New frequency weighting of hand-arm vibration

被引:28
|
作者
Tominaga, Y [1 ]
机构
[1] Inst Sci Labour, Miyamae Ku, Kawasaki, Kanagawa 2168501, Japan
关键词
hand-arm vibration; frequency weighting; vibration-induced white finger; frequency influence; multi-variate analysis;
D O I
10.2486/indhealth.43.509
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new frequency weighting method to assess hand-arm vibration exposure is proposed in this paper. The influence of frequency components was first estimated using the method of multivariate analysis, then a simple form of the weighting curve was introduced. Compared with the frequency weighting in the current ISO 5349-1 (2001), the proposed weighting can better explain the relationship between rates of symptoms and vibration exposure among vibrating tool users. Although this new weighting is derived from limited data, it suggests that the current weighting in ISO 5349-1 should be changed to give more weight to the high frequency range and less weight to the low frequency range.
引用
收藏
页码:509 / 515
页数:7
相关论文
共 50 条
  • [31] The simulation of vibration attenuation in the hand-arm sistem
    1600, Politechnica University of Bucharest (75):
  • [32] Cold intolerance and hand-arm vibration syndrome
    Cooke, Roger Anthony
    Lawson, Ian James
    OCCUPATIONAL MEDICINE-OXFORD, 2022, 72 (03): : 152 - 153
  • [33] Exposure to Hand-Arm Vibration in the Australian Workforce
    Lewkowski, Kate
    Ytterstad, Elinor
    Pugliese, Matthew J.
    McCausland, Kahlia
    Heyworth, Jane S.
    Li, Ian W.
    Pettersson, Hans
    Williams, Warwick
    Fritschi, Lin
    ANNALS OF WORK EXPOSURES AND HEALTH, 2021, 65 (06) : 659 - 667
  • [34] SENSORINEURAL STAGES OF THE HAND-ARM VIBRATION SYNDROME
    BRAMMER, AJ
    TAYLOR, W
    LUNDBORG, G
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1987, 13 (04) : 279 - 283
  • [35] PATHOPHYSIOLOGICAL AND HYGIENIC ASPECTS OF HAND-ARM VIBRATION
    PYYKKO, I
    STARCK, J
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1986, 12 (04) : 237 - 241
  • [36] Hand-arm vibration measurements: Why bother?
    Wray, Steve
    Acoustics Bulletin, 2006, 31 (05): : 29 - 31
  • [37] The clinical assessment of hand-arm vibration syndrome
    Pelmear, PL
    OCCUPATIONAL MEDICINE-OXFORD, 2003, 53 (05): : 337 - 341
  • [38] EFFECTS OF IMPULSE VIBRATION ON THE HAND-ARM SYSTEM
    DUPUIS, H
    SCHAFER, N
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1986, 12 (04) : 320 - 322
  • [39] A mouse model for hand-arm vibration syndrome
    Lindsley, WG
    Jensen, N
    Kommineni, C
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 448 - 449
  • [40] A comparative evaluation of hand-arm vibration impacts
    Li, Weidong
    Drisdelle, Linda
    Canadian Acoustics - Acoustique Canadienne, 2019, 47 (03): : 62 - 63