SUPERCAPACITOR DEGRADATION ASSESMENT BY POWER CYCLING AND CALENDAR LIFE TESTS

被引:24
|
作者
Sedlakova, Vlasta [1 ]
Sikula, Josef [1 ]
Majzner, Jiri [1 ]
Sedlak, Petr [1 ]
Kuparowitz, Tomas [1 ]
Buergler, Brandon [2 ]
Vasina, Petr [3 ]
机构
[1] Brno Univ Technol, Cent European Inst Technol, Tech 10, CZ-61600 Brno, Czech Republic
[2] Estec, European Space Agcy, Keplerlaan 1, NL-2200 AG Noordwijk, Netherlands
[3] EGGO Space Sro, Dvorakova 328, Lanskroun 56301, Czech Republic
关键词
supercapacitor equivalent circuit; supercapacitor parameter evaluation; supercapacitor reliability; power cycling life test; calendar life test; REDISTRIBUTION;
D O I
10.1515/mms-2016-0038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Degradation of Supercapacitors (SC) is quantified by accelerated ageing tests. Energy cycling tests and calendar life tests are used since they address the real operating modes. The periodic characterization is used to analyse evolution of the SC parameters as a whole, and its Helmholtz and diffusion capacitances. These parameters are determined before the ageing tests and during 3 x 10(5) cycles of both 75% and 100% energy cycling, respectively. Precise evaluation of the capacitance and Equivalent Series Resistance (ESR) is based on fitting the experimental data by an exponential function of voltage vs. time. The ESR increases linearly with the number (No) of cycles for both 75% and 100% energy cycling, whereas a super-linear increase of ESR vs. time of cycling is observed for the 100% energy cycling. A decrease of capacitance in time had been evaluated for 2000 hours of ageing of SC. A relative change of capacitance is Delta C/C-0 = 16% for the 75% energy cycling test and Delta C/C-0 = 20% for the 100% energy cycling test at temperature 25 degrees C, while Delta C/C-0 = 6% for the calendar test at temperature 22 degrees C for a voltage bias V = 1.0 Vop. The energy cycling causes a greater decrease of capacitance in comparison with the calendar test; such results may be a consequence of increasing the temperature due to the Joule heat created in the SC structure. The charge/discharge current value is the same for both 75% and 100% energy cycling tests, so it is the Joule heat created on both the equivalent series resistance and time-dependent diffuse resistance that should be the source of degradation of the SC structure. The diffuse resistance reaches a value of up to 30 Omega within each 75% energy cycle and up to about 43 Omega within each 100% energy cycle.
引用
收藏
页码:345 / 358
页数:14
相关论文
共 50 条
  • [1] Ageing assessment of supercapacitors during calendar life and power cycling tests
    El Brouji, El Hassane
    Vinassa, Jean-Michel
    Briat, Olivier
    Bertrand, Nicolas
    Deletage, Jean-Yves
    Woirgard, Eric
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 1718 - 1725
  • [2] Impact of Calendar Life and Cycling Ageing on Supercapacitor Performance
    El Brouji, El Hassane
    Briat, Olivier
    Vinassa, Jean-Michel
    Bertrand, Nicolas
    Woirgard, Eric
    IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2009, 58 (08) : 3917 - 3929
  • [3] How supercapacitors reach end of life criteria during calendar life and power cycling tests
    Chaari, R.
    Briat, O.
    Deletage, J. Y.
    Woirgard, E.
    Vinassa, J. -M.
    MICROELECTRONICS RELIABILITY, 2011, 51 (9-11) : 1976 - 1979
  • [4] Comparison between changes of ultracapacitors model parameters during calendar life and power cycling ageing tests
    El Brouji, H.
    Briat, O.
    Vinassa, J. -M.
    Bertrand, N.
    Woirgard, E.
    MICROELECTRONICS RELIABILITY, 2008, 48 (8-9) : 1473 - 1478
  • [5] Novel Experimental Investigation of Supercapacitor Ageing during Combined Life-Endurance and Power-Cycling Tests
    Torregrossa, Dimitri
    Paolone, Mario
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 1779 - 1785
  • [6] Contribution of calendar ageing modes in the performances degradation of supercapacitors during power cycling
    Briat, O.
    Vinassa, J. -M.
    Bertrand, N.
    El Brouji, H.
    Deletage, J. -Y.
    Woirgard, E.
    MICROELECTRONICS RELIABILITY, 2010, 50 (9-11) : 1796 - 1803
  • [7] Calendar and cycling ageing of activated carbon supercapacitor for automotive application
    Gualous, H.
    Gallay, R.
    Al Sakka, M.
    Oukaour, A.
    Tala-Ighil, B.
    Boudart, B.
    MICROELECTRONICS RELIABILITY, 2012, 52 (9-10) : 2477 - 2481
  • [8] Extending both cycling and calendar life
    Kim, Sujin
    Kim, Minkwan
    Choi, Jang Wook
    NATURE ENERGY, 2024, 9 (07): : 769 - 770
  • [9] Thermal cycling impacts on supercapacitor performances during calendar ageing
    Ayadi, M.
    Briat, O.
    Eddahech, A.
    German, R.
    Coquery, G.
    Vinassa, J. M.
    MICROELECTRONICS RELIABILITY, 2013, 53 (9-11) : 1628 - 1631
  • [10] Investigation of die-attach degradation using power cycling tests
    Sarkany, Zoltan
    Vass-Varnai, Andras
    Rencz, Marta
    PROCEEDINGS OF THE 2013 IEEE 15TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE (EPTC 2013), 2013, : 780 - 784