An ultradurable and compact rotary blood pump with a magnetically suspended impeller in the radial direction

被引:45
|
作者
Masuzawa, T [1 ]
Kita, T [1 ]
Okada, Y [1 ]
机构
[1] Ibaraki Univ, Fac Engn, Dept Mech Engn, Hitachi, Ibaraki 3168511, Japan
关键词
rotary blood pump; centrifugal pump; magnetic suspension; self-bearing motor; ventricular assist system;
D O I
10.1046/j.1525-1594.2001.025005395.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A magnetically suspended centrifugal blood pump has been developed with a self-bearing motor for long-term ventricular assist systems. The rotor of the self-bearing motor is not only actively suspended in the radial direction, but also is rotated by an electromagnetic field, The pump has a long lifetime because there are no mechanical parts such as seals and motor bearings. An outer rotor mechanism was adopted for the self-bearing motor. The stator was constructed in the central space of the motor. The rotor shaped thin ring was set at the circumferential space of the stator. Six vanes were extended from the upper surface of the rotor toward the center of the pump to construct an open-type impeller. The outer diameter and the height of the impeller are 63 mm and 34 mm. respectively. The magnetic bearing method and the servomotor mechanism were adopted to levitate and rotate the rotor, Radial movements of the rotor and rotation are controlled actively by using electromagnets in the stator. Axial movement and tilt of the rotor are restricted by passive stability to simplify the control. The radial gap between the rotor and the stator is 1 mm. A closed-loop circuit filled with water was used to examine basic performance of the pump. Maximum flow rate and pressure head were 8 L/min and 200 mm Hg, respectively. Maximum amplitude of radial displacement of the impeller was 0.15 mm. The impeller could be suspended completely without touching the casing wall during the entire pumping process. Power consumption of the pump was only 9.5 W to produce a flow rate of 5 L/min against a pressure head of 100 mm Hg. We conclude that the pump has sufficient performance for the implantable ventricular assist system.
引用
收藏
页码:395 / 399
页数:5
相关论文
共 50 条
  • [1] CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    NAKAZEKI, T
    ITOH, H
    [J]. ARTIFICIAL ORGANS, 1992, 16 (03) : 305 - 308
  • [2] Magnetically suspended rotary blood pump with radial type combined motor-bearing
    Masuzawa, T
    Kita, T
    Matsuda, K
    Okada, Y
    [J]. ARTIFICIAL ORGANS, 2000, 24 (06) : 468 - 474
  • [3] A Passive Magnetically and Hydrodynamically Suspended Rotary Blood Pump
    Stoiber, Martin
    Grasl, Christian
    Pirker, Stefan
    Raderer, Franz
    Schistek, Roland
    Huber, Leopold
    Gittler, Philipp
    Schima, Heinrich
    [J]. ARTIFICIAL ORGANS, 2009, 33 (03) : 250 - 257
  • [4] RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    TSUKIYA, T
    NISHIMURA, K
    PARK, CH
    NAKAZEKI, T
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 631 - 634
  • [5] Magnetically suspended centrifugal blood pump with a radial magnetic driver
    Hoshi, H
    Katakoa, K
    Ohuchi, K
    Asama, J
    Shinshi, T
    Shimokohbe, A
    Takatani, S
    [J]. ASAIO JOURNAL, 2005, 51 (01) : 60 - 64
  • [6] The Effects of Ambulatory Accelerations on the Stability of a Magnetically Suspended Impeller for an Implantable Blood Pump
    Paul, Gordon
    Rezaienia, Mohammed Amin
    Rahideh, Akbar
    Munjiza, Ante
    Korakianitis, Theodosios
    [J]. ARTIFICIAL ORGANS, 2016, 40 (09) : 867 - 876
  • [7] Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems
    T Akamatsu
    T Tsukiya
    [J]. Sadhana, 1998, 23 : 597 - 603
  • [8] Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems
    Akamatsu, T
    Tsukiya, T
    [J]. SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 1998, 23 (5-6): : 597 - 603
  • [9] A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller
    Asama, J
    Shinshi, T
    Hoshi, H
    Takatani, S
    Shimokohbe, A
    [J]. ARTIFICIAL ORGANS, 2006, 30 (03) : 160 - 167
  • [10] Dynamic characteristics of a magnetically levitated impeller in a centrifugal blood pump
    Asama, Junichi
    Shinshi, Tadahiko
    Hoshi, Hideo
    Takatani, Setsuo
    Shimokohbe, Akira
    [J]. ARTIFICIAL ORGANS, 2007, 31 (04) : 301 - 311