Validation of 3D-laser surface registration for image-guided cranio-maxillofacial surgery

被引:64
|
作者
Hoffmann, J
Westendorff, C
Leitner, C
Bartz, D
Reinert, S
机构
[1] Univ Tubingen Hosp, Dept Oral & Maxillofacial Plast Surg, D-72076 Tubingen, Germany
[2] Univ Tubingen, Wilhelm Schickard Inst Comp Sci, Dept Graph Interact Syst, Tubingen, Germany
关键词
image-guided minimally invasive surgery; laser surface scanning; patient registration; navigation-assisted cranio-maxillofacial surgery;
D O I
10.1016/j.jcms.2004.10.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Image-data-based navigation plays an important role during surgical treatment in anatomically complex areas. Conventional patient-to-image registration techniques on the basis of skin and bone markers require expensive and time-consuming logistic support. A new markerless, high-resolution laser surface scan technique for patient registration has been tested in experimental and clinical settings. Methods: In a phantom study, a skull model was registered with laser scanning and marker-based algorithms. The registration procedure was repeated 25 times in each group. The values for the root mean-square error were calculated as a measure of the deviation of the forecast position from the actual position and the target difference. In a clinical setting, 21 consecutive patients who presented with cranio-maxillofacial disorders were scheduled for navigational surgery using laser surface scanning for patient-to-image registration. Here the accuracy was determined by anatomical landmark localization. Results: In the experimental study, a root mean-square error of 1.3+/-0.14mm, and a mean target deviation of 2.08+/-0.49mm were found for laser scanning. In contrast, a root mean-square error of 0.38+/-0.01mm and a mean target deviation of 0.99+/-0.15mm were found for marker registration. The differences were statistically significant (p < 0.005). A strong correlation between the root mean-square error and the target deviation was found for laser (r = 0.96) and marker registration (r = 0.95). During the 21 clinical procedures, the overall accuracy of laser scan registration determined by the root mean-square error was 1.21+/-0.34mm, and the mean clinical precision was 1.8+/-0.5mm. Conclusions: Three-dimensional laser surface registration offers an interesting approach for selected image-guided procedures in cranio-maxillofacial surgery. (C) 2004 European Association for Cranio-Maxillofacial Surgery.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 50 条
  • [41] Assessment of spline-based 2D-3D registration for image-guided spine surgery
    Zhang, Xuan
    Zheng, Guoyan
    Langlotz, Frank
    Nolte, Lutz-Peter
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2006, 15 (03) : 193 - 199
  • [42] Timing of paired points and surface matching registration in three-dimensional (3D) image-guided spinal surgery
    Nottmeier, Eric W.
    Crosby, Tracey L.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (04): : 268 - 270
  • [43] Automatic and Fast Registration Method for Image-Guided Surgery
    Wen, Xi
    Wang, Hong
    Zhai, Weiming
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2014,
  • [44] 3D-2D Image Registration for Image-guided Surgery by Combining Normalized Cross Correlation and Laplacian Correlation
    Wang, Yang
    Xiao, Ye
    Xu, Congcong
    Yang, Bo
    Zheng, Wenfeng
    Liu, Shan
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 11 - 12
  • [45] Non-invasive 3-D patient registration for image-guided skull base surgery
    Westermann, B
    Hauser, R
    [J]. COMPUTERS & GRAPHICS-UK, 1996, 20 (06): : 793 - 799
  • [46] Cortical surface registration for image-guided neurosurgery using laser-range scanning
    Miga, MI
    Sinha, TK
    Cash, DM
    Galloway, RL
    Weil, RJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (08) : 973 - 985
  • [47] Accuracy and aplicability of laser surface scanning as new registration technique in image-guided neurosurgery
    Krishnan, R
    Raabe, A
    Seifert, V
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 678 - 683
  • [48] Robust surface registration using salient anatomical features in image-guided liver surgery
    Clements, Logan W.
    Cash, David M.
    Chapman, William C.
    Galloway, Robert L., Jr.
    Miga, Michael I.
    [J]. MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [49] Validation of anatomical landmarks-based registration for image-guided surgery: An in-vitro study
    Sun, Yi
    Luebbers, Heinz-Theo
    Agbaje, Jimoh Olubanwo
    Schepers, Serge
    Vrielinck, Luc
    Lambrichts, Ivo
    Politis, Constantinus
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2013, 41 (06) : 522 - 526
  • [50] Augmented reality: 3D image-guided surgery
    Archie Hughes-Hallett
    Philip Pratt
    James Dilley
    Justin Vale
    Ara Darzi
    Erik Mayer
    [J]. Cancer Imaging, 15 (Suppl 1)