Digital Image Correlation and Strain Gauges to Map and Compare Strain in Teeth with Different Quantity and Quality of Remaining Tooth Structure

被引:2
|
作者
Alhamdan, Mai Mohammed [1 ,2 ,3 ]
Knowles, Jonathan Campbell [2 ,4 ,5 ,6 ]
McDonald, Ailbhe [1 ]
机构
[1] UCL, Prosthodont Unit, Dept Restorat Dent, Eastman Dent Inst, London, England
[2] UCL, Div Biomat & Tissue Engn, Eastman Dent Inst, London, England
[3] King Saud Univ, Coll Dent, Dept Prosthet Dent Sci, Riyadh, Saudi Arabia
[4] Dankook Univ, Inst Tissue Regenerat Engn ITREN, Global Res Ctr Regenerat Med, Gyeonggido, South Korea
[5] Dankook Univ, Dept Nanobiomed Sci & BK21 Plus NBM, Global Res Ctr Regenerat Med, Gyeonggido, South Korea
[6] Discoveries Ctr Regenerat & Precis Med, UCL Campus, London, England
关键词
ENDODONTICALLY TREATED TEETH; FINITE-ELEMENT-ANALYSIS; RETAINED CORONAL DENTIN; FRACTURE-RESISTANCE; BIOMECHANICAL BEHAVIOR; RESTORATIVE TECHNIQUE; MAXILLARY PREMOLARS; MARGINAL RIDGE; DIFFERENT POST; DESIGN;
D O I
10.11607/ijp.6044
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate strain in teeth with differing quality and quantity of tooth surface loss by utilizing surface displacement field measured using digital image correlation (DIC) and strain gauges (SG). Materials and Methods: A total of 80 mesio-occlusodistal preparations were carried out in human maxillary premolars. Ten sound premolars served as a control group, and treated samples were divided into two groups of 40 each according to the composition of the prepared walls (composed of either enamel and dentin [E + De] or dentin only [De]). Each group was then divided into four subgroups of 10 each according to the selected cusp height-to-width ratio (A = 2:1 mm; B = 3:1 mm; C = 3:1.5 mm; D = 4.5:1.5 mm). The samples were uni-axially loaded to 130 N, and strain was recorded using DIC and SG. Results: With SG testing, control samples recorded the lowest strain values and were significantly different from all test groups. However, DIC failed to detect strain in control samples, as it was too low. With DIC, group D showed the lowest strain readings among all the dimension groups and was significantly different from groups A and B, but the composition of the remaining tooth structure did not show any significant effects. With SG testing, remaining wall dimension and composition both had significant effects: Group A scored the highest strain at all compositions, and E + De had better resistance to load stresses than De only. Conclusion: For both testing methodologies, height (>= 3 mm) and width (1 to 1.5 mm) of the remaining tooth structure had an effect on strain. Tooth compositions of E + De resisted strain better than De counterparts at all dimensions.
引用
收藏
页码:82 / 90
页数:9
相关论文
共 24 条
  • [1] Strain evaluation of axially loaded collateral ligaments: a comparison of digital image correlation and strain gauges
    Prusa, Gwendolin
    Bauer, Leandra
    Santos, Ines
    Thorwaechter, Christoph
    Woiczinski, Matthias
    Kistler, Manuel
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [2] Strain evaluation of axially loaded collateral ligaments: a comparison of digital image correlation and strain gauges
    Gwendolin Prusa
    Leandra Bauer
    Inês Santos
    Christoph Thorwächter
    Matthias Woiczinski
    Manuel Kistler
    [J]. BioMedical Engineering OnLine, 22
  • [3] The Digital Image Correlation System Accuracy Direct Testing Using Strain Gauges
    Rutkiewicz, Andrzej
    Jakobczak, Artur
    [J]. 2017 BALTIC GEODETIC CONGRESS (BGC GEOMATICS), 2017, : 369 - 373
  • [4] Strain Measurement with Optic Fibers for Structural Health Monitoring of Woven Composites: Comparison with Strain Gauges and Digital Image Correlation Measurements
    Boursier Niutta, Carlo
    Tridello, Andrea
    Ciardiello, Raffaele
    Paolino, Davide S.
    [J]. SENSORS, 2023, 23 (24)
  • [5] Experimental comparative testing of steel structures by strain gauges, Digital Image Correlation and magnetic field methods
    Radkowski, Stanislaw
    Gontarz, Szymon
    Maczak, Jedrzej
    Kujawinska, Malgorzata
    Dymny, Grzegorz
    Malowany, Krzysztof
    [J]. 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND MACHINERY FAILURE PREVENTION TECHNOLOGIES 2011, VOLS 1 AND 2, 2011, : 287 - 300
  • [6] Comparison of different filtering strategies to reduce noise in strain measurement with digital image correlation
    Baldoni, Jacopo
    Lionello, Giacomo
    Zama, Fabiana
    Cristofolini, Luca
    [J]. JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2016, 51 (06): : 416 - 430
  • [7] THERMAL STRAIN MEASUREMENT OF A DOUBLE RING STRUCTURE USING DIGITAL IMAGE CORRELATION METHOD
    Jin, Tailie
    Goo, Nam Seo
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2011, 25 (31): : 4269 - 4272
  • [8] Thermal Strain Measurement of a Double Ring Structure using Digital Image Correlation Method
    Jin, Tailie
    Goo, Nam Seo
    Kim, Won-Seop
    Lee, Jinho
    [J]. 2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 1015 - 1019
  • [9] Train passenger car floor panel testing using digital image correlation and strain gauges and comparison with finite element modelling
    Braga, Daniel F. O.
    Ramos, Tiago
    Eslami, Shayan
    Tavares, Paulo J.
    Infante, V.
    de Castro, Paulo M. S. T.
    Moreira, P. M. G. P.
    [J]. ENGINEERING FAILURE ANALYSIS, 2016, 69 : 108 - 121
  • [10] Using digital image correlation to measure displacement and strain during involving distal movement of anterior teeth with clear aligner
    Sawamura, Moeka
    Nakano, Haruhisa
    Shiogama, Motoya
    Takano, Naoki
    Maki, Kotaro
    [J]. DENTAL MATERIALS JOURNAL, 2023, 42 (04) : 493 - 500