A comparative surface analysis of explanted hip joint prostheses made of different biomedical alloys

被引:0
|
作者
Bermudez-Castaneda, Angela [1 ]
Esguerra Arce, Johanna [2 ]
Esguerra-Arce, Adriana [2 ]
Valentina Vargas-Pabon, Sofia [2 ]
Guillermo Ortiz-Martinez, Juan [3 ]
Leonardo Blanco-Estupinan, David [1 ]
Guillermo Castano, Juan [4 ]
Mischler, Stefano [5 ]
机构
[1] Escuela Colombiana Ingn Julio Garavito, Dept Ingn Mecan, AK 45 205-59, Bucaramanga 14520, Colombia
[2] Escuela Colombiana Ingn Julio Garavito, Dept Ingn Ind, AK 45 205-59, Bucaramanga 14520, Colombia
[3] Clin Univ La Sabana, Autopista Norte 7, Bogota 0815, Colombia
[4] Univ Antioquia, Grp Invest CIDEMAT, Calle 67 53-108, Medellin 1226, Colombia
[5] Ecole Polytech Fed Lausanne, Tribol & Interfacial Chem Grp MER, Route Cantonale PC 1015, Lausanne, Switzerland
关键词
Retrieval explants; tribocorrosion; modular hip joint implants; wear; corrosion;
D O I
10.17533/udea.redin.20210320
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient's body, and facilitated medical revisions. However, modularity leads to the presence of new interfaces created between pieces in contact, raising the issue of degradation. Tribocorrosion phenomena have been identified as the main degradation mechanism due to the mechanical, chemical, and electrochemical conditions acting on the materials. In addition, conditions inside the human body are unclear, regarding electrochemical settings and the interaction between the electrochemical and mechanical action. This work is focused on the degradation of monopolar hip joint implants made from biomedical alloys such as stainless steel, Ti, and CoCr alloys. Three cases are presented and analyzed in terms of the degradation level along the trunnion length. Surface analysis done on a titanium trunnion showed a significant ploughing on the distal part, compared to what was found for stainless steel and cobalt-chromium alloys, which can produce a stuck in this area. Meanwhile, in the proximal part, wear debris is found, which suggests more movement in the internal part. Although few debris particles were identified in CoCr trunnion, a large amount of material inside the contact was observed. This could be related to the ploughing generated in the distal thread pattern, which allowed the material to come inside and outside the contact.
引用
收藏
页码:35 / 47
页数:13
相关论文
共 50 条
  • [41] Comparative Creep Analysis of Spherical Shell Made up of Different Materials
    Verma, G.
    Thakur, P.
    MECHANICS OF SOLIDS, 2022, 57 (05) : 1214 - 1221
  • [42] A comparative study of different below-knee prostheses by dynamic foot pressure analysis
    Nyska, M
    Shabat, S
    Arya, A
    McCabe, C
    Linge, K
    Klenerman, L
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2002, 25 (04) : 341 - 344
  • [43] Comparative Creep Analysis of Spherical Shell Made up of Different Materials
    G. Verma
    P. Thakur
    Mechanics of Solids, 2022, 57 : 1214 - 1221
  • [44] Comparative analysis of different FeCrAl alloys in pressurized water reactors
    Magalhaes, Isabella R.
    Chaves, Lucas V. G.
    de Castro, Victor F.
    Reis, Patricia A. L.
    Costa, Antonella L.
    Veloso, Maria Auxiliadora F.
    Pereira, Claubia
    NUCLEAR ENGINEERING AND DESIGN, 2024, 422
  • [45] Five-year results of two cemented hip stem models each made of two different alloys
    Schweizer, A
    Lüem, M
    Riede, U
    Lindenlaub, P
    Ochsner, PE
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (02) : 80 - 86
  • [46] Five-year results of two cemented hip stem models each made of two different alloys
    A. Schweizer
    M. Lüem
    U. Riede
    P. Lindenlaub
    P. E. Ochsner
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 80 - 86
  • [47] Comparative analysis of the surface properties and corrosion resistance of Co-Cr dental alloys fabricated by different methods
    Xing, Xiaojie
    Hu, Qin
    Liu, Yuan
    Wang, Yinghui
    Cheng, Hui
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 497.e1 - 497.e11
  • [48] Analysis of the Surface Quality of Test Samples Made of Biocompatible Titanium Alloys by Sintering
    Rontescu, Corneliu
    Pacioga, Adrian
    Chivu, Oana Roxana
    Cicic, Dumitru Titi
    Iacobescu, Gabriel
    Semenescu, Augustin
    REVISTA DE CHIMIE, 2016, 67 (10): : 1945 - 1947
  • [49] Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study
    Radek Hart
    Pavel Šváb
    Peter Filan
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 429 - 434
  • [50] Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study
    Hart, Radek
    Svab, Pavel
    Filan, Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) : 429 - 434