Introduction: The purpose of this investigation was to evaluate the dentoalveolar and skeletal cephalometric changes produced by headgear (HG) biteplane and bionator appliances in subjects with Class II Division 1 malocclusion. Methods: The sample comprised 60 patients with Class II Division 1 malocclusion; 30 (15 boys, 15 girls; mean age, 10.02 years) were treated with the HG biteplane for a mean period of 1.78 years, and 30 (15 boys, 15 girls; mean age, 10.35 years) were treated with a bionator for a mean period of 1.52 years. For comparison, a control group of 30 untreated Class 11 children (15 boys, 15 girls) with an initial mean age of 10.02 years, followed for 1.48 years, was established. Lateral cephalometric headfilms were obtained at the beginning and at the end of the treatment or observation period. Results: The results showed that forward growth of the maxilla was restricted in the HG biteplane group. Bionator treatment, however, produced a statistically significant increase in mandibular protrusion. Both appliances provided increases in total mandibular and ramus lengths. There were no statistically significant differences in craniofacial growth direction. The mandibular incisors were tipped labially with bionator treatment and lingually in the HG biteplane group. The maxillary incisors were retruded with both appliances; there also were a significant increase in mandibular posterior dentoalveolar height and a restriction in the vertical development of the maxillary molars. Conclusions: Class II treatment with HG biteplane and bionator appliances is efficient over the short term, with pronounced dentoalveolar movements and smaller but still significant skeletal effects. The stability of these results should be examined in a long-term study.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [21] The correction of class II, division 1 malocclusion with bionator headgear combination appliance
    Mao Jing
    Zhao Hong
    Current Medical Science, 1997, 17 (4) : 254 - 256
  • [22] Effects of cervical headgear and fixed appliances on the space available for maxillary second molars
    Piva, LM
    Brito, HHA
    Leite, HR
    O'Reilly, M
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (03) : 366 - 371
  • [23] Orthodontists' and parents' perception of facial profile following bionator and headgear therapies.
    Ossi, AR
    Keeling, SD
    King, GJ
    Wheeler, TT
    McGorray, SP
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2616 - 2616
  • [24] Bionator与Headgear联用的实用理论与临床应用
    毛靖
    彭友俭
    临床口腔医学杂志, 2001, (03) : 197 - 198
  • [26] Cephalometric evaluation of Class II malocclusion treatment with cervical headgear and mandibular fixed appliances
    Freitas, M. R.
    Lima, D. V.
    Freitas, K. M. S.
    Janson, G.
    Henriques, J. F. C.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (05) : 477 - 482
  • [27] Comparative Study of the Bionator and Multi-P Appliances in the Treatment of ClassII Malocclusion: a Randomized Cephalometric Trial
    Oshagh, Morteza
    Memarpour, Mahtab
    Najafi, Hooman Zarif
    Heidari, Somayeh
    GALEN MEDICAL JOURNAL, 2013, 2 (01): : 1 - 11
  • [28] Comparison of protraction headgear response with banded and bonded appliances
    Ngan, P
    Cheung, E
    Hagg, U
    Yiu, C
    Wei, S
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 117 - 117
  • [29] Compliance monitor for use with removable orthodontic headgear appliances
    Kyriacou, PA
    Jones, DP
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) : 57 - 60
  • [30] Compliance monitor for use with removable orthodontic headgear appliances
    P. A. Kyriacou
    D. P. Jones
    Medical and Biological Engineering and Computing, 1997, 35 : 57 - 60