiotic combinations, were analysed in duplicate. The overall essential agreement (+/-1 log(2) dilution) between the MIDITECH and NCCLS methods was 96.18 +/- 0.67%. The colorimetric assay compared with the reference method produced MICs less than or equal to2 log(2) dilutions and greater than or equal to2 log(2) dilutions in 2.34% and 1.48% comparisons, respectively. For 326 Gram-negative bacteria, the absolute interpretative agreement of both methods ranged from 87.12% for ampicillin-sulbactam to 99.85% for meropenem (mean 94.86%); 417 (4.92%) minor, three (0.05%) major and 15 (0.63%) very major errors were found. For 127 staphylococci and 74 E. faecalis isolates, the absolute interpretative agreement ranged from 90.80% for ciprofloxacin to 100% for vancomycin and linezolid (mean 96.96%); 81 (2.77%) minor, three (0.15%) major and eight (0.83%) very major errors were found. For most of the clinically important aerobically growing pathogens, the MIDITECH colorimetric test provided reliable quantitative susceptibility data. The main advantage of this method is simple performance, automated reading and data processing without expensive investments.
引用
收藏
页码:651 / 659
页数:9
相关论文
共 50 条
  • [1] EVALUATION OF ALAMAR COLORIMETRIC MIC METHOD FOR ANTIMICROBIAL SUSCEPTIBILITY TESTING OF GRAM-NEGATIVE BACTERIA
    BAKER, CN
    BANERJEE, SN
    TENOVER, FC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (05) : 1261 - 1267
  • [2] Evaluation of an Automated System for Reading and Interpreting Disk Diffusion Antimicrobial Susceptibility Testing of Fastidious Bacteria
    Idelevich, Evgeny A.
    Becker, Karsten
    Schmitz, Janne
    Knaack, Dennis
    Peters, Georg
    Koeck, Robin
    [J]. PLOS ONE, 2016, 11 (07):
  • [4] Evaluation of an automated system for the identification and antimicrobial susceptibility testing of enterococci
    d'Azevedo, PA
    Dias, CAG
    Gonçalves, ALS
    Rowe, F
    Teixeira, LM
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2001, 40 (04) : 157 - 161
  • [5] Validation of the automated reading and incubation system with sensititre plates for antimicrobial susceptibility testing
    Chapin, KC
    Musgnug, MC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) : 1951 - 1956
  • [6] EVALUATION OF THE COBAS-BACT AUTOMATED ANTIMICROBIAL SUSCEPTIBILITY TESTING SYSTEM
    DUPUIS, G
    [J]. EXPERIENTIA, 1986, 42 (01): : 103 - 103
  • [7] Evaluation of a novel automated chemiluminescent assay system for antimicrobial susceptibility testing
    Manome, I
    Ikedo, M
    Saito, Y
    Ishii, KK
    Kaku, M
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 279 - 284
  • [8] European harmonization of MIC breakpoints for antimicrobial susceptibility testing of bacteria
    Kahlmeter, G
    Brown, DFJ
    Goldstein, FW
    MacGowan, AP
    Mouton, JW
    Österlund, A
    Rodloff, A
    Steinbakk, M
    Urbaskova, P
    Vatopoulos, A
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2003, 52 (02) : 145 - 148
  • [9] Evaluation of a scanner-assisted colorimetric MIC method for susceptibility testing of gram-negative fermentative bacteria
    Rahman, M
    Kühn, I
    Rahman, M
    Olsson-Liljequist, B
    Möllby, R
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (04) : 2398 - 2403
  • [10] A simple colorimetric method for testing antimicrobial susceptibility of biofilmed bacteria
    Shukho Kim
    Mi Jin Kim
    Hee Young Kang
    Sung Yong Seol
    Dong Taek Cho
    Jungmin Kim
    [J]. The Journal of Microbiology, 2010, 48 : 709 - 711