Effect of the Method for Immobilizing Receptor Layer on the Analytical Characteristics of a Label-Free Electrochemical Immunosensor for the Determination of Measles Antibodies

被引:5
|
作者
Svalova, T. S. [1 ]
Malysheva, N. N. [1 ]
Bubekova, A. K. [1 ]
Saigushkina, A. A. [1 ]
Medvedeva, M. V. [1 ]
Kozitsina, A. N. [1 ]
机构
[1] Ural Fed Univ, Ekaterinburg 620002, Russia
关键词
electrografting; label-free immunosensor; measles antigen; covalent immobilization; GLASSY-CARBON SURFACES; COVALENT MODIFICATION; ANODIC-OXIDATION; BIOSENSORS; IMMUNOASSAY; ELECTRODES; STEEL; GOLD;
D O I
10.1134/S106193482002015X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect of the method of immobilization of receptor layer on the analytical characteristics of label-free electrochemical immunosensors for determining antibodies to the measles virus is estimated. The receptor layer bearing the measles antigen was immobilized by dropping a model suspension on the surface of a glassy-carbon electrode, followed by drying in air and covalent crosslinking by electrografting of p-nitrophenyldiazonium chloride using glutaraldehyde as a crosslinking agent. The dependences of the peak current of the mediator system on the concentration of measles antibodies in model suspensions are linear and described by the equations I = -(28 +/- 1)c(at) - (30 +/- 4) and I = -(19 +/- 2)c(at) - (15 +/- 5) for the covalent immobilization and drop deposition of the receptor layer, respectively. Immobilization of the bioreceptor by covalent crosslinking does not lead to a significant improvement in the sensitivity of the determination; however, it expands the linear concentration range tenfold and decreases the total duration of the immunoassay procedure to 20 min with respect to the immunosensor with a drop-immobilized antigen.
引用
收藏
页码:254 / 261
页数:8
相关论文
共 42 条
  • [31] Label-free electrochemical immunosensor based on K3[Fe(CN)6] as signal for facile and sensitive determination of tumor necrosis factor-alpha
    Weng, Shaohuang
    Chen, Min
    Zhao, Chengfei
    Liu, Ailin
    Lin, Liqing
    Liu, Qicai
    Lin, Jianhua
    Lin, Xinhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 184 : 1 - 7
  • [32] 3D porous CS-AuNPs-PEDOT-PB nanocomposite cryogel for highly sensitive label-free electrochemical immunosensor for carcinoembryonic antigen determination
    Choosang, Jittima
    Khumngern, Suntisak
    Nontipichet, Natha
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    MICROCHEMICAL JOURNAL, 2023, 187
  • [33] A label-free biosensor based on graphene and reduced graphene oxide dual-layer for electrochemical determination of beta-amyloid biomarkers
    Sethi, Jagriti
    Van Bulck, Michiel
    Suhail, Ahmed
    Safarzadeh, Mina
    Perez-Castillo, Ana
    Pan, Genhua
    MICROCHIMICA ACTA, 2020, 187 (05)
  • [34] A label-free biosensor based on graphene and reduced graphene oxide dual-layer for electrochemical determination of beta-amyloid biomarkers
    Jagriti Sethi
    Michiel Van Bulck
    Ahmed Suhail
    Mina Safarzadeh
    Ana Perez-Castillo
    Genhua Pan
    Microchimica Acta, 2020, 187
  • [35] Label-free electrochemical immunosensor based on multi-functional gold nanoparticles-polydopamine-thionine-graphene oxide nanocomposites film for determination of alpha-fetoprotein
    Peng, Hua-Ping
    Hu, Yan
    Liu, Ai-Lin
    Chen, Wei
    Lin, Xin-Hua
    Yu, Xiang-Bin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 712 : 89 - 95
  • [36] Correction to: A label-free biosensor based on graphene and reduced graphene oxide dual-layer for electrochemical determination of beta-amyloid biomarkers
    Jagriti Sethi
    Michiel Van Bulck
    Ahmed Suhail
    Mina Safarzadeh
    Ana Perez-Castillo
    Genhua Pan
    Microchimica Acta, 2020, 187
  • [37] A "Clickable" Electrodeposited Polymer Films Based on 3-ethynylthiophene for the Covalent Immobilization of Proteins. Application to a Label-free Electrochemical Immunosensor for Escherichia Coli and Staphylococcus Aureus Determination
    Svalova, T. S.
    Medvedeva, M., V
    Kozitsina, A. N.
    ELECTROANALYSIS, 2021, 33 (12) : 2469 - 2475
  • [38] Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
    Aydin, Elif Burcu
    Aydin, Muhammet
    Sezginturk, Mustafa Kemal
    TALANTA, 2019, 200 : 387 - 397
  • [39] Novel Label-Free Electrochemical Impedance Immunosensor Using a Three-Dimensional Flower-Shaped Gold Nanoparticle@Molybdenum(IV) Sulfide/Graphene Composite for the Ultrasensitive Determination of Procalcitonin
    Lv, Qian
    Liu, Haixin
    Chen, Longsheng
    ANALYTICAL LETTERS, 2024, 57 (04) : 653 - 664
  • [40] A label-free biosensor based on graphene and reduced graphene oxide dual-layer for electrochemical determination of beta-amyloid biomarkers (vol 187, 288, 2020)
    Sethi, Jagriti
    Van Bulck, Michiel
    Suhail, Ahmed
    Safarzadeh, Mina
    Perez-Castillo, Ana
    Pan, Genhua
    MICROCHIMICA ACTA, 2020, 187 (06)