A microfluidic platform integrating pressure-driven and electroosmotic-driven flow with inline filters for affinity separations

被引:0
|
作者
Leng, Weijia [1 ]
Evans, Kimberly [1 ]
Roper, Michael G. [1 ]
机构
[1] Florida State Univ, Dept Chem & Biochem, 95 Chieftain Way, Tallahassee, FL 32306 USA
基金
美国国家卫生研究院;
关键词
AMYLOID POLYPEPTIDE SECRETION; GLUCAGON-SECRETION; TEMPERATURE-MEASUREMENT; INSULIN-SECRETION; PANCREATIC-ISLETS; ELECTRIC-FIELD; CELLS; CHIP; IMMUNOASSAY; LANGERHANS;
D O I
10.1039/c9ay01758e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pancreatic islets of Langerhans release glucagon to maintain blood glucose levels, and release of this peptide is dysregulated in diabetes mellitus. Although the importance of proper secretion of this peptide has been shown, no measurement of its release at the single islet level has been reported. In previous work, a non-competitive assay for glucagon was developed with a 6 pM limit of detection, low enough to measure from a single islet. To incorporate this method in an online assay, a microfluidic system with several distinct features was developed. To maintain appropriate flow rates in the presence of the high concentration of salt that was required for the assay, a piezo-actuated pressure transducer with inline flow sensors was used to drive sample flow through 80 x 50 mu m (width x depth) channels, while electroosmotic flow was used to gate the sample away from a 15 x 5 mu m separation channel. Flow rates tested in this system were 50-200 nL min(-1) with relative standard deviations (RSDs) ranging from 1-4%. Use of the pressure-driven flow was found to increase the amount of clogs in the system, so a method to incorporate inline filters into the channels was developed. A total of 4 low resistance, inline microfabricated filters were evaluated, with all designs prolonging the operation time of the microfluidic device to more than 4 hours without clogs observed. Use of this system enabled highly reproducible injections (3-6% RSD). During initial incorporation of the non-competitive assay for glucagon, it was determined that Joule heating was problematic and temperature measurements revealed the separation channel increased to more than 50 degrees C during operation. A 3D-printed manifold was used to hold a Peltier cooler in place on the microfluidic device which produced a 2.6-fold improvement in the amount of the noncovalent glucagon complex that was detected compared to without cooling. These features are expected to be useful for not only long-term monitoring of the glucagon release from islets of Langerhans, but has the potential to be applied to a number of other microfluidic separation-based assays as well.
引用
收藏
页码:5768 / 5775
页数:8
相关论文
共 50 条
  • [1] A Network Model for Electroosmotic and Pressure-Driven Flow in Porous Microfluidic Channels
    Garcia-Ros, Gonzalo
    Sanchez-Perez, Juan Francisco
    Valenzuela, Julio
    Conesa, Manuel
    Canovas, Manuel
    [J]. MATHEMATICS, 2022, 10 (13)
  • [2] A microfluidic device for performing pressure-driven separations
    Dutta, Debashis
    Ramsey, J. Michael
    [J]. LAB ON A CHIP, 2011, 11 (18) : 3081 - 3088
  • [3] Dispersion by pressure-driven flow in serpentine microfluidic channels
    Rush, BM
    Dorfman, KD
    Brenner, H
    Kim, S
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (18) : 4652 - 4662
  • [4] Liquid slip and thermal effects on electroosmotic and pressure-driven flow in a microchannel
    Ngoma, Guyh Dituba
    Erchiqui, Fouad
    [J]. PROCEEDINGS OF THE 17TH IASTED INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION, 2006, : 360 - +
  • [5] Effect of pressure-driven flow on electroosmotic flow and electrokinetic mass transport in microchannels
    Yuan, Shuai
    Zhou, Mingyong
    Liu, Xijiang
    Jiang, Bingyan
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 206
  • [6] Analytical solution of mixed electroosmotic and pressure-driven flow in rectangular microchannels
    Yang, Dayong
    [J]. MEMS/NEMS NANO TECHNOLOGY, 2011, 483 : 679 - 683
  • [7] Analysis of combined pressure-driven electroosmotic flow through square microchannels
    Monazami, Reza
    Manzari, Mehrdad T.
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2007, 3 (01) : 123 - 126
  • [8] Analysis of combined pressure-driven electroosmotic flow through square microchannels
    Reza Monazami
    Mehrdad T. Manzari
    [J]. Microfluidics and Nanofluidics, 2007, 3 : 123 - 126
  • [9] Electroosmotic and pressure-driven slip flow of fractional viscoelastic fluids in microchannels
    An, Shujuan
    Tian, Kai
    Ding, Zhaodong
    Jian, Yongjun
    [J]. APPLIED MATHEMATICS AND COMPUTATION, 2022, 425
  • [10] Role of streaming potential on pulsating mass flow rate control in combined electroosmotic and pressure-driven microfluidic devices
    Chakraborty, Jeevanjyoti
    Ray, Subhashis
    Chakraborty, Suman
    [J]. ELECTROPHORESIS, 2012, 33 (03) : 419 - 425