What are risk factors for subsequent fracture after vertebral augmentation in patients with thoracolumbar osteoporotic vertebral fractures

被引:17
|
作者
Chen, Zhi [1 ]
Song, Chenyang [1 ]
Chen, Min [1 ]
Li, Hongxiang [2 ]
Ye, Yusong [3 ]
Liu, Wenge [1 ]
机构
[1] Fujian Med Univ, Union Hosp, Dept Orthoped Surg, Fuzhou 350001, Fujian, Peoples R China
[2] Fujian Med Univ, Union Hosp, Dept Radiol, Fuzhou 350001, Fujian, Peoples R China
[3] Fujian Med Univ, Fuqing Affiliated Hosp, Dept Orthoped Surg, Fuzhou 350001, Fujian, Peoples R China
关键词
Osteoporotic vertebral compression fracture; Vertebroplasty; Kyphoplasty; Refracture; Paraspinal muscle; Spine sagittal alignment; Risk factor; COMPRESSION FRACTURES; PERCUTANEOUS VERTEBROPLASTY; RETROSPECTIVE ANALYSIS; REFRACTURE; CLEFT;
D O I
10.1186/s12891-021-04946-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Due to its unique mechanical characteristics, the incidence of subsequent fracture after vertebral augmentation is higher in thoracolumbar segment, but the causes have not been fully elucidated. This study aimed to comprehensively explore the potential risk factors for subsequent fracture in this region. Methods Patients with osteoporotic vertebral fracture in thoracolumbar segment who received vertebral augmentation from January 2019 to December 2020 were retrospectively reviewed. Patients were divided into refracture group and non-refracture group according to the occurrence of refracture. The clinical information, imaging findings (cement distribution, spine sagittal parameters, degree of paraspinal muscle degeneration) and surgery related indicators of the included patients were collected and compared. Results A total of 109 patients were included, 13 patients in refracture group and 96 patients in non-refracture group. Univariate analysis revealed a significantly higher incidence of previous fracture, intravertebral cleft (IVC) and cement leakage, greater fatty infiltration of psoas (FIPS), fatty infiltration of erector spinae plus multifidus (FIES + MF), correction of body angle (BA), BA restoration rate and vertebral height restoration rate in refracture group. Further binary logistic regression analysis demonstrated previous fracture, IVC, FIPS and BA restoration rate were independent risk factors for subsequent fracture. According to ROC curve analysis, the prediction accuracy of BA restoration rate was the highest (area under the curve was 0.794), and the threshold value was 0.350. Conclusions Subsequent fracture might cause by the interplay of multiple risk factors. The previous fracture, IVC, FIPS and BA restoration rate were identified as independent risk factors. When the BA restoration rate exceeded 0.350, refractures were more likely to occur.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Development and validation of a nomogram for predicting the probability of new vertebral compression fractures after vertebral augmentation of osteoporotic vertebral compression fractures
    Li, Qiujiang
    Long, Xingxia
    Wang, Yinbin
    Fang, Xiaomin
    Guo, Donggeng
    Lv, Jinhan
    Hu, Xuehua
    Cai, Lijun
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [42] Risk factors for newly developed osteoporotic vertebral compression fractures following treatment for osteoporotic vertebral compression fractures
    Lee, Bong Gun
    Choi, Jung-Hwan
    Kim, Dong-Yun
    Choi, Won Rak
    Lee, Seung Gun
    Kang, Chang-Nam
    [J]. SPINE JOURNAL, 2019, 19 (02): : 301 - 305
  • [43] Revision surgery after cement augmentation for osteoporotic vertebral fracture
    Hu, Xudong
    Jiang, Weiyu
    Chen, Yunlin
    Wang, Yang
    Ma, Weihu
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (07)
  • [44] What is the role of vertebral augmentation for osteoporotic fractures? A review of the recent literature
    Marcia, Stefano
    Muto, Mario
    Hirsch, Joshua A.
    Chandra, Ronil V.
    Carter, Nicole
    Crivelli, Paola
    Piras, Emanuele
    Saba, Luca
    [J]. NEURORADIOLOGY, 2018, 60 (08) : 777 - 783
  • [45] What is the role of vertebral augmentation for osteoporotic fractures? A review of the recent literature
    Stefano Marcia
    Mario Muto
    Joshua A. Hirsch
    Ronil V. Chandra
    Nicole Carter
    Paola Crivelli
    Emanuele Piras
    Luca Saba
    [J]. Neuroradiology, 2018, 60 : 777 - 783
  • [46] Can MRI predict subsequent pseudarthrosis resulting from osteoporotic thoracolumbar vertebral fractures?
    Hirotsugu Omi
    Toru Yokoyama
    Atsushi Ono
    Takuya Numasawa
    Kanichiro Wada
    Yoichi Fujisawa
    [J]. European Spine Journal, 2014, 23 : 2705 - 2710
  • [47] Risk Factors for New Vertebral Compression Fracture After Percutaneous Vertebral Augmentation: A Retrospective Study
    Zhang, Yunfeng
    Sun, Jiayang J.
    Zhang, Zhuo
    Huang, Fei
    Lv, Jiayin
    Zhu, Qingsan
    [J]. MEDICAL SCIENCE MONITOR, 2023, 29
  • [48] Adjacent vertebral Hounsfield unit value of acute osteoporotic vertebral fracture is a risk factor for concomitant domino osteoporotic vertebral fractures
    Yamaura, Tetsuto
    Maruo, Keishi
    Arizumi, Fumihiro
    Kishima, Kazuya
    Yoshie, Norichika
    Kusukawa, Tomoyuki
    Tachibana, Toshiya
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (03) : 536 - 542
  • [49] Can MRI predict subsequent pseudarthrosis resulting from osteoporotic thoracolumbar vertebral fractures?
    Omi, Hirotsugu
    Yokoyama, Toru
    Ono, Atsushi
    Numasawa, Takuya
    Wada, Kanichiro
    Fujisawa, Yoichi
    [J]. EUROPEAN SPINE JOURNAL, 2014, 23 (12) : 2705 - 2710
  • [50] Filler materials for augmentation of osteoporotic vertebral fractures
    Arabmotlagh, M.
    Rauschmann, M.
    [J]. ORTHOPADE, 2010, 39 (07): : 687 - 692