Silver ion-regulated ratiometric fluorescence assay for alkaline phosphatase detection based on carbon dots and o-phenylenediamine

被引:9
|
作者
Li, Peihua [1 ]
Liang, Na [1 ]
Liu, Chao [1 ]
Xia, Lian [1 ]
Qu, Fengli [1 ]
Song, Zhi-Ling [2 ]
Kong, Rong-Mei [1 ]
机构
[1] Qufu Normal Univ, Sch Chem & Chem Engn, Qufu 273165, Shandong, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Key Lab Opt Elect Sensing & Analyt Chem Life Sci, Shandong Key Lab Biochem Anal,MOE, Qingdao 266042, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Alkaline phosphatase; Ratiometric fluorescence; Carbon dots; Silver ions; O-phenylenediamine; ASCORBIC-ACID; ENERGY-TRANSFER; PROBE; SENSOR; FACILE;
D O I
10.1016/j.saa.2022.121682
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work, a novel silver ion (Ag+)-regulated ratiometric fluorescence method for the effective and sensitive determination of alkaline phosphatase (ALP) was established based on carbon dots (CDs) and o-phenylenediamine (OPD). OPD can be oxidized by Ag(+ )to generate fluorescent 2, 3-diaminophenazine (DAP). Thus, based on inner-filter effect (IFE) or/and fluorescence resonance energy transfer (FRET) between CDs and DAP, the CDs-Ag+- OPD system can generate dual-emission at 454 nm and 570 nm respectively when excited at 360 nm. The intro-duction of ascorbic acid (AA) can react with Ag+ to produce dehydroascorbic acid (DHAA), which inhibits the generation of DAP, resulting in the fluorescence decrease at 570 nm and fluorescence recovery of CDs at 454 nm. Meanwhile, DHAA can react with OPD to generate quoxaline (QX), which emits strong blue fluorescence at 440 nm, further inhibiting the IFE or/and FRET between CDs and DAP. An obvious ratiometric fluorescence response was observed with the increase of the concentration of AA introduced. Due to the fact that AA can be generated by the enzyme catalysis reaction between ALP and 2-phospho-L-ascorbic acid (AAP), the CDs-Ag+-OPD ratiometric system was applied to the determination of ALP successfully. The ratiometric fluorescence value of F454/F570 increases with increasing ALP concentration, with a linear range of 0.2 to 40 U/L and detection limit of 0.1 U/L. In addition, the CDs-Ag+-OPD ratiometric system was successfully applied to the detection of ALP in human serum samples.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Ratiometric fluorescence and colorimetry dual-mode assay based on manganese dioxide nanosheets for visual detection of alkaline phosphatase activity
    Yang, Qian
    Wang, Xiaoyan
    Peng, Hailong
    Arabi, Maryam
    Li, Jinhua
    Xiong, Hua
    Choo, Jaebum
    Chen, Lingxin
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 302 (302)
  • [42] A ratiometric nanoprobe based on silver nanoclusters and carbon dots for the fluorescent detection of biothiols
    Zhang, Shuming
    Lin, Bixia
    Yu, Ying
    Cao, Yujuan
    Guo, Manli
    Shui, Lingling
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 195 : 230 - 235
  • [43] A ratiometric fluorescent assay for the detection and bioimaging of alkaline phosphatase based on near infrared Ag2S quantum dots and calcein
    Cai, Meifang
    Ding, Caiping
    Wang, Fangfang
    Ye, Mingqiang
    Zhang, Cuiling
    Xian, Yuezhong
    BIOSENSORS & BIOELECTRONICS, 2019, 137 : 148 - 153
  • [44] Carbon Quantum Dots-Based Recyclable Real-Time Fluorescence Assay for Alkaline Phosphatase with Adenosine Triphosphate as Substrate
    Qian, Zhaosheng
    Chai, Lujing
    Tang, Cong
    Huang, Yuanyuan
    Chen, Jianrong
    Feng, Hui
    ANALYTICAL CHEMISTRY, 2015, 87 (05) : 2966 - 2973
  • [45] An ultrasensitive label-free colorimetric assay for glutathione based on Ag+ regulated autocatalytic oxidation of o-phenylenediamine
    Li, Fang
    Liu, Jiachang
    Hu, Yuting
    Deng, Ning
    He, Jianbo
    TALANTA, 2018, 186 : 330 - 336
  • [46] Dual-colored carbon dots-based ratiometric fluorescent sensor for high-precision detection of alkaline phosphatase activity
    Shao, Kang
    Yang, Ye
    Ye, Shiyi
    Gu, Danyu
    Wang, Tao
    Teng, Yuanjie
    Shen, Zhenlu
    Pan, Zaifa
    TALANTA, 2020, 208 (208)
  • [47] Current Progress of Ratiometric Fluorescence Sensors Based on Carbon Dots in Foodborne Contaminant Detection
    Zhang, Jialu
    Chen, Huinan
    Xu, Kaidi
    Deng, Dongmei
    Zhang, Qixian
    Luo, Liqiang
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [48] A ratiometric fluorescence strategy based on copper nanoclusters/carbon dots for sensitive detection of doxorubicin
    Li, Feifei
    Fan, Pengfei
    Chen, Xinbei
    Lin, Xi
    Liu, Can
    Hu, Congcong
    Yang, Shengyuan
    Xiao, Fubing
    LUMINESCENCE, 2022, 37 (06) : 868 - 875
  • [49] Ratiometric fluorescence sensor based on carbon quantum dots for visual detection of hypochlorite ions
    Lu, Yifei
    Wang, Sui
    Guo, Zhiyong
    Hu, Yufang
    JOURNAL OF NANOPARTICLE RESEARCH, 2022, 24 (01)
  • [50] Ratiometric fluorescence sensor based on carbon quantum dots for visual detection of hypochlorite ions
    Yifei Lu
    Sui Wang
    Zhiyong Guo
    Yufang Hu
    Journal of Nanoparticle Research, 2022, 24