Mechanistic insights into water transport in polymer electrolyte fuel cells with a variation of cell temperature and relative humidity of inlet gas elucidated by operando synchrotron X-ray radiography

被引:27
|
作者
Kato, Akihiko [1 ]
Kato, Satoru [1 ]
Yamaguchi, Satoshi [1 ]
Suzuki, Takahisa [1 ]
Nagai, Yasutaka [1 ]
机构
[1] Toyota Cent Res & Dev Labs Inc, 41-1 Yokomichi, Nagakute, Aichi 4801192, Japan
关键词
Polymer electrolyte fuel cells; Water transport; Operando; Synchrotron X-ray; Radiography; LIQUID-WATER; DIFFUSION LAYERS; IN-SITU; 2-PHASE FLOW; SATURATION; MANAGEMENT; MODEL; DISTRIBUTIONS; NAFION; PEMFC;
D O I
10.1016/j.jpowsour.2021.230951
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Excessive liquid water in the gas diffusion layer (GDL) of polymer electrolyte fuel cells (PEFCs) is known to degrade their performance. PEFCs for automotive applications are required to work over a broad temperature range and over a wide range of relative humidity (RH) levels of the gas in their channels. Time-resolved operando synchrotron X-ray radiography was used to understand the effect of temperature and RH on the condensation and transport of water in PEFCs. The results show that the type of condensation and transport to the channel can be classified into four categories on the basis of the transient behavior of the liquid water distribution. The first category is concurrent liquid and vapor transport, the second is liquid-transport dominated, the third is vaporonly transport, and the fourth is accumulation-only near the ribs. We propose the possibility of oversaturation in the GDL, which is usually not considered in numerical calculations of the water distribution in PEFCs. We also show the possibility that experimental results are inconsistent with continuous water distribution in the in-plane direction, which is predicted under the assumption that the GDL structure is uniform and that capillary pressure transports liquid water in the GDL.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] In situ observation of water distribution and behaviour in a polymer electrolyte fuel cell by synchrotron X-ray imaging
    Mukaide, Taihei
    Mogi, Satoshi
    Yamamoto, Jun
    Morita, Akira
    Koji, Shinnosuke
    Takada, Kazuhiro
    Uesugi, Kentaro
    Kajiwara, Kentaro
    Noma, Takashi
    JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 : 329 - 334
  • [22] Operando X-ray tomography and sub-second radiography for characterizing transport in polymer electrolyte membrane electrolyzer
    Leonard, Emily
    Shum, Andrew D.
    Normile, Stanley
    Sabarirajan, Dinesh C.
    Yared, Dominic G.
    Xiao, Xianghui
    Zenyuk, Iryna V.
    ELECTROCHIMICA ACTA, 2018, 276 : 424 - 433
  • [23] X-ray imaging of water distribution in a polymer electrolyte fuel cell
    Lee, Sang Joon
    Lim, Nam-Yun
    Kim, Seok
    Park, Gu-Gon
    Kim, Chang-Soo
    JOURNAL OF POWER SOURCES, 2008, 185 (02) : 867 - 870
  • [24] Determining the Impact of Dynamic Load Conditions on Interfacial Liquid Water Accumulation in Polymer Electrolyte Membrane Fuel Cell Gas Diffusion Layers Using Synchrotron X-Ray Radiography
    Banerjee, R.
    Ge, N.
    Lee, J.
    George, M. G.
    Liu, H.
    Muirhead, D.
    Shrestha, P.
    Chevalier, S.
    Hinebaugh, J.
    Bazylak, A.
    POLYMER ELECTROLYTE FUEL CELLS 16 (PEFC 16), 2016, 75 (14): : 251 - 259
  • [25] Synchrotron X-ray Radiography as a Highly Precise and Accurate Method for Measuring the Spatial Distribution of Liquid Water in Operating Polymer Electrolyte Membrane Fuel Cells
    Chevalier, S.
    Ge, N.
    George, M. G.
    Lee, J.
    Banerjee, R.
    Liu, H.
    Shrestha, P.
    Muirhead, D.
    Hinebaugh, J.
    Tabuchi, Y.
    Kotaka, T.
    Bazylak, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (02) : F107 - F114
  • [26] Fuel crossover and internal current in polymer electrolyte membrane fuel cell from water visualization using X-ray radiography
    Kim, Jongrok
    Je, Junho
    Kaviany, Massoud
    Son, Sang Young
    Kim, MooHwan
    JOURNAL OF POWER SOURCES, 2011, 196 (20) : 8398 - 8401
  • [27] Feasibility of combining electrochemical impedance spectroscopy and synchrotron X-ray radiography for determining the influence of liquid water on polymer electrolyte membrane fuel cell performance
    Antonacci, P.
    Chevalier, S.
    Lee, J.
    Yip, R.
    Ge, N.
    Bazylak, A.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (46) : 16494 - 16502
  • [28] Understanding water uptake and transport in polymer electrolyte membrane of fuel cells using X-ray microtomography
    Hwang, Gi Suk
    Parkinson, Dilworth Y.
    Kusoglu, Ahmet
    MacDowell, Alastair A.
    Weber, Adam Z.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [29] Combined synchrotron X-ray radiography and tomography study of water transport in gas diffusion layers
    Markoetter, H.
    Manke, I.
    Haussmann, J.
    Arlt, T.
    Klages, M.
    Krueger, P.
    Hartnig, C.
    Scholta, J.
    Mueller, B. R.
    Riesemeier, H.
    Banhart, J.
    MICRO & NANO LETTERS, 2012, 7 (07): : 689 - 692
  • [30] Membrane dehydration with increasing current density at high inlet gas relative humidity in polymer electrolyte membrane fuel cells
    Ge, N.
    Banerjee, R.
    Muirhead, D.
    Lee, J.
    Liu, H.
    Shrestha, P.
    Wong, A. K. C.
    Jankovic, J.
    Tam, M.
    Susac, D.
    Stumper, J.
    Bazylak, A.
    JOURNAL OF POWER SOURCES, 2019, 422 : 163 - 174