AVLSI compatible conducting polymer composite based "Electronic nose" chip

被引:0
|
作者
Lewis, NS [1 ]
机构
[1] Arthur Amos Noyes Lab Chem Phys, Div Chem & Chem Engn, Pasadena, CA 91125 USA
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The focus of this work would be to exploit the vapor detection technology developed recently at Caltech that forms the basis for a low power, simple "electronic nose". In this work we have integrated the sensors, signal preprocessing, signal processing, and data analysis functions into a single, low power, low cost, "nose chip". Such a device could be implantable covertly or overtly onto suspect sites, deployable through remote delivery methods, worn by soldiers for CW alerts and in principle for IFF or military/nonmilitary identification purposes, and for other areas of national security where low power, lightweight, small, chemical sensing is of importance.
引用
收藏
页码:485 / 487
页数:3
相关论文
共 50 条
  • [21] Fabrication of MEMS composite-polymer gas sensor arrays for electronic nose
    Pant, B. D.
    Kutnar, Mahesh
    Lakshmi, Subha
    Arora, Anil
    Prasad, Mahanth
    Sharma, Akshdeep
    Patel, Mohan
    Radhakrishnan, S.
    Dwivedi, V. K.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2007, 45 (04) : 321 - 325
  • [22] Erratum to: Development of an electrorheological chip and conducting polymer based sensor
    Xianzhou Zhang
    Weihua Li
    Weijia Wen
    Yanzhe Wu
    Gordon Wallace
    Frontiers of Mechanical Engineering in China, 2009, 4 (4): : 472 - 472
  • [23] Molecular modeling of polymer composite-analyte interactions in electronic nose sensors
    Shevade, AV
    Ryan, MA
    Homer, ML
    Manfreda, AM
    Zhou, H
    Manatt, KS
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3): : 84 - 91
  • [24] Development of electrorheological chip and conducting polymer-based sensor
    Zhang X.
    Li W.
    Wen W.
    Wu Y.
    Wallace G.
    Frontiers of Mechanical Engineering in China, 2009, 4 (4): : 393 - 396
  • [25] Detection of Off-Flavor in Catfish Using a Conducting Polymer Electronic-Nose Technology
    Wilson, Alphus D.
    Oberle, Charisse S.
    Oberle, Daniel F.
    SENSORS, 2013, 13 (12) : 15968 - 15984
  • [26] Mixed solid device based on conducting polymer composite and polymer electrolyte
    Neves, S
    Fonseca, CP
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (03) : 395 - 399
  • [27] Identification of Tobacco Types and Cigarette Brands Using an Electronic Nose Based on Conductive Polymer/Porphyrin Composite Sensors
    Esteves, C. Henrique A.
    Iglesias, Bernardo A.
    Ogawa, Takuji
    Araki, Koiti
    Hoehne, Lucelia
    Gruber, Jonas
    ACS OMEGA, 2018, 3 (06): : 6476 - 6482
  • [28] Polymer—Carbon Black Composite Sensors in an Electronic Nose for Air-Quality Monitoring
    M. A. Ryan
    A. V. Shevade
    H. Zhou
    M. L. Homer
    MRS Bulletin, 2004, 29 : 714 - 719
  • [29] A miniature electronic nose system based on an MWNT–polymer microsensor array and a low-power signal-processing chip
    Shih-Wen Chiu
    Hsiang-Chiu Wu
    Ting-I Chou
    Hsin Chen
    Kea-Tiong Tang
    Analytical and Bioanalytical Chemistry, 2014, 406 : 3985 - 3994
  • [30] Charge transfer in fullerene-conducting polymer composite: Electronic and excitonic properties
    Yoshino, K
    Tada, K
    Fujii, A
    Hosoda, K
    Kawabe, S
    Kajii, H
    Hirohata, M
    Hidayat, R
    Araki, H
    Zakhidov, AA
    Sugimoto, R
    Iyoda, M
    Ishikawa, M
    Masuda, T
    FULLERENE SCIENCE AND TECHNOLOGY, 1997, 5 (07): : 1359 - 1386