Validation of a flexible endoscopy simulator

被引:71
|
作者
Felsher, JJ
Olesevich, M
Farres, H
Rosen, M
Fanning, A
Dunkin, BJ
Marks, JM [1 ]
机构
[1] Case Western Reserve Univ, Dept Surg, Cleveland, OH 44106 USA
[2] Cleveland Clin Fdn, Minimally Invas Surg Ctr, Cleveland, OH 44195 USA
[3] Univ Miami, Sch Med, Dept Surg, Miami, FL 33152 USA
[4] Hillcrest Hosp, Mayfield Heights, OH 44124 USA
来源
AMERICAN JOURNAL OF SURGERY | 2005年 / 189卷 / 04期
关键词
simulators; colonoscopy; validation;
D O I
10.1016/j.amjsurg.2005.01.008
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Virtual reality (VR) simulation is a rapidly proliferating adjunct of surgical training. Numerous devices have evolved as educational tools in a variety of fields. Whether these tools can be used for validation of physicians' skills has yet to be determined. The objective of this study Was to determine whether the GI Mentor (Simbionix, Lod, Israel) flexible endoscopy simulator construct could distinguish experienced endoscopists from beginners. Methods: Seventy-five surgical attendings, fellows, and residents were recruited for participation in the study. Two cohorts were used and these groups were selected from 2 separate scientific sessions. Participants completed a standardized questionnaire documenting their endoscopic training and experience. Physicians subsequently were designated as experienced or beginner after their endoscopic training and experience were evaluated. All participants completed 1 of 2 colonoscopic simulations. The GI Mentor objectively evaluated performance on the basis of programmed data points, including the time to reach the cecum, the percentage of mucosa visualized, the completed polypectomy rate, the percentage of time spent in clear view through the lumen, the percentage of time that the patient was in pain, and overall efficiency. Results: In both simulations, experienced endoscopists were more efficient than beginners (.32%/s vs. .26%/s, P = .02; and .53%/s vs. .37%/s, P = .03) and achieved a greater polypectomy rate (78% vs. 43%, P = .03; and 87% vs. 48%, P = .01). Furthermore, experienced endoscopists visualized more of the colonic surface (86% vs. 82%, P = .02) and spent a greater proportion of the time in clear view of the lumen (55% vs. 47%, P = .05) than beginners completing the first simulation. In the second simulation, experienced participants reached the cecum more rapidly than beginners (175 vs. 262 s, P = .01). Conclusions: The GI Mentor VR colonoscopy construct appears valid. Significant performance differences were shown between the experienced and beginner cohorts. The beginner participants in this study were all physicians with some degree of endoscopic experience. Therefore, the GI Mentor distinguished endoscopists of varying experience and exposure. Further validation studies are needed to evaluate the breadth of programs inherent to this simulator and to determine whether if may be used in the future for qualification and certification purposes. (c) 2005 Excerpta Medica Inc. All rights reserved.
引用
收藏
页码:497 / 500
页数:4
相关论文
共 50 条
  • [41] Flexible Endoscopy in Small Animals
    Sum, Steffen
    Ward, Cynthia R.
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2009, 39 (05) : 881 - +
  • [42] FLEXIBLE GUIDE FOR PERORAL ENDOSCOPY
    ROGERS, BHG
    GASTROINTESTINAL ENDOSCOPY, 1982, 28 (03) : 193 - 195
  • [43] KNOT TYING AT FLEXIBLE ENDOSCOPY
    LAI, KC
    SWAIN, CP
    GONG, F
    RATANI, RS
    BROWN, G
    MILLS, T
    GUT, 1992, 33 (02) : S17 - S17
  • [44] The economic impact of flexible endoscopy
    J.J. O'Connor
    Surgical Endoscopy And Other Interventional Techniques, 2003, 17 : 998 - 998
  • [45] Flexible Airway Endoscopy in Children
    Hayden, Lystra
    Boyer, Debra
    Hysinger, Erik Bradford
    Moore, Paul E.
    Faro, Albert
    Wilson, Kevin C.
    Thomson, Carey C.
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2015, 12 (12) : 1873 - 1875
  • [46] Systematic validation of two instruments to evaluate technical skills in flexible bronchoscopy using a virtual reality simulator
    Davoudi, Mohsen
    Osann, Katherine
    Murgu, Septimiu
    Colt, Henri
    CHEST, 2006, 130 (04) : 166S - 166S
  • [47] Validation of the Madigan ESS simulator
    Weghorst, S
    Airola, C
    Oppenheimer, P
    MEDICINE MEETS VIRTUAL REALITY: ART, SCIENCE, TECHNOLOGY: HEALTHCARE (R)EVOLUTION TM, 1998, 50 : 399 - 405
  • [48] Validation of a thoracoscopic lobectomy simulator
    Tong, Betty C.
    Gustafson, Monica R.
    Balderson, Stafford S.
    D'Amico, Thomas A.
    Meyerson, Shari L.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (02) : 364 - 369
  • [49] Behavioral cloning for simulator validation
    Abbott, Robert G.
    ROBOCUP 2007: ROBOT SOCCER WORLD CUP XI, 2008, 5001 : 329 - 336
  • [50] Development and validation of a mastication simulator
    Woda, A.
    Mishellany-Dutour, A.
    Batier, L.
    Francois, O.
    Meunier, J-P.
    Reynaud, B.
    Alric, M.
    Peyron, M-A.
    JOURNAL OF BIOMECHANICS, 2010, 43 (09) : 1667 - 1673