Diagnostic accuracy of the real-time PCR cobas® Liat® Influenza A/B assay and the Alere i Influenza A & B NEAR isothermal nucleic acid amplification assay for the detection of influenza using adult nasopharyngeal specimens

被引:32
|
作者
Young, Stephen [1 ]
Illescas, Patrick [1 ]
Nicasio, Joclin [1 ]
Sickler, Joanna Jackson [2 ]
机构
[1] TriCore Reference Labs, 1001 Woodward Pl NE, Albuquerque, NM 87102 USA
[2] Roche Mol Syst, Pleasanton, CA USA
关键词
Influenza virus infection; Point-of-care; Real-time polymerase chain reaction cobas (R) Liat (R) Influenza A/B assay; Alere i Influenza A & B assay; UNITED-STATES; RAPID DETECTION; PERFORMANCE; VIRUSES; PREVENTION; SEASON;
D O I
10.1016/j.jcv.2017.07.012
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Accurate detection of influenza requires diagnostic testing; however, methods such as RADTs and central laboratory-based tests are limited by low sensitivity and time constraints, respectively. Objective: To compare the performances of the cobas (R) Liat (R) Influenza A/B and Alere (TM) i Influenza A & B point-of-care (POC) assays for detecting influenza A and B viruses using fresh nasopharyngeal specimens with the GenMark Dx (R) Respiratory Viral Panel as the reference method, a FDA cleared IVD PCR test. Study design: A total of 87 samples collected in viral transport medium from adults >= 18 years of age were re-tested on both POC assays (based on the reference PCR method, 29 were influenza A and 18 were influenza B virus positive). Results: The overall sensitivity and specificity of the cobas Influenza A/B for the detection of influenza A and B relative to reference PCR was 97.9% (95% confidence interval [CI] 88.9%, 99.6%) and 97.5% (95% CI: 87.1%, 99.6%), respectively, while the sensitivity of the Alere i Influenza A & B assay relative to the reference PCR method was 63.8% (95% CI: 49.5%, 76.0%) and the specificity was 97.5% (95% CI: 87.1%, 99.6%). The individual sensitivities and specificities of the cobas Influenza A/B assay for influenza A alone and influenza B alone were comparable to those of the reference PCR method (influenza A: sensitivity of 100% [95% CI: 88.3%, 100.0%] and specificity of 98.3% [95% CI: 90.9%, 99.7%]; influenza B: sensitivity of 94.4% [95% CI: 74.2%, 99.0%] and specificity of 100% [95% CI: 94.7%, 100.0%]). For the Alere i Influenza A & B assay, the individual specificities for influenza A and B were comparable to those of the reference PCR method (98.3% [95% CI: 90.9%, 99.7%] and 97.1% [95% CI: 90.0%, 99.2%], respectively), while the individual sensitivities were low relative to reference PCR (55.2% [95% CI: 37.5%, 71.6%] and 72.2% [95% CI: 49.1%, 87.5%], respectively). Conclusion: The cobas Influenza A/B assay demonstrated performance equivalent to laboratory-based PCR, and could replace rapid antigen tests.
引用
收藏
页码:86 / 90
页数:5
相关论文
共 50 条
  • [31] Applicability of a sensitive duplex real-time PCR assay for identifying B/Yamagata and B/Victoria lineages of influenza virus from clinical specimens
    Naixing Zhang
    Shisong Fang
    Ting Wang
    Jianxiong Li
    Xiaowen Cheng
    Cunyou Zhao
    Xin Wang
    Xing Lv
    Chunli Wu
    Renli Zhang
    Jinquan Cheng
    Hong Xue
    Zuxun Lu
    Applied Microbiology and Biotechnology, 2012, 93 : 797 - 805
  • [32] Comparison of a singleplex real-time RT-PCR assay and multiplex respiratory viral panel assay for detection of influenza "A" in respiratory specimens
    Pabbaraju, Kanti
    Wong, Sallene
    Lee, Bonita
    Tellier, Raymond
    Fonseca, Kevin
    Louie, Marie
    Drews, Steven J.
    INFLUENZA AND OTHER RESPIRATORY VIRUSES, 2011, 5 (02) : 99 - 103
  • [33] A newly developed real-time PCR assay for discriminating influenza B virus Yamagata and Victoria lineages
    Wei, Jinli
    Huang, Huaxin
    Qin, Hucheng
    Li, Shanqin
    Xing, Li
    Li, Yanjie
    Cao, Mengli
    Wang, Yanrong
    Bi, Yuhai
    Liu, Yingxia
    Yang, Yang
    JOURNAL OF MEDICAL VIROLOGY, 2020, 92 (12) : 3067 - 3072
  • [34] Multiplex real-time PCR assay for detection of influenza and human respiratory syncytial viruses
    Boivin, G
    Côté, S
    Déry, P
    De Serres, G
    Bergeron, MG
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) : 45 - 51
  • [35] Evaluation of a multiplex real-time reverse transcriptase PCR assay for detection and differentiation of influenza viruses A and B during the 2001-2002 influenza season in Israel
    Hindiyeh, M
    Levy, V
    Azar, R
    Varsano, N
    Regev, L
    Shalev, Y
    Grossman, Z
    Mendelson, E
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (02) : 589 - 595
  • [36] PERFORMANCE OF THE COBAS (R) INFLUENZA A/B ASSAY FOR RAPID PCR-BASED DETECTION OF INFLUENZA COMPARED TO PRODESSE ProFlu+ AND VIRAL CULTURE
    Chen, L.
    Tian, Y.
    Chen, S.
    Liesenfeld, O.
    EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2015, 5 (04): : 236 - 245
  • [37] Diagnostic accuracy and cost analysis of the Alere™ i Influenza A&B near-patient test using throat swabs
    Davis, S.
    Allen, A. J.
    O'Leary, R.
    Power, M.
    Price, D. A.
    Simpson, A. J.
    Tunbridge, A.
    Vale, L.
    Whiteside, M.
    Evans, C.
    Raza, M.
    JOURNAL OF HOSPITAL INFECTION, 2017, 97 (03) : 301 - 309
  • [38] Evaluation of focus diagnostics KINEDx Flu/RSV real-time PCR assay versus prodesse ProFlu-1 real-time PCR assay for the detection of Respiratory Syncytial Virus A/B, influenza A and B viruses
    Chen, J.
    Ramos, A.
    Mai, H.
    Chen, F.
    Eleasar, E.
    Watt, P. M.
    Tabb, M. M.
    Lu, N.
    Aye, M.
    An, S.
    Dempsey, S.
    Cheng, C. S.
    Hogrefe, W.
    Lee, M.
    Kong, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 677 - 677
  • [39] Development of a multiplex real-time RT-PCR assay for simultaneous detection and differentiation of influenza A, B, C, and D viruses
    Zhang, Hewei
    Wang, Yin
    Porter, Elizabeth
    Lu, Nanyan
    Li, Yanhua
    Yuan, Fangfeng
    Lohman, Molly
    Noll, Lance
    Zheng, Wanglong
    Stoy, Colin
    Lang, Yuekun
    Huber, Victor C.
    Ma, Wenjun
    Peddireddi, Lalitha
    Fang, Ying
    Shi, Jishu
    Anderson, Gary
    Liu, Xuming
    Bai, Jianfa
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 95 (01) : 59 - 66
  • [40] Droplet Microfluidic Chip Based Nucleic Acid Amplification and Real-Time Detection of Influenza Viruses
    Prakash, R.
    Pabbaraju, K.
    Wong, S.
    Wong, A.
    Tellier, R.
    Kaler, K. V. I. S.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (02) : B3083 - B3093