Shake table investigations on code non-compliant reinforced concrete frames

被引:12
|
作者
Rizwan, Muhammad [1 ]
Ahmad, Naveed [1 ]
Khan, Akhtar Naeem [1 ]
Qazi, Samiullah [1 ]
Akbar, Junaid [1 ]
Fahad, Muhammad [1 ]
机构
[1] Univ Engn & Technol, Earthquake Engn Ctr, Dept Civil Engn, Peshawar 25120, Khyber Pakhtunk, Pakistan
关键词
Shake table test; SMRF; ACI-318; Damage scale; Response modification factor; Beam-column joints; GRAVITY LOADS; TESTS; PERFORMANCE; EARTHQUAKES; BUILDINGS; DAMAGE;
D O I
10.1016/j.aej.2019.12.047
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Shake-table tests were performed on a code conforming and four non-compliant 1:3 reduced scale two-story RC frames. The models were subjected to 1994 Northridge earthquake acceleration time history, linearly scaled to multiple levels for studying the progressive damages. The code conforming model was observed with plastic hinges at the beam-ends and base of columns on ground story. This frame incurred only slight cracks in the joint panels under extreme shaking. The code-conforming model resisted input excitation with peak horizontal acceleration of 1.0 g before attaining the incipient collapse state. The non-compliant models were observed with plastic hinges in beam/column members, and incurred extensive damages in beam-column joints under extreme shaking. The fully non-compliant frame resisted peak horizontal acceleration of 0.50 g before attaining the incipient collapse state. The response modification factor of code-conforming model is 7.54 that reduced to 2.90 in case of fully non-compliant frame, which was due to the non-compliance of constructions. This was partly due to the reduction in the over-strength of frame (which was about 20%) and partly due to the reduction in ductility of frame (which was about 50%), in comparison to the seismic response parameters given in the seismic code. The less redundant structural system and joint shear hinging are the main reasons resulting in the reduction of overstrength and ductility, respectively. Static force based performance assessment in various seismic zones revealed that the code-conforming frame performance is "OK" while noncomplaint frames performance is "NG" in both seismic zone 3 and zone 4. The present research suggests a reliability/redundancy factor to take in to account in proposing response modification factor for seismic design of structure. This will take care of the construction deficiencies found in the region. This factor can vary from 1.0 (in case of fully compliant structure) to 0.40 (in case of fully non-compliant structure). (C) 2020 Faculty of Engineering, Alexandria University. Production and hosting by Elsevier B.V.
引用
收藏
页码:349 / 367
页数:19
相关论文
共 50 条
  • [41] Shake table tests of reinforced concrete bridge columns that re-center following earthquakes
    Dept. of Civil and Envir. Engrg., University of California at Berkeley, Berkeley, CA, 94720-1710, United States
    Doboku Gakkai Ronbunshuu A, 2006, 4 (713-728)
  • [42] Shake-Table Testing of Deficient Reinforced Concrete Frame Retrofitted with Buckling Restrained Brace
    Rafi, M. M.
    Lodi, S. H.
    Al-Sadoon, Z. A.
    Saatcioglu, M.
    Palermo, D.
    ACI STRUCTURAL JOURNAL, 2021, 118 (03) : 161 - 173
  • [43] Restrained Concrete Members - New Findings from Systematic Investigations with Restraint Frames for Reinforced Concrete
    Turner, Katrin
    Schlicke, Dirk
    Nguyen Viet Tue
    BETON- UND STAHLBETONBAU, 2016, 111 (05) : 301 - +
  • [44] NON-LINEAR BEHAVIOUR OF REINFORCED CONCRETE FRAMES.
    Wong, K.W.
    Yeo, M.F.
    Warner, R.F.
    Transactions of the Institution of Engineers, Australia: Civil Engineering, 1988, CE30 (02): : 57 - 65
  • [45] NON-LINEAR ANALYSIS OF REINFORCED-CONCRETE FRAMES
    HSU, CTT
    MIRZA, MS
    SEA, CSS
    COMPUTERS & STRUCTURES, 1981, 13 (1-3) : 223 - 227
  • [46] Hybrid Reinforced Concrete Frames with Engineering Cementitious Composites: Experimental and Numerical Investigations
    Metawa, Abdulrahman
    Leblouba, Moussa
    Barakat, Samer
    SUSTAINABILITY, 2024, 16 (22)
  • [47] Resilience of code compliant reinforced concrete buildings to progressive collapse: A numerical analysis investigation
    Al-Sadoon, Zaid A.
    Junaid, M. Talha
    Al-Sabouni, Usama
    Abu Dabous, Saleh
    Almaghari, Haytham
    RESULTS IN ENGINEERING, 2024, 24
  • [48] Shake-table testing of a self-centering precast reinforced concrete frame with shear walls
    Lu Xilin
    Yang Boya
    Zhao Bin
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2018, 17 (02) : 221 - 233
  • [49] Shake-table testing of a self-centering precast reinforced concrete frame with shear walls
    Lu Xilin
    Yang Boya
    Zhao Bin
    EarthquakeEngineeringandEngineeringVibration, 2018, 17 (02) : 221 - 233
  • [50] Shake-table testing of a self-centering precast reinforced concrete frame with shear walls
    Xilin Lu
    Boya Yang
    Bin Zhao
    Earthquake Engineering and Engineering Vibration, 2018, 17 : 221 - 233