Safety and Efficacy of Sirolimus-Eluting Stent Implantation in Patients With Acute Coronary Syndrome in the Real World

被引:11
|
作者
Kawaguchi, Ren [2 ]
Kimura, Takeshi [1 ]
Morimoto, Takeshi [3 ,4 ]
Oshima, Shigeru [2 ]
Hoshizaki, Hiroshi [2 ]
Kawai, Kazuya [5 ]
Shiode, Nobuo [6 ]
Hiasa, Yoshikazu [7 ]
Mitsudo, Kazuaki [8 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Kyoto, Japan
[2] Gunma Prefectural Cardiovasc Ctr, Div Cardiol, Maebashi, Gunma, Japan
[3] Kyoto Univ, Grad Sch Med, Ctr Med Educ, Kyoto, Japan
[4] Kyoto Univ, Grad Sch Med, Clin Epidemiol Unit, Kyoto, Japan
[5] Chikamori Hosp, Div Cardiol, Kochi, Japan
[6] Matsue Red Cross Hosp, Div Cardiol, Matsue, Shimane, Japan
[7] Red Cross Hosp, Div Cardiol, Komatsushima, Japan
[8] Kurashiki Cent Hosp, Div Cardiol, Kurashiki, Okayama, Japan
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2010年 / 106卷 / 11期
关键词
ACUTE MYOCARDIAL-INFARCTION; BARE-METAL STENTS; UNCOATED STENTS; THROMBOSIS; PLACEMENT;
D O I
10.1016/j.amjcard.2010.07.035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of drug-eluting stents in patients with acute coronary syndrome (ACS), particularly those with acute myocardial infarction (AMI), is controversial owing to concerns about late adverse events. We evaluated the long-term safety of sirolimus-eluting stent implantation in patients with ACS. Of 10,778 patients treated exclusively with a sirolimus-eluting stent in the j-Cypher registry, the 3-year outcomes of 2,308 patients with ACS (953 patients with AM!) were compared to those of 8,470 patients without ACS. Compared to patients without ACS, the patients with ACS had a significantly greater adjusted risk of death or myocardial infarction (hazard ratio [HR] 1.24, 95% confidence interval [CI] 1.12 to 1.37, p <0.0001) and definite or probable stent thrombosis (HR 1.43, 95% CI 1.11 to 1.82, p = 0.006) within the first year after sirolimus-eluting stent implantation. However, after 1 year, patients with ACS no longer had a greater risk of death or myocardial infarction (HR 1.01, 95% CI 0.90 to 1.13, p = 0.87) and stent thrombosis (HR 1.32, 95% CI 0.92 to 1.86, p = 0.13). Of the patients with ACS, those with AMI had a greater risk of death or myocardial infarction (HR 1.33, 95% CI 1.12 to 1.6, p = 0.001) and stent thrombosis (HR 1.57, 95% CI 1.05 to 2.39, p = 0.03) than those with unstable angina pectoris within the first year. However, they had a similar risk of death or myocardial infarction (HR 1.00, 95% CI 0.78 to 1.22, p = 0.83) and stent thrombosis (HR 0.83, 95% CI 0.38 to 1.6, p = 0.59) after 1 year. The risk of late adverse events >1 year after sirolimus-eluting stent implantation was similar between those with and without ACS and between those with AMI and those with unstable angina pectoris. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:1550-1560)
引用
收藏
页码:1550 / 1560
页数:11
相关论文
共 50 条
  • [31] Severe multivessel coronary spasm after sirolimus-eluting stent implantation
    Tomassini, Francesco
    Varbella, Ferdinando
    Gagnor, Andrea
    Infantino, Vincenzo
    Luceri, Stefania
    Conte, Maria Rosa
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (06) : 485 - 488
  • [32] CORONARY ARTERY ANEURYSM FORMATION AFTER SIROLIMUS-ELUTING STENT IMPLANTATION
    Sunman, H.
    Canpolat, U.
    Dural, M.
    Asil, S.
    Hekimsoy, V.
    Kaghazi, Z.
    Ozer, N.
    Aytemir, K.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S171 - S171
  • [33] Safety and effectiveness of sirolimus-eluting stent implantation for in-stent restenosis of the unprotected left main coronary artery
    Kim, Hyun-Sook
    Kim, Young-Hak
    Lee, Seung-Whan
    Park, Duk-Woo
    Lee, Cheol Whan
    Hong, Myeong-Ki
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 124 (01) : 118 - 120
  • [34] Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    Yamamoto, H.
    Aoki, J.
    Tanabe, K.
    Otsuki, S.
    Yachi, S.
    Yagishita, A.
    Onuma, Y.
    Chihara, R.
    Nakajima, H.
    Hara, K.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 751 - 751
  • [35] In-stent restenosis after sirolimus-eluting stent implantation is related to coronary stent fracture
    Lee, S. Y.
    Kim, M. H.
    Ahn, C. M.
    Kim, J. S.
    Choi, D. H.
    Jang, Y. S.
    Chung, N. S.
    Min, P. K.
    Yoon, Y. W.
    Hong, B. K.
    [J]. CIRCULATION, 2007, 116 (16) : 467 - 468
  • [36] Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India
    Kumar, Basant
    Agstam, Sourabh
    Vijay, Jyothi
    Batta, Akash
    [J]. INDIAN HEART JOURNAL, 2021, 73 (06) : 733 - 736
  • [37] Frequency of Stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation
    Lee, Sang-Hee
    Park, Jong-Seon
    Shin, Dong-Gu
    Kim, Young-Jo
    Hong, Gue-Ru
    Kim, Woong
    Shim, Bong-Sup
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04): : 627 - 630
  • [38] Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    Aoki, Jiro
    Nakazawa, Gaku
    Tanabe, Kengo
    Hoye, Angela
    Yamamoto, Hirosada
    Nakayama, Tomohiro
    Onuma, Yoshinobu
    Higashikuni, Yasutomi
    Otsuki, Syuji
    Yagishita, Atsuhiko
    Yachi, Sen
    Nakajima, Hiroyoshi
    Hara, Kazuhiro
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) : 380 - 386
  • [39] Six-month clinical outcomes of Firebird 2 sirolimus-eluting stent implantation in real-world patients with coronary artery diseases
    GE Jun-bo
    ZHANG Feng
    QIAN Ju-ying
    GE Lei
    LIU Xue-bo
    ZHOU Jun
    [J]. 中华医学杂志(英文版), 2011, (06) : 831 - 835
  • [40] The Efficacy of Sirolimus-eluting Stent in Patients with Impaired Glucose Tolerance and Coronary Artery Disease
    Kataoka, Yu
    Kokubu, Nobuaki
    Kasahara, Yoichirou
    Abe, Mitsuru
    Otsuka, Yoritaka
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A33 - A33