Experimental and numerical investigation of natural convection in a double skin facade

被引:28
|
作者
Inan, Tugba [1 ]
Basaran, Tahsin [1 ]
Ezan, Mehmet Akif [2 ]
机构
[1] Izmir Inst Technol, Dept Architecture, TR-35430 Izmir, Turkey
[2] Dokuz Eylul Univ, Dept Mech Engn, TR-35397 Izmir, Turkey
关键词
Natural convection; Double skin facade; Differentially heated cavity; Closed cavity; FILLED SQUARE CAVITY; HEAT-TRANSFER; AIR-FLOW;
D O I
10.1016/j.applthermaleng.2016.06.124
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, airflow and heat transfer in a rectangular cavity that simulates a double skin facade and includes natural convection were examined numerically and experimentally. This cavity separates the exterior space and the thermally controlled interior space. The temperatures of the surfaces that interact with these spaces were determined experimentally, while the other surfaces were regarded as adiabatic. With these temperature values, the parameters of the numerical study were defined. After the validation of the numerical model was completed based on experimental studies in the literature, the results related to flow and heat transfer in the cavity were analyzed. The numerical model provided results that agree with the air temperature values found experimentally in the cavity. Accordingly, in natural convection, with Rayleigh numbers ranging from 8.59 * 10(9) to 1.41 * 10(10) and the effect of buoyancy on the regions close to the surface, the increasing tendency of the average Nusselt number from 142.6 to 168.8 was shown. In addition, a correlation between the Rayleigh and Nusselt numbers for a cavity aspect ratio of 8.64 was constructed to evaluate the heat flux; this correlation was also shown graphically. (C) 2016 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:1225 / 1235
页数:11
相关论文
共 50 条
  • [1] Experimental and Numerical Investigation of Forced Convection in a Double Skin Facade
    Inan, Tugba
    Basaran, Tahsin
    Erek, Aytunc
    ENERGIES, 2017, 10 (09):
  • [2] Experimental and numerical natural convection in an asymmetrically heated double vertical facade
    Cherif, Yassine
    Sassine, Emilio
    Lassue, Stephane
    Zalewski, Laurent
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 152 (152)
  • [3] Experimental and numerical investigation of forced convection in a double skin facade by using nodal network approach for Istanbul
    Inan, Tugba
    Basaran, Tahsin
    SOLAR ENERGY, 2019, 183 : 441 - 452
  • [4] Numerical simulation of dynamical aspects of natural convection flow in a double-skin facade
    Popa, Catalin
    Ospir, Dan
    Fohanno, Stephane
    Chereches, Cristian
    ENERGY AND BUILDINGS, 2012, 50 : 229 - 233
  • [5] An experimental and numerical investigation of natural convection melting
    Scanlon, TJ
    Stickland, MT
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2001, 28 (02) : 181 - 190
  • [6] Experimental and numerical analysis of a naturally ventilated double-skin facade
    Souza, L. C. O.
    Souza, H. A.
    Rodrigues, E. F.
    ENERGY AND BUILDINGS, 2018, 165 : 328 - 339
  • [7] Natural ventilation in a double-skin facade
    Gratia, E
    De Herde, A
    ENERGY AND BUILDINGS, 2004, 36 (02) : 137 - 146
  • [8] Modelling natural ventilation in double skin facade
    Angeli, Diego
    Dama, Alessanro
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 1537 - 1542
  • [9] NUMERICAL AND EXPERIMENTAL INVESTIGATION OF UNSTEADY NATURAL CONVECTION IN AN OPEN CHANNEL
    Lau, G. E.
    Timchenko, V.
    Menezo, C.
    Giroux-Julien, S.
    Fossa, M.
    Sanvicente, E.
    Reizes, J.
    Yeoh, G. H.
    PROCEEDINGS OF CHT-12 - ICHMT INTERNATIONAL SYMPOSIUM ON ADVANCES IN COMPUTATIONAL HEAT TRANSFER, 2012, : 1507 - 1525
  • [10] Numerical investigation of fire in the cavity of naturally ventilated double skin facade with venetian blinds
    Huang, Youxian
    Yeboah, Siegfried
    Shao, Jingjing
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2023, 44 (01): : 45 - 61