A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements

被引:15
|
作者
Sigaud, L. [1 ]
de Jesus, V. L. B. [2 ]
Ferreira, Natalia [3 ]
Montenegro, E. C. [4 ]
机构
[1] Univ Fed Fluminense, Inst Fis, BR-24210346 Niteroi, RJ, Brazil
[2] Inst Fed Educ Ciencia & Tecnol Rio de Janeiro IFR, Campus Nilopolis, BR-26530060 Nilopolis, RJ, Brazil
[3] CEFET RJ, Unidade Maracana, BR-20271110 Rio De Janeiro, RJ, Brazil
[4] Univ Fed Rio de Janeiro UFRJ, Inst Fis, POB 68528, BR-21941972 Rio De Janeiro, RJ, Brazil
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 08期
关键词
ELECTRON-IMPACT IONIZATION; MICROCHANNEL PLATE DETECTOR; LONG MAGNETIC LENSES; RARE-GAS ATOMS; DISSOCIATIVE IONIZATION; DETECTION EFFICIENCIES; MOMENTUM SPECTROSCOPY; POSITIVE-IONS; THRESHOLD; BEAM;
D O I
10.1063/1.4961664
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work, the inclusion of an Einzel-like lens inside the time-of-flight drift tube of a standard mass spectrometer coupled to a gas cell-to study ionization of atoms and molecules by electron impact-is described. Both this lens and a conical collimator are responsible for further focalization of the ions and charged molecular fragments inside the spectrometer, allowing a much better resolution at the time-of-flight spectra, leading to a separation of a single mass-to-charge unit up to 100 a.m.u. The procedure to obtain the overall absolute efficiency of the spectrometer and micro-channel plate detector is also discussed. Published by AIP Publishing.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A TANDEM DOUBLE FOCUSING MASS SPECTROMETER FOR NEUTRON CROSS SECTION MEASUREMENTS
    WHITE, FA
    FORMAN, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 211 - &
  • [32] An increase in the order of spatiotemporal focusing in the time-of-flight mass spectrometer with nonuniform field in the ion-acceleration regions
    V. P. Glashchenko
    Technical Physics, 2016, 61 : 766 - 773
  • [33] An increase in the order of spatiotemporal focusing in the time-of-flight mass spectrometer with nonuniform field in the ion-acceleration regions
    Glashchenko, V. P.
    TECHNICAL PHYSICS, 2016, 61 (05) : 766 - 773
  • [34] Development of a new ion mobility (quadrupole) time-of-flight mass spectrometer
    Ibrahim, Yehia M.
    Baker, Erin S.
    Danielson, William F., III
    Norheim, Randolph V.
    Prior, David C.
    Anderson, Gordon A.
    Belov, Mikhail E.
    Smith, Richard D.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 : 655 - 662
  • [35] A quadrupole ion trap time-of-flight mass spectrometer with a parabolic reflectron
    Doroshenko, VM
    Cotter, RJ
    JOURNAL OF MASS SPECTROMETRY, 1998, 33 (04): : 305 - 318
  • [36] PHOTODISSOCIATION AND ION SPECTROSCOPY IN A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    DUNCAN, MA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 101 - ANYL
  • [37] NEW METHOD FOR FOCUSING ION BUNCHES IN TIME-OF-FLIGHT MASS SPECTROMETERS
    KARATAEV, VI
    SHMIKK, DV
    MAMYRIN, BA
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1972, 16 (07): : 1177 - &
  • [38] Development of a time-of-flight mass spectrometer for ion desorption studies at HiSOR
    Fujii, K
    Taga, D
    Nakashima, Y
    Waki, S
    Sardar, SA
    Yasui, Y
    Wada, S
    Sekitani, T
    Tanaka, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1509 - 1513
  • [39] COMPARISON OF INFRARED PHOTODISSOCIATION IN A FOURIER-TRANSFORM MASS-SPECTROMETER WITH METASTABLE ION DECAY IN A DOUBLE-FOCUSING MASS-SPECTROMETER
    BENSIMON, M
    RAPIN, J
    GAUMANN, T
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (1-2): : 125 - 135
  • [40] ON TIME FOCUSING AND PHASE-SPACE DYNAMICS IN TIME-OF-FLIGHT MASS-SPECTROMETER DESIGN
    STEIN, R
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (1-2): : 29 - 47