Experimental Design of a Nonlinear Control Technique for Three-Phase Shunt Active Power Filter

被引:268
|
作者
Rahmani, Salem [1 ]
Mendalek, Nassar [2 ]
Al-Haddad, Kamal [1 ]
机构
[1] Univ Quebec, Ecole Technol Super, Montreal, PQ H3C 1K3, Canada
[2] Notre Dame Univ, Dept Elect Comp & Commun Engn, Louaize, Lebanon
关键词
Active power filter; control delay compensation; modeling; nonactive load current compensation; nonlinear control; power quality; REFERENCE ADAPTIVE-CONTROL; VOLTAGE-SOURCE; IMPLEMENTATION; MODEL; COMPENSATION; PERFORMANCE; ALGORITHM; PWM;
D O I
10.1109/TIE.2009.2038945
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a nonlinear control technique for a three-phase shunt active power filter (SAPF). The method provides compensation for reactive, unbalanced, and harmonic load current components. A proportional-integral (PI) control law is derived through linearization of the inherently nonlinear SAPF system model, so that the tasks of current control dynamics and dc capacitor voltage dynamics become decoupled. This decoupling allows us to control the SAPF output currents and the dc bus voltage independently of each other, thereby providing either one of these decoupled subsystems a dynamic response that significantly slower than that of the other. To overcome the drawbacks of the conventional method, a computational control delay compensation method, which delaylessly and accurately generates the SAPF reference currents, is proposed. The first step is to extract the SAPF reference currents from the sensed nonlinear load currents by applying the synchronous reference frame method, where a three-phase diode bridge rectifier with R-L load is taken as the nonlinear load, and then, the reference currents are modified, so that the delay will be compensated. The converter, which is controlled by the described control strategy, guarantees balanced overall supply currents, unity displacement power factor, and reduced harmonic load currents in the common coupling point. Various simulation and experimental results demonstrate the high performance of the nonlinear controller.
引用
收藏
页码:3364 / 3375
页数:12
相关论文
共 50 条
  • [21] Passivity-based control of a three-phase shunt hybrid active power filter
    [J]. Lu, W, 1600, Editorial Department of Electric Machines and Control (18):
  • [22] A new PWM control technique applied to three-phase shunt hybrid power filter
    Rahmani, S
    Al-Haddad, K
    Fnaiech, F
    [J]. IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 727 - 732
  • [23] Direct Power Control for three-phase Active Power Filter using Backstepping Technique
    Hallabi, Tahar
    Lachkar, Ibtissam
    Elhaq, Saad Lissane
    [J]. 2018 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND DIAGNOSIS (ICCAD), 2018,
  • [24] Simulation of Three-phase Three-wire Shunt Active Power Filter
    Wang, Jidong
    [J]. 2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 278 - 281
  • [25] Modeling and simulation of nonlinear decoupled control of the three-phase active power filter
    Shi, Feng
    Yue, Yong-Tao
    Zha, Xiao-Ming
    Chen, Yun-Ping
    [J]. Gaodianya Jishu/High Voltage Engineering, 2008, 34 (05): : 935 - 941
  • [26] Adaptive nonlinear control of three-phase shunt active power filters with magnetic saturation
    Ouadi, H.
    Chihab, A. Ait
    Giri, F.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 69 : 104 - 115
  • [27] Feedback linearization control technique applied to a three phase shunt active power filter
    Braiek, MLB
    Fnaiech, F
    Al-Haddad, K
    [J]. IECON'03: THE 29TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1 - 3, PROCEEDINGS, 2003, : 1402 - 1407
  • [28] Three-Phase Grid Connected Shunt Active Power Filter Based on Adaptive Q-LMF Control Technique
    Rai, Kanchan Bala
    Kumar, Narendra
    Singh, Alka
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (08) : 10216 - 10225
  • [29] Application of Adaptive Fuzzy Control in Three-Phase Three-Wire Shunt Active Power Filter
    Xu Changbo
    Wang Rongrong
    Li Chunwen
    [J]. PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 4, 2008, : 402 - 405
  • [30] A new control strategy for three-phase shunt active power filter that based on Source Instantaneous Power
    Riyadi, S.
    Haroen, Y.
    [J]. IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 991 - 994