Facilitating cartilage volume measurement using MRI

被引:0
|
作者
Maataoui, Adel [1 ]
Gurung, Jessen [1 ]
Ackermann, Hanns [2 ]
Abolmaali, Nasreddin [3 ]
Kafchitsas, Konstantinos [4 ]
Vogl, Thomas J. [1 ]
Khan, M. Fawad [1 ]
机构
[1] Goethe Univ Frankfurt, Inst Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Inst Epidemiol & Med Stat, D-60590 Frankfurt, Germany
[3] Tech Univ Dresden, Med Fac Carl Gustav Carus, ZIK OncoRay Radiat Res Oncol, D-01307 Dresden, Germany
[4] Johannes Gutenberg Univ Mainz, Dept Orthoped & Orthoped Surg, D-55131 Mainz, Germany
关键词
Cartilage; MR; Arthritis; Knee; SPIN-ECHO MR; ARTICULAR-CARTILAGE; KNEE OSTEOARTHRITIS; THICKNESS MEASUREMENTS; QUANTIFICATION; JOINT;
D O I
10.1016/j.ejrad.2009.05.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare quantitative cartilage volume measurement (CVM) using different slice thicknesses. Materials and methods: Ten knees were scanned with a 1.5 T MRI (Sonata, Siemens, Erlangen, Germany) using a 3D gradient echo sequence (FLASH, fast low-angle shot). Cartilage volume of the medial and lateral tibial plateau was measured by two independent readers in 1.5 mm, 3.0 mm and 5.0 mm slices using the Argus (R) software application. Accuracy and time effectiveness served as control parameters. Results: Determining cartilage volume, time for calculation diminished for the lateral tibial plateau from 384.6 perpendicular to 127.7 s and 379.1 perpendicular to 117.6 s to 214.9 perpendicular to 109.9 s and 213.9 perpendicular to 102.2 s to 122.1 perpendicular to 60.1 s and 126.8 perpendicular to 56.2 s and for themedial tibial plateau from 465.0 +/- 147.7 s and 461.8 +/- 142.7 s to 214.0 +/- 67.9 s and 208.9 +/- 66.2 s to 132.6 +/- 41.5 s and 130.6 +/- 42.0 s measuring 1.5 mm, 3 mm and 5 mm slices, respectively. No statistically significant difference between cartilage volume measurements was observed (p > 0.05) while very good inter-reader correlation was evaluated. Conclusion: CVM using 1.5 mm slices provides no higher accuracy than cartilage volume measurement in 5 mm slices while an overall time saving up to 70% is possible. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 50 条
  • [21] MRI measurement of the temperature in cartilage following laser therapy
    Hendrich, C
    Jakob, PM
    Breitling, T
    Schafer, A
    Berden, A
    Haase, A
    Siebert, WE
    ORTHOPADE, 1996, 25 (01): : 17 - 20
  • [22] The total volume and the complete thickness of articular cartilage determined by MRI
    Xia, Y
    OSTEOARTHRITIS AND CARTILAGE, 2003, 11 (07) : 473 - 474
  • [23] Longitudinal measurement of knee articular cartilage volume in osteoarthritis
    Peterfy, CG
    White, DL
    Zhao, J
    VanDijke, CF
    Genant, HK
    ARTHRITIS AND RHEUMATISM, 1998, 41 (09): : S361 - S361
  • [24] Prestructural cartilage assessment using MRI
    Link, Thomas M.
    Neumann, Jan
    Li, Xiaojuan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (04) : 949 - 965
  • [25] Longitudinal measurement of knee articular cartilage volume in osteoarthritis
    Peterfy, CG
    White, DL
    Zhao, J
    Van Dijke, CF
    Genant, HK
    RADIOLOGY, 1998, 209P : 236 - 237
  • [26] Measurement of the thickness and volume of the cartilage by nuclear magnetic resonance
    不详
    PRESSE MEDICALE, 2002, 31 (29): : 1381 - 1382
  • [27] Measurement of liver blood volume using a macromolecular MRI contrast agent at equilibrium
    Blustajn, J
    Cuenod, CA
    Clement, O
    Siauve, N
    VuilleminBodaghi, V
    Frija, G
    MAGNETIC RESONANCE IMAGING, 1997, 15 (04) : 415 - 421
  • [28] Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI
    Kersemans, Veerle
    Cornelissen, Bart
    Allen, Philip D.
    Beech, John S.
    Smart, Sean C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (06) : 1499 - 1504
  • [29] Volume-localized measurement of oxygen extraction fraction in the brain using MRI
    O'Brien, Caitlin
    Okell, Thomas W.
    Chiew, Mark
    Jezzard, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1412 - 1423
  • [30] Hematoma Volume Measurement in Gradient Echo MRI Using Quantitative Susceptibility Mapping
    Wang, Shuo
    Lou, Min
    Liu, Tian
    Cui, Deqi
    Chen, Xiaomei
    Wang, Yi
    STROKE, 2013, 44 (08) : 2315 - 2317