Quantitative blood flow estimation error due to the in-plane component of the flow with intravascular ultrasound

被引:0
|
作者
de Ana, FJ [1 ]
O'Donnell, M [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Previously we presented the flow estimation error introduced by in-plane flow using a slow-time FIR (finite impulse response) filter-bank method to quantitatively measure blood flow decorrelation through the image plane of an intravascular ultrasound (IVUS) imaging system. There exists a monotonic relationship between blood flow velocity and the normalized second moment of the slow-time spectrum for flow orthogonal to the imaging plane of a side-looking catheter array. However, in the presence of an in-plane flow component, this monotonic relationship changes due to a shift and spread of slow-time spectra. These two effects cause the normalized second moment to increase, resulting in flow overestimates. Applying appropriate tilts to slow-time signals, however. the slow-time spectrum shifts back to DC and the orthogonal estimation method can be used. We present a method to correct this overestimation and accurately estimate blood flow through the image plane in real-time. Independent simulations show that for blood flowing at angles between +/- 6 degrees and +/- 15 degrees at a speed of 30 cm/sec. flow would be overestimated by as much as 14.82% and 72.24% respectively using the direct filter-bank approach. However, this overestimation error can be corrected using the modified method presented here, reducing the estimation error by a factor of 29.9 and 34.64 for those angles respectively.
引用
收藏
页码:580 / 583
页数:4
相关论文
共 50 条
  • [21] ULTRASOUND BEAM FORMING FOR QUANTITATIVE ASSESSMENT OF BLOOD-FLOW
    EVANS, JM
    SKIDMORE, R
    WELLS, PNT
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1984, 5 (04): : 322 - 322
  • [22] In-plane elasticity controls the full dynamics of red blood cells in shear flow
    Mendez, Simon
    Abkarian, Manouk
    PHYSICAL REVIEW FLUIDS, 2018, 3 (10):
  • [23] Coronary blood flow imaging and volume flow quantitation with a intravascular ultrasound imaging catheter: Initial clinical experience
    Carlier, SG
    Ignacio, CE
    Cordova, R
    Li, WG
    Frits, M
    van der Steen, AFW
    Klaas, B
    Serruys, PW
    CIRCULATION, 1998, 98 (17) : 507 - 507
  • [24] Visualization of Anterior Segment Blood Flow with Plane-Wave Ultrasound
    Daly, Suzanne
    Urs, Raksha
    Lloyd, Harriet O.
    Coleman, D. Jackson
    Silverman, Ronald H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [25] An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound
    Wan, Li
    Yang, Natalie
    Hiew, Chee-Yan
    Schelleman, Anthony
    Johnson, Lynne
    May, Clive
    Bellomo, Rinaldo
    INTENSIVE CARE MEDICINE, 2008, 34 (08) : 1503 - 1510
  • [26] Coded ultrasound for blood flow estimation using subband processing
    Gran, Fredrik
    Udesen, Jesper
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [27] An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound
    Li Wan
    Natalie Yang
    Chee-Yan Hiew
    Anthony Schelleman
    Lynne Johnson
    Clive May
    Rinaldo Bellomo
    Intensive Care Medicine, 2008, 34 : 1503 - 1510
  • [28] ESTIMATION OF TOTAL HEPATIC BLOOD-FLOW BY DUPLEX ULTRASOUND
    LEEN, E
    COOKE, TG
    ANGERSON, WJ
    MCARDLE, CS
    GUT, 1992, 33 (09) : 1293 - 1294
  • [29] ESTIMATION OF TOTAL HEPATIC BLOOD-FLOW BY DUPLEX ULTRASOUND
    CARLISLE, KM
    HALLIWELL, M
    READ, AE
    WELLS, PNT
    GUT, 1992, 33 (01) : 92 - 97
  • [30] Coded ultrasound for blood flow estimation using subband processing
    Gran, Fredrik
    Udesen, Jesper
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (10) : 2211 - 2220