Inaccuracies inherent in dual-energy X-ray absorptiometry in vivo bone mineral densitometry may flaw osteopenic/osteoporotic interpretations and mislead assessment of antiresorptive therapy effectiveness

被引:54
|
作者
Bolotin, HH [1 ]
机构
[1] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
[2] RMIT Univ, Dept Med Radiat Sci, Bundoora, Vic, Australia
关键词
dual-energy X-ray absorptiometry (DXA); bone mineral density (BMD); DXA BMD inaccuracies; soft tissue anthropometrics; bone marrow; osteoporosis; antiresorptive therapy;
D O I
10.1016/S8756-3282(01)00423-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
New, anatomically realistic simulation studies based on a cadaveric lumbar vertebra and a broad range of soft tissue anthropometric representations have quantitatively delineated inaccuracies inherent in dual-energy X-ray absorptiometry (DXA) in vivo bone mineral density (BMD) methodology. It is found that systematic inaccuracies in DXA BMD measurements may readily exceed +/- 20% at typical in vivo lumbar vertebral sites, especially for osteopenic/osteoporotic, postmenopausal, and elderly patients. These findings are quantitatively compared with extensive clinical evidence of strong, positive correlations between soft tissue anthropometrics and DXA in vivo BMD upon which prior significant bone biology interpretations and implications have been based. The agreement is found to be both qualitatively and quantitatively excellent. Moreover, recent extensive multicenter clinical studies have also exposed new facets of strong Linkages between body mass/percent body fat/body mass index (BMI) and DXA-measured BMD that are particularly relevant to osteopenia/osteoporosis and remedial effectiveness of antiresorptive drug therapy, These seemingly disparate and unrelated diagnostic and prognostic aspects of clinically observed associations between soft tissue anthropometrics and measured vertebral BMD are, in this study, self-consistently shown to share the common origin of being manifestations of systematic inherent inaccuracies in DXA in vivo BMD methodology, without the need to invoke any underlying biologically causal mechanism(s), These inaccuracies arise principally from absorptiometric disparities between the intra- and extraosseous soft tissues within the DXA scan region of interest, The present evaluative comparisons are based exclusively on an incisive and diverse body of clinical data that appears difficult to dismiss or discount. Previous invocations of biologically causal mechanisms responsible for this broad range of observations linking body mass, percent body fat, and/or BMI to measured BMD now appear questionable. This doubtful status has also been extended in the present work to previously reported relationships between antiresorptive therapies and observed changes in DXA-derived BMD, These findings strongly indicate that critical and insightful reassessments of diagnostic/prognostic imputations underpinned by DXA in vivo BMD measurements are warranted. It is suggested that a good deal of what is known of bone fragility, bone densitometry, antiresorptive drug efficacy, and/or other therapeutic regimens, if based on patient-specific in vivo DXA methodology, may prove to be equivocal and tenuous. (C) 2001 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:548 / 555
页数:8
相关论文
共 50 条
  • [21] Phalangeal Densitometry Compared With Dual Energy X-ray Absorptiometry for Assessment of Bone Mineral Density in Elderly Women
    Dhainaut, Alvilde
    Rohde, Gudrun
    Hoff, Mari
    Syversen, Unni
    Haugeberg, Glenn
    JOURNAL OF WOMENS HEALTH, 2011, 20 (12) : 1789 - 1795
  • [22] Evaluation of decision rules for referring women for bone densitometry by dual-energy X-ray absorptiometry
    Cadarette, SM
    Jaglal, SB
    Murray, TM
    McIsaac, WJ
    Joseph, L
    Brown, JP
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (01): : 57 - 63
  • [23] Role of dual-energy X-ray absorptiometry (DEXA) bone densitometry in CAPD patients.
    Johnson, W
    Rigby, RJ
    McIntyre, HD
    Brown, A
    Freeman, J
    KIDNEY INTERNATIONAL, 1996, 50 (04) : 1418 - 1418
  • [24] Bone densitometry of the forearm: Comparison of single-photon and dual-energy X-ray absorptiometry
    Eckert, P
    Casez, JP
    Thiebaud, D
    Schnyder, P
    Burckhardt, P
    BONE, 1996, 18 (06) : 575 - 579
  • [25] Assessing bone mineral density in vivo: Dual energy X-ray absorptiometry
    Hester, PY
    Schreiweis, MA
    Orban, JI
    Mazzuco, H
    Kopka, MN
    Ledur, MC
    Moody, DE
    POULTRY SCIENCE, 2004, 83 (02) : 215 - 221
  • [26] Dual-energy X-ray absorptiometry - is it the gold standard, or is bone mineral density everything?
    Zuchowski, Pawel
    Jeka, Daniel
    REUMATOLOGIA, 2024, 62 (01): : 1 - 3
  • [27] The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals
    Joel T Fuller
    Jane Archer
    Jonathan D Buckley
    Margarita D Tsiros
    Dominic Thewlis
    Skeletal Radiology, 2016, 45 : 135 - 140
  • [28] Dual-energy X-ray absorptiometry studies of bone mineral status in newborn infants
    Koo, WWK
    Walters, J
    Bush, AJ
    Chesney, RW
    Carlson, SE
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 (07) : 997 - 1002
  • [29] AN EVALUATION OF FOREARM BONE-MINERAL MEASUREMENT WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    LARCOS, G
    WAHNER, HW
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (11) : 2101 - 2106
  • [30] The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals
    Fuller, Joel T.
    Archer, Jane
    Buckley, Jonathan D.
    Tsiros, Margarita D.
    Thewlis, Dominic
    SKELETAL RADIOLOGY, 2016, 45 (01) : 135 - 140