Improved techniques for high accuracy isotope ratio measurements of nuclear materials using thermal ionization mass spectrometry

被引:158
|
作者
Richter, S [1 ]
Goldberg, SA [1 ]
机构
[1] US DOE, New Brunswick Lab, Argonne, IL 60439 USA
关键词
isotope ratios; total evaporation; multi-dynamic measurements; TIMS;
D O I
10.1016/S1387-3806(03)00338-5
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A set of new techniques with significantly improved accuracy and precision has been developed and qualified for isotope ratio measurements of nuclear material using thermal ionization mass spectrometry (TIMS). First, we have modified the classical total evaporation technique to provide both high precision and high accuracy for a broader range of isotope ratios. This NBL-modified total evaporation technique acquires isotope ratio data until the entire sample is consumed, similar to the classical total evaporation technique, but also corrects the usually low abundances of isotopes such as U-234 and U-236 for peak tailing contributions originating from the isotope intensities of U-235 and U-238. Using the NBL-modified total evaporation technique, we have analyzed a series of NIST/NBL certified reference materials (CRMs) and report new results. For the U-235/U-238 isotope ratio, the relative standard deviation (RSD) between sample turrets is below 0.01%, based on the analysis of 5-10 samples per sample turret. As a second new development, the NBL-modified total evaporation technique is combined with a multi-dynamic measurement routine that further improves the accuracy of the U-234/U-238 and U-236/U-238 isotope ratio measurements. Multi-dynamic isotope ratio measurements combine the simultaneous detection of multiple isotopes with dynamic cycling of mass in two or more steps. This technique is applied on a new mass spectrometer equipped with a dispersion quadrupole, which for the first time allows the necessary fast switching of the ion beam dispersion during multi-dynamic measurements. The advantage of multi-dynamic compared to static measurements is that the dependence of the isotope ratio results on both the cup efficiencies and the current amplifier gains is eliminated. The result is a higher degree of accuracy for nuclear materials analyses. The impact of the NBL-modified total evaporation and the multi-dynamic measurement techniques on several recent certification projects at NBL is demonstrated for uranium. These techniques have significantly improved reproducibility and accuracy for nuclear safeguards measurements and certification of nuclear materials. They have the potential to improve precision and accuracy for other mass spectrometric applications as well. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:181 / 197
页数:17
相关论文
共 50 条
  • [1] Matrix effects in plutonium isotope ratio measurements using thermal ionization mass spectrometry
    Mathew, Kattathu Joseph
    Ottenfeld, Chelsea
    Levesque, Steven
    Keller, Russ
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (02) : 1005 - 1017
  • [2] Matrix effects in plutonium isotope ratio measurements using thermal ionization mass spectrometry
    Kattathu Joseph Mathew
    Chelsea Ottenfeld
    Steven Levesque
    Russ Keller
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 1005 - 1017
  • [3] Improved techniques and certified reference materials for nuclear and geological isotope ratio measurements
    Richter, S.
    Wellum, R.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A532 - A532
  • [4] New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry
    Louis-Jean, James
    Inglis, Jeremy D.
    Hanson, Susan
    Pollington, Anthony
    Meininger, Daniel
    Reilly, Sean
    Steiner, Robert
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 327 (01) : 317 - 327
  • [5] New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry
    James Louis-Jean
    Jeremy D. Inglis
    Susan Hanson
    Anthony Pollington
    Daniel Meininger
    Sean Reilly
    Robert Steiner
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2021, 327 : 317 - 327
  • [6] Factors influencing the precision and accuracy of Nd isotope measurements by thermal ionization mass spectrometry
    Garcon, Marion
    Boyet, Maud
    Carlson, Richard W.
    Horan, Mary F.
    Auclair, Delphine
    Mock, Timothy D.
    [J]. CHEMICAL GEOLOGY, 2018, 476 : 493 - 514
  • [7] High-precision stable zirconium isotope ratio measurements by double spike thermal ionization mass spectrometry
    Feng, Lanping
    Hu, Wenfeng
    Jiao, Yu
    Zhou, Lian
    Zhang, Wen
    Hu, Zhaochu
    Liu, Yongsheng
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 736 - 745
  • [8] HIGH-FIDELITY IN ISOTOPE RATIO MEASUREMENTS BY RESONANCE IONIZATION MASS-SPECTROMETRY
    MILLER, CM
    FEAREY, BL
    PALMER, BA
    NOGAR, NS
    [J]. RESONANCE IONIZATION SPECTROSCOPY 1988, 1989, 94 : 297 - 300
  • [9] Isotope abundance ratio measurements using femtosecond laser ablation ionization mass spectrometry
    Tulej, Marek
    Neubeck, Anna
    Riedo, Andreas
    Lukmanov, Rustam
    Grimaudo, Valentine
    Ligterink, Niels F. W.
    Ivarsson, Magnus
    Bach, Wolfgang
    de Koning, Coenraad
    Wurz, Peter
    [J]. JOURNAL OF MASS SPECTROMETRY, 2020, 55 (12):
  • [10] High precision isotope ratio measurements on boron by thermal ionization mass spectrometry using Rb2BO2+ ion
    Rao, Radhika M.
    Parab, Ankush R.
    Bhushan, K. Sasi
    Aggarwal, Suresh Kumar
    [J]. ANALYTICAL METHODS, 2011, 3 (02) : 322 - 327