Estimation of blood pressure variability from 24-hour ambulatory finger blood pressure

被引:52
|
作者
Omboni, S
Parati, G
Castiglioni, P
Di Rienzo, M
Imholz, BPM
Langewouters, GJ
Wesseling, KH
Mancia, G
机构
[1] Osped San Luca, Ist Sci, Ist Auxol Italiano, I-20149 Milan, Italy
[2] Osped San Gerardo, Cattedra Med Interna, Monza, Italy
[3] Univ Milan, Milan, Italy
[4] Fdn Pro Juventute, Ctr Bioingn, Lab Ric Cardiovasc, Milan, Italy
[5] TNO BioMed Instrument, Acad Med Ctr, Amsterdam, Netherlands
关键词
blood pressure; blood pressure monitoring; ambulatory; power spectral analysis; Portapres; blood pressure variability;
D O I
10.1161/01.HYP.32.1.52
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Portapres is a noninvasive, beat-to-beat finger blood pressure (BP) monitor that has been shown to accurately estimate 24-hour intra-arterial BP at normal and high BPs. However, no information is available on the ability of this device to accurately track ambulatory BP variability. In 20 ambulatory normotensive and hypertensive subjects, we measured 24-hour BP by Portapres and through a brachial artery catheter. BP and pulse interval variabilities were quantified by (1) the SDs of the mean values (overall variability) and (2) spectral power, computed either by fast Fourier transform and autoregressive modeling of segments of 120-second duration for spectral components from 0.025 to 0.50 Hz or in a very low frequency range (between 0.00003 and 0.01 Hz) by broadband spectral analysis. The 24-hour SD of systolic BP obtained from Portapres (24+/-2 mm Hg) was greater than that obtained intra-arterially (17+/-1 mm Hg, P<0.01), but the overestimation was less evident for diastolic (3+/-1 mm Hg, P<0.01) and mean (3+/-1 mm Hg, P<0.01) BP. The BP spectral power <0.15 Hz was also overestimated by Portapres more for systolic than for diastolic and mean BPs; similar findings were obtained by the fast Fourier transform, the autoregressive approach, and focusing on the broadband spectral analysis. BP spectral power >0.15 Hz obtained by the Portapres was similar during the day but lower during the night when compared with those obtained by intra-arterial recordings (P<0.01). No differences were observed between Portapres and intra-arterial recordings for any estimation of pulse interval variabilities. The overestimation of BP variability by Portapres remained constant over virtually the entire 24-hour recording period. Thus, although clinical studies are still needed to demonstrate the clinical relevance of finger BP variability, our study shows that Portapres can be used with little error to estimate 24-hour BP variabilities if diastolic and mean BPs are used. For systolic BP, the greater error can be minimized by using correction factors.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 50 条
  • [41] PROGNOSTIC VALUE OF 24-HOUR BLOOD-PRESSURE VARIABILITY
    FRATTOLA, A
    PARATI, G
    CUSPIDI, C
    ALBINI, F
    MANCIA, G
    [J]. JOURNAL OF HYPERTENSION, 1993, 11 (10) : 1133 - 1137
  • [42] Automated office blood pressure is in agreement with awake and mean 24-hour ambulatory blood pressure at the lower blood pressure range
    Andreadis, Emmanuel A.
    Geladari, Charalampia V.
    Angelopoulos, Epameinondas T.
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (07): : 1177 - 1183
  • [43] Blood pressure 24-hour rhythms and variability in adolescents with hypertension
    Olbinskaya, LI
    Morozova, TE
    Ladonkina, EV
    [J]. KARDIOLOGIYA, 2003, 43 (01) : 40 - 43
  • [44] THE INFLUENCE OF 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING ON BLOOD PRESSURE MANAGEMENT IN HYPERTENSIVE PATIENTS.
    Byars, L. A.
    Denton, G.
    Shimeall, W. T.
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 2009, 24 : 187 - 187
  • [45] Is the 24-hour blood pressure variability determined by an internal clock?
    Lemmer, B
    [J]. NIEREN-UND HOCHDRUCKKRANKHEITEN, 2000, 29 (12) : 586 - 588
  • [46] Effect of alcohol cessation on blood pressure.: Assessment by 24-hour ambulatory blood pressure monitoring
    Aguilera, MT
    de la Sierra, A
    Coca, A
    Estruch, R
    Fernández-Solá, J
    Gómez-Angelats, E
    Sierra, C
    Bragulat, E
    Giner, V
    Antonio, MT
    Urbano-Márquez, A
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 148A - 148A
  • [47] DETERMINANTS OF SUBOPTIMAL BLOOD PRESSURE CONTROL IN HYPERTENSIVE PATIENTS: 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING
    Moazenzadeh, Mansoor
    Mirzazadeh, Ali
    Salari, Pooria
    [J]. ARYA ATHEROSCLEROSIS, 2008, 3 (04) : 227 - 232
  • [48] Automated self-initiated blood pressure or 24-hour ambulatory blood pressure monitoring in pregnancy?
    Brown, MA
    McHugh, L
    Mangos, G
    Davis, G
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2004, 111 (01) : 38 - 41
  • [49] SALT RESTRICTION LOWERS RESTING BLOOD-PRESSURE BUT NOT 24-HOUR AMBULATORY BLOOD-PRESSURE
    MOORE, TJ
    KLEIN, R
    [J]. CLINICAL RESEARCH, 1989, 37 (02): : A397 - A397
  • [50] P104 Influence of Age and Gender on 24-Hour Variability of Central Blood Pressure: Findings from the International 24-Hour Ambulatory Aortic Blood Pressure Consortium (I24ABC)
    Thomas Weber
    Athanase Protogerou
    Siegfried Wassertheurer
    Cristina Giannatasio
    Piotr Jankowski
    Yan Li
    Alessandro Maloberti
    Barry McDonnell
    Carmel McEniery
    Maria Lorenza Muiesan
    Janos Nemcsik
    Anna Paini
    Enrique Rodilla
    Ian Wilkinson
    Robert Zweiker
    James Sharman
    [J]. Artery Research, 2018, 24 (1) : 109 - 109