Optimal performance analysis of a small-size gas-fired air-cooled air conditioner

被引:0
|
作者
Wang, L [1 ]
Chen, GM [1 ]
Wang, Q [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
关键词
adiabatic absorption; heat recovery; heat transfer; mass transfer; COP;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Absorption refrigeration cycle using lithium bromide-water solutions as a working fluid has been increasingly considered one of the most desirable alternatives for electricity-powered compression refrigeration cycle in China. A small size gas-fired air-cooled air-conditioner is developed. The system has two new features of waste heat recovery of condensed water from high-pressure generator and an adiabatic absorber with an air cooler. It helps solve the problems, for example, boost of pressure, temperature and concentration in the generators, increase of risk of crystallization and acceleration of corrosion occurring in the conventional air-cooled falling film absorption refrigeration system. Optimal performance of the device is simulated. The results indicated that the system conserved energy. And COP with heat recovery was 0.058 higher than that without heat recovery. Optimal solution distribution ratio into HG made it achieve the maximum COP.
引用
收藏
页码:945 / 951
页数:7
相关论文
共 50 条
  • [1] Simulation of a new type gas-fired air-cooled air-conditioner
    Wang, Lin
    Xu, Xing
    Ma, Aihua
    Guo, Yonghui
    Zhou, Xiwen
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 637 - 641
  • [2] Thermodynamic performance analysis of gas-fired air-cooled adiabatic absorption refrigeration systems
    Wang, L.
    Chen, G. M.
    Wang, Q.
    Zhong, M.
    APPLIED THERMAL ENGINEERING, 2007, 27 (8-9) : 1642 - 1652
  • [3] Levelling seasonal loads with gas-fired air conditioner
    Jin, Fang
    Duan, Changgui
    Chen, Ming
    Nuantong Kongtiao/HV and AC, 2003, 33 (06):
  • [4] SIMULATION OF THE CHILLED WATER SYSTEM OF GAS-FIRED AIR-CONDITIONER
    Lan, Li
    Zhang, Ling
    Lian, Zhiwei
    Liu, Zhongbing
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1857 - 1864
  • [5] Development and investigation of air-cooled thermoelectric air-conditioner
    Zhang, H.J.
    Dong, X.J.
    Tao, W.Q.
    Feng, Q.Y.
    Zou, T.
    Pan Tao Ti Hsueh Pao/Chinese Journal of Semiconductors, 2001, 22 (02): : 220 - 223
  • [6] GAS-FIRED AIR-CONDITIONING
    OMATA, T
    ASIAN NATURAL GAS - A NEW ERA, 1989, : 401 - 426
  • [7] MARKETING GAS-FIRED AIR CONDITIONING
    WINSON, JT
    MODERN REFRIGERATION AND AIR CONDITIONING, 1968, 71 (841): : 69 - &
  • [8] CALCULATING PERFORMANCE OF A GAS-FIRED COILED TUBE AIR HEATER
    LUCAS, DM
    TOTH, HE
    BRITISH CHEMICAL ENGINEERING, 1971, 16 (07): : 598 - &
  • [9] Thermodynamic analysis of air-cooled gas turbine plants
    Khodak, EA
    Romakhova, GA
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2001, 123 (02): : 265 - 270
  • [10] WHAT FUTURE FOR GAS-FIRED AIR CONDITIONING
    不详
    MODERN REFRIGERATION AND AIR CONDITIONING, 1969, 72 (857): : 23 - &